Timber-glass composite shear wall elements were manufactured with different adhesives. The elements were 1200×2400 mm in size. 12 single pane elements and one element with an insulation glass unit (IGU) were manufactured. The load bearing glass pane was in all cases made from 10 mm float glass. The elements were tested in various loading conditions, involving pure vertical load and different combinations of in-plane shear and vertical loading. The test results show that the influence of the adhesive chosen on the ultimate (buckling) load is only of minor importance. This was also confirmed by finite element analyses.