Hydrogen gas has high potential to reduce greenhouse gas emissions and facilitate large-scale decarbonization in multiple sectors. Its consumption is expected to increase significantly in the coming years, making it crucial to build new sustainable and safe infrastructure for hydrogen storage and transport. High‑strength carbon steels (HSCS) are being considered as potential candidate materials for these applications. In addition to being cost‑effective, these steels offer favourable mechanical properties that would enable their use at higher operating pressures and allow for reduced wall thickness in pipeline and pressure‑vessel structures. However, a major challenge is the degradation of important mechanical properties due to atomic hydrogen-metal interaction through a phenomenon known as hydrogen embrittlement (HE), to which HSCS are particularly susceptible. Thus, evaluation of the performance of HSCS in hydrogen environments under relevant service conditions is crucial for a faster implementation of hydrogen gas in various technologies. To achieve this, testing must closely reproduce service conditions.
Hydrogen gas testing at high pressure is the best approach for evaluating influence of hydrogen on mechanical properties of metals close to service conditions. High-pressure in-situ autoclave testing is the most reliable testing method enabling fracture mechanics measurements to quantify crack initiation and propagation rates, predict mechanical integrity and provide design data for safe hydrogen gas infrastructure under relevant service conditions. However, autoclave testing is a costly and demanding method due to several factors, including strict safety requirements and limited access, as a small number of specialized laboratories worldwide can perform such test. The hollow-specimen method (HSM) is an alternative, practical and accessible technique for in-situ hydrogen gas testing at high-pressures under controlled pressurized environments. The advantage of HSM is that testing can be conducted at significantly lower costs and reduced risks compared to autoclave testing. However, one major drawback is that HSM cannot be used to perform fracture mechanics testing, but it is well suited for evaluating the tensile behaviour through slow strain rate testing (SSRT) as well as fatigue performance under cyclic loading conditions.
In this work, two HSCS steels, A516 Gr70 and A537 Cl2, have been studied using the HSM at 200 bar and room temperature conditions. These steels exhibit ultimate tensile strengths (UTS) in the range of 530 to 650 MPa and are characterized by ferritic–pearlitic and ferritic-bainitic microstructures, respectively. The tensile behaviour was evaluated with SSRT, allowing time for hydrogen to diffuse and interact with metal defects. The fatigue life was evaluated by means of low cycle fatigue (LCF), under strain-controlled testing. After testing, fractographic analysis with scanning electron microscope (SEM) was conducted to identify features associated with HE on the fracture surfaces. Additionally, thermal desorption spectroscopy coupled with mass spectrometry (TDS‑MS) was employed to quantify the hydrogen concentration present in the specimens after failure. The combined data from these techniques are essential for assessing HE mechanisms active in the evaluated steels. The A537 Cl2 was evaluated using autoclave fatigue crack growth (FCGR) testing to compare the results with the ones obtained from LCF.
Exposure to high-pressure hydrogen gas led to a small reduction in tensile toughness and ductility of the evaluated steels. Influence of strain rate was examined, revealing that lower strain rates activate different failure mechanisms. Heat treatment effects were also assessed through SSRT, showing that in A516 Gr70, stresses and hard phases located along the centreline contributed to premature failure in hydrogen environments. After heat treatment, this behaviour was no longer observed, highlighting how hydrogen interacts with defects and non‑homogeneous microstructural features. In contrast, the LCF tests demonstrated a marked reduction in fatigue life under the tested conditions, with the severity increasing at higher strain amplitudes. Fatigue life was defined as the number of cycles until a pressure drop occurred, indicating crack growth from the inner to the outer surface. TDS-MS confirmed hydrogen uptake after SSRT and minor uptake after LCF, suggesting localized interaction at the crack tip. FCGR tests revealed one order of magnitude faster crack growth rate in hydrogen compared to air, and the resulting propagation curves were consistent with the fatigue design curves.
The work in this thesis highlights the use of in-situ high-pressure hydrogen gas testing methods for assessing the influence of hydrogen on the tensile and fatigue properties and the respective resistance to hydrogen induced damage/cracking of pressure vessels in service condition environments.
Place, publisher, year, edition, pages
Luleå: Luleå University of Technology, 2026
Series
Licentiate thesis / Luleå University of Technology, ISSN 1402-1757
Keywords
Hydrogen gas pipelines and pressure vessels, Hydrogen embrittlement, Hollow specimen method, Autoclave testing, Slow strain rate testing, Low cycle fatigue, Fatigue crack growth test
National Category
Metallurgy and Metallic Materials
Research subject
Engineering Materials
Identifiers
urn:nbn:se:ltu:diva-117234 (URN)978-91-8142-059-3 (ISBN)978-91-8142-060-9 (ISBN)
Presentation
2026-06-15, E243, Luleå University of Technology, Luleå, 13:00 (English)
Opponent
Supervisors
Funder
Swedish Agency for Economic and Regional Growth, 20358499
2026-04-212026-04-212026-05-25Bibliographically approved