Digitala Vetenskapliga Arkivet

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Evaluation of a Spray Tower Absorber for Carbon Capture from Heavy-Duty Vehicles
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Chemical Engineering.
2025 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesisAlternative title
Utvärdering av ett Spraytorn för Koldioxiduppfångning från Tunga Fordon (Swedish)
Abstract [sv]

Detta arbete utvärderade en spraykolonn med monoetanolamin (MEA) för mobilt koldioxid infångning (MCC) från avgaser från tunga dieselfordon genom att utveckla en ”rate-based” Aspen Plus-modell och inkorporera den i en systemmodell representativ för en modul bakom förarhytten på en lastbil. Absorptionskolonnen emulerades med en RadFrac-enhet där fyllkropparna ändrades för att efterlikna spray-droppar. ELECNRTL-termodynamik och diskretisering av vätskefasens film användes. Simuleringarna omfattade 18 motordriftpunkter och riktade in sig på specifika energiförbrukningen i återkokaren (SRD) i nivåerna 4, 7 och 10 MJ/kg CO2. 

Över hela intervallet av operationspunkter  ökade infångningsgraden medförhållandet mellan vätska och gas (L/G) och med avgasernas CO2-halt, men avkastningen avtog vid högre SRD och planade ut när filmbundna begränsningar dominerade. Högre avgasmassflöde reducerade infångningen vid givet SRD genom kortare uppehållstid. I många fall kunde modellen inte nå SRD under 5 MJ/kg CO2, eftersom låg uppfångning per rundtur krävde uppvärmning av stora flöden och ökade därmed energianvändningen. 

Givet en absorbervolym förenlig med MCC:s installationsutrymme gav spraykonfigurationen lägre infångning än en kolonn med packad bädd av samma volym, om än med försumbart tryckfall på gassidan. Under ett strikt antagande att endast spillvärme från motorn kunde användas motsvarande stationärt driftfall vid 1500 rpm och 120 °C var uppnådd infångning av CO2 måttlig (32–45 %), begränsad av tillgänglig termisk budget. 

Studien indikerade att metoden effektivt möjliggjorde sondering av drifttrender och systemavvägningar, men att viktiga begränsningar kvarstod: dropparnas dynamik och ytarea beror på flera faktorer som inte kunde kontrolleras i modellen. Modellen byggde på justerade massöverföringsfaktorer, vilket minskade den prediktiva säkerheten utanför kalibreringsintervallet. Slutsatsen var att enstegs spraykolonner sannolikt inte uppfyller krav på infångning och energi för fordonstillämpning utan flerstegslayouter, optimering av droppfältet och/eller regenerering under 100 °C (t.ex. vakuum). Rekommenderad framtida forskning omfattade validering mot oberoende pilotdata samt vidareutveckling mot detaljerade numeriska eller CFD-stödda modeller samdesignade med värmeintegrationsbegränsningar. 

Abstract [en]

This thesis assessed a spray-tower monoethanolamine (MEA) absorber for mobile carbon capture from the exhaust of heavy-duty diesel vehicles by developing a rate-based Aspen Plus model and introducing it in a system model representative of a behind-cab module. The absorber was emulated by a RadFrac packed-column base configured as a high-void-fraction droplet field with ELECNRTL thermodynamics and liquid-film discretization. Simulations covered 18 engine operating points and targeted specific reboiler duties (SRD) of 4, 7, and 10 MJ/kg CO2. 

Across the map, the CO2 capture rate increased with liquid-to-gas ratio and with exhaust CO2 fraction, but exhibited diminishing returns at higher SRD and plateaued as film-side limitations dominated, and likely som problems with the models of prediciting high capture rates. Higher exhaust mass flow reduced capture at a given SRD due to shorter residence time. In many cases the model did not reach SRD below 5 MJ/kg CO2 because low per-pass capture required heating large solvent flows, inflating normalized duty.

 For an absorber volume compatible with the MCC setup, the spray configuration achieved lower capture than a packed bed of equal volume, albeit with negligible gas-side pressure drop. The capture rate reached up to 90 % for very low gas flow rates, but for parts of the engine map with higher gas flow rate the capture rate was significantly lower. Under a waste-heat-only constraint representative of stationary operation at 1500 rpm with 120 ◦C coolant, achievable capture was modest (32–45 %), limited by the available thermal budget. 

The study indicated that while the modelling approach enabled efficient scoping of operating trends and system-level trade-offs, important limitations remained: the approach did not resolve droplet dynamics or nozzle-dependent interfacial area, and relied on tuned mass- transfer factors, reducing predictive confidence outside the calibration range. Consequently, single-stage spray towers appeared unlikely to meet on-vehicle capture and energy targets without multi-stage arrangements, droplet-field optimization, and/or sub-100 °C regenera- tion (e.g. vacuum). Future work should validate against independent pilot data and ad- vance toward droplet-resolved or CFD-supported models co-designed with heat-integration constraints. 

Place, publisher, year, edition, pages
2025.
Series
TRITA-CBH-GRU ; 2025:293
Keywords [en]
Carbon Capture, Spray Tower, Modelling, Aspen Plus, Transportation Sector, Droplet Interaction
Keywords [sv]
Koldioxiduppfångning, Spraytorn, Modellering, Aspen Plus, Transportsektor, Droppinteraktion
National Category
Chemical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-369006OAI: oai:DiVA.org:kth-369006DiVA, id: diva2:1992054
External cooperation
Scania CV AB
Subject / course
Chemical Engineering
Educational program
Degree of Master - Chemical Engineering for Energy and Environment
Examiners
Available from: 2025-08-26 Created: 2025-08-26

Open Access in DiVA

fulltext(4014 kB)343 downloads
File information
File name FULLTEXT01.pdfFile size 4014 kBChecksum SHA-512
84dabe62a6e7b6cf5826dd0c47d33c2294b1914e3f3b6ec23fde469c11a5f1d5afd0e6bde9bb216e055a3bea26224bf5a3e33de23b7fa6116aeabb867aad6adf
Type fulltextMimetype application/pdf

By organisation
Chemical Engineering
Chemical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 346 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1261 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf