Abstract [en]
Geometric parametrization for enhanced speech intelligibility involves designing the architecture in order to highlight acoustic parameters that give rise to communicative spaces with good acoustic quality. In current planning, sound absorption is used in a wide range to reduce noise pollution. However, through architectural design, it is possible to control the spread of acoustics in a more fundamental manner. This approach is being explored for its effect on underground train stations. This study aims to investigate how parametric design has an impact on speech intelligibility. The goal is to describe the effects that different tilts in angle of the walls, along the train station´s length, have on the Speech transmission index.
A theoretical, empirical and practical investigation is conducted, involving the collection of data through previous research and practical observations from an experienced acoustics consultant, as well as calculations of a digital model performed independently. A case study is carried out to measure real background noise levels, which serve as the basis for the software simulations and calculations. The results display the impact of geometric parameterization on speech intelligibility, nevertheless highlighting the necessity of a low noise level of the background environment in order to achieve a considerable effect. General measurements for the effects that the change in angle of the walls have on Speech transmission index are presented and emphasized as specifically tailored to the conditions characterized by the studied model.
Two central acoustical parameters are studied - background noise levels and reverberation - and are identified as paramount to treat in order to achieve a good speech intelligibility in underground train stations. Suggestions of further research are provided and include alternative methods to address how speech intelligibility can be improved by examining the impact of other spatial dimensions and architectural formations.
Place, publisher, year, edition, pages
2025. , p. 57
Keywords [sv]
arkitektur, akustik, taluppfattbarhet, tågstationer under mark, speech transmission index, STI, speech intelligibility, parametrisk design, parametric design
National Category
Architectural Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-114361OAI: oai:DiVA.org:ltu-114361DiVA, id: diva2:1990240
External cooperation
Brekke & Strand Akustik AB
Subject / course
Student thesis, at least 30 credits
Educational program
Architectural Engineering, master's level
Presentation
2025-06-05, Laboratorievägen 14, Luleå, 10:15 (Swedish)
Supervisors
Examiners
2025-08-282025-08-192025-10-21Bibliographically approved