Advancements Towards Contactless Biomedical Microwave Applications
Mälardalen University, School of Innovation, Design and Engineering, Embedded Systems. (Medical Health Engineering)ORCID iD: 0000-0003-3248-2529
2025 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Medical Microwave Imaging (MWI) has been the subject of ongoing research to establish it as a complementary method to conventional clinical imaging modalities. Especially the field of breast cancer detection has seen significant progress in recent years. However, low signal quality remains a persistent challenge, primarily due to spurious signal components, commonly referred to as clutter, that originate within the imaging domain but do not convey information about the internal structure of the breast. Existing strategies to reduce clutter and thereby increase the detectability of a tumor include the application of coupling liquids or contacting antennas, which often fail to meet clinical requirements regarding hygiene, patient comfort, and practical applicability.

To address these limitations, in this thesis, we explore alternative approaches to mitigate clutter in non-contacting, air-based MWI systems aimed at improving clinical feasibility. Specifically, the effect of different field polarizations is being analyzed regarding their potential to reduce unwanted interactions at the air-skin interface. Furthermore, a transmitting field applicator is introduced that leverages reactive near-field interactions for efficient power transmission into the load without the need for direct contact. A mathematical framework based on the boundary element surface method is developed, enabling efficient integration of the proposed strategies into a model-based reconstruction pipeline. In summary, a non-contacting, air-based hardware concept for practical and patient-friendly application is presented together with a computational method for efficient numerical modeling of the system. The contributions made in this thesis advance MWI further towards its potential role as a clinically viable technique for breast cancer detection.

Place, publisher, year, edition, pages
Västerås: Mälardalen University , 2025.
Series
Mälardalen University Press Dissertations, ISSN 1651-4238 ; 437
National Category
Medical Imaging
Research subject
Electronics
Identifiers
URN: urn:nbn:se:mdh:diva-73046ISBN: 978-91-7485-716-0 (print)OAI: oai:DiVA.org:mdh-73046DiVA, id: diva2:1990134
Public defence
2025-10-10, Paros, Mälardalens universitet, Västerås, 09:15 (English)
Opponent
Supervisors
Available from: 2025-08-21 Created: 2025-08-19 Last updated: 2025-10-10Bibliographically approved
List of papers
1. Retro-Modelling Technique for Permittivity Measurements in the Range from 2.2 to 2.6 GHz for Medical Applications
Open this publication in new window or tab >>Retro-Modelling Technique for Permittivity Measurements in the Range from 2.2 to 2.6 GHz for Medical Applications
2021 (English)In: 2021 IEEE International Conference on Antenna Measurements and Applications 2021 IEEE CAMA, Antibes Juan-les-pins, France: Institute of Electrical and Electronics Engineers (IEEE) , 2021, p. 220-225Conference paper, Published paper (Refereed)
Abstract [en]

In this study we present a permittivity measurement technique based on retro-modelling of a resonant cavity in the frequency range from 2.2 to 2.6 GHz that allows for a more arbitrary sample shape than traditional cavity perturbation techniques. It is shown that the resolution of the retro-modelling technique can be improved if the invoked modes in the sample and in the surrounding cavity space are of different type or indexation, a condition that must clearly be avoided in classical perturbation techniques. The measurement method was applied to a ceramic sample of unknown permittivity which was retro-modelled to "0 = 19.35 and   = 0.009 S/m with a remaining combined error of geometry and permittivity deviations between measurement and simulation of <0.1% in frequency and 22% in Q-value at the target resonance. This technique will allow us to identify suitable dielectric materials to improve the feed efficiency of our magnetic field applicator which is currently being developed for microwave breast cancer detection.

Place, publisher, year, edition, pages
Antibes Juan-les-pins, France: Institute of Electrical and Electronics Engineers (IEEE), 2021
Keywords
permittivity, measurement, ceramic, retromodelling, dielectric
National Category
Engineering and Technology Computer Systems
Identifiers
urn:nbn:se:mdh:diva-56768 (URN)10.1109/CAMA49227.2021.9703643 (DOI)001416160800058 ()2-s2.0-85126736092 (Scopus ID)9781728196978 (ISBN)
Conference
2021 IEEE International Conference on Antenna Measurements and Applications 2021 IEEE CAMA, 15 Nov 2021, Antibes Juan-les-pins, France
Projects
ESS-H - Embedded Sensor Systems for Health Research Profile
Available from: 2021-12-16 Created: 2021-12-16 Last updated: 2026-06-15Bibliographically approved
2. Further Developments of a Magnetic Near-Field Applicator for Microwave Imaging in Air
Open this publication in new window or tab >>Further Developments of a Magnetic Near-Field Applicator for Microwave Imaging in Air
2023 (English)In: IEEE Conference on Antenna Measurements and Applications, CAMA, Institute of Electrical and Electronics Engineers (IEEE) , 2023, p. 666-671Conference paper, Published paper (Refereed)
Abstract [en]

In this paper, we present the latest design of a magnetic field applicator designed to expose a dielectric body to electromagnetic microwave radiation by means of a magnetic near-field for microwave imaging purposes. Numerical simulations show that unwanted surface waves created from electric fringing fields of the applicator can be separated from the desired fields inside the breast due to their different polarizations. The applicator working principle is demonstrated in an experimental measurement setup with three different tissue-mimicking loads. A propagating electromagnetic wave is invoked directly inside the load based on its dielectric properties, leading to a decreasing reflection coefficient with increasing load permittivity, which could be verified in numerical simulations and experimental measurements.

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers (IEEE), 2023
Series
IEEE Conference on Antenna Measurements & Applications, ISSN 2474-1760
Keywords
breast, cancer, electromagnetics, imaging, magnetic, microwave, near-field, tumor
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:mdh:diva-65681 (URN)10.1109/CAMA57522.2023.10352912 (DOI)2-s2.0-85182259600 (Scopus ID)9798350323047 (ISBN)
Conference
2023 IEEE Conference on Antenna Measurements and Applications, CAMA 2023, Genoa, 15 November 2023 through 17 November 2023
Available from: 2024-01-24 Created: 2024-01-24 Last updated: 2026-02-27Bibliographically approved
3. Evanescent Field Applicator for Contactless Microwave Breast Diagnostics in Air
Open this publication in new window or tab >>Evanescent Field Applicator for Contactless Microwave Breast Diagnostics in Air
2024 (English)In: IEEE Transactions on Antennas and Propagation, ISSN 0018-926X, E-ISSN 1558-2221, Vol. 72, no 7, p. 5489-5501Article in journal (Refereed) Published
Abstract [en]

In this article, we present an air-based approach to irradiate the female breast with electromagnetic microwave radiation by means of contactless evanescent near-field coupling for medical applications. A suitable transducer, so-called applicator, is presented, designed to create a TE-polarized evanescent field at approximately 4 GHz, reducing stray radiation and other unwanted first-order interactions at the breast surface without the need for a dielectric bolus liquid. Initial numerical investigations showed that the applicator setup achieves a 20-dB higher signal-to-clutter ratio (SCR) than a comparable bolus-based setup when applied to a simple high-adipose breast phantom. In the case of a low-adipose test load, the SCR could not be readily attributed to the presence of a tumor, yet it was found that under realistic conditions, the applicator setup achieves a significantly higher power transmission Effectiveness (EFF) into the load of up to 80% compared to the bolus-based setup that achieved less than 0.1% EFF. Experimental measurements of the applicator show a change of resonance frequency of less than 2% for load permittivities ranging from 1 to 80, enabling the applicator to be used for a wide span of patient-specific dielectric breast properties.

Place, publisher, year, edition, pages
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 2024
Keywords
Couplings, Dielectrics, Breast, Applicators, Surface waves, Microwave antennas, Optical waveguides, Antennas, cancer, evanescent waves, imaging, magnetic fields, microwave devices, microwave imaging (MWI), near fields, transmitting antennas
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:mdh:diva-69420 (URN)10.1109/TAP.2024.3405178 (DOI)001271317200015 ()2-s2.0-85194829761 (Scopus ID)
Available from: 2024-12-11 Created: 2024-12-11 Last updated: 2025-10-10Bibliographically approved
4. Utilizing Spherical Resonances for Microwave Breast Cancer Detection
Open this publication in new window or tab >>Utilizing Spherical Resonances for Microwave Breast Cancer Detection
2023 (English)In: 17th European Conference on Antennas and Propagation, EuCAP 2023, Institute of Electrical and Electronics Engineers (IEEE) , 2023Conference paper, Published paper (Refereed)
Abstract [en]

In this paper, we investigate if external resonances created at a spherical tumor model can be utilized to increase the contrast between the tumor and background field in a simple microwave breast imaging scenario. Numerical simulations are being performed for two cases, low-adipose and high-adipose average breast tissue, exhibiting high and low permittivity and dielectric losses, respectively. The electric field is probed along the breast surface with and without a spherical tumor model present, and the relative tumor signal with respect to the background field is separated into a surface-normal and surface-parallel component. It is shown that in the high-adipose case, an external spherical resonance is created at the tumor, whereas no clear resonance occurs in the low-adipose case. In both cases is the contrast between the tumor signal and the background field stronger in the surface-normal than in the surface-parallel component. The external tumor resonance could directly be observed in the high-adipose case as a decrease of field strength close to the tumor if placed in close proximity to the breast surface.

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers (IEEE), 2023
Series
Proceedings of the European Conference on Antennas and Propagation, ISSN 2164-3342
Keywords
breast, cancer, diffraction, electromagnetics, imaging, microwave, tumor, Dielectric losses, Diseases, Electric fields, Medical imaging, Spheres, Background field, Breast cancer detection, External resonance, Parallel component, Simple++, Surface normals, Tumor models, Tumors
National Category
Cancer and Oncology
Identifiers
urn:nbn:se:mdh:diva-63669 (URN)10.23919/EuCAP57121.2023.10133221 (DOI)001023316901084 ()2-s2.0-85162256916 (Scopus ID)9788831299077 (ISBN)
Conference
17th European Conference on Antennas and Propagation, EuCAP 2023, 26-31 March 2023, Florence, Italy
Available from: 2023-06-28 Created: 2023-06-28 Last updated: 2026-02-25Bibliographically approved
5. Estimating the Signal Strength for Microwave Breast Cancer Detection with a Magnetic Near-Field Applicator in Air
Open this publication in new window or tab >>Estimating the Signal Strength for Microwave Breast Cancer Detection with a Magnetic Near-Field Applicator in Air
2024 (English)In: 18th European Conference on Antennas and Propagation, EuCAP 2024, Institute of Electrical and Electronics Engineers Inc. , 2024Conference paper, Published paper (Refereed)
Abstract [en]

In this paper, we present a numerical simulation scenario to estimate the signal strength of a tumor in a microwave detection scenario containing a magnetic near-field applicator and a quarter-wave dipole as transmitter and receiver, respectively. Two different receiver orientations are tested on two different breast phantoms representing high-adipose and low-adipose bulk breast tissue. The tumor signal strength is estimated by subtracting the received signals acquired with and without a tumor being present. The results indicate that in the horizontally aligned receiver case, the presence of a tumor can be estimated from the receiver positions exhibiting the highest difference signals. The strongest difference signals however do not occur at the frequency of operation but below. The other cases are not conclusive, but a stronger tumor signal was received with the horizontally aligned receiver than with the vertically aligned one throughout.

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers Inc., 2024
Keywords
Antennas, Breast cancer, Imaging, Microwave devices, Microwave imaging, Near fields, Applicators, Dipole antennas, Diseases, Medical imaging, Microwave antennas, Signal receivers, Breast cancer detection, Magnetic near field, Microwave detection, Quarter waves, Receiver orientation, Signal strengths, Transmitter and receiver, Tumors
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:mdh:diva-66615 (URN)10.23919/EuCAP60739.2024.10501586 (DOI)001215536203017 ()2-s2.0-85192465333 (Scopus ID)9788831299091 (ISBN)
Conference
18th European Conference on Antennas and Propagation, EuCAP, Glasgow, March 17-22 2024
Note

Conference code: 199134

Available from: 2024-05-16 Created: 2024-05-16 Last updated: 2025-10-10Bibliographically approved
6. Two-Step Equivalent Sources Method for Electromagnetic Near-Field Calculations at Microwave Frequencies
Open this publication in new window or tab >>Two-Step Equivalent Sources Method for Electromagnetic Near-Field Calculations at Microwave Frequencies
2025 (English)In: IEEE Transactions on Magnetics, ISSN 0018-9464, E-ISSN 1941-0069, Vol. 61, no 6, article id 7000709Article in journal (Refereed) Published
Abstract [en]

In this paper, we propose a two-step equivalent sources method (ESM) to calculate the total electric and magnetic fields in the vicinity of a dielectric scatterer located in the near-field of a radiating Hertz dipole. The electric component is determined by calculating equivalent bounded surface charges at the boundary of the dielectric object, resulting in a reduced linear system of equations compared to other ESMs that require the whole volume to be discretized. Singularities in the electric field of the surface point charges are avoided by introducing uniformly charged triangular sheets. A second set of equivalent sources is derived to account for the magnetic field. While these fictitious magnetic field sources are distributed over the whole volume of the object, no further matrix inversion is required as will be presented herein. Even with a relatively coarse discretization of 284 surface and 552 volume elements, an error of less than 0.2% with respect to a reference solution obtained from a finite element method is achieved. The small error, together with the significantly reduced computation time, demonstrate the high accuracy and efficiency of the proposed method. 

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers (IEEE), 2025
Keywords
Boundary element source method, Dual mesh, Hertz dipole, Microwave imaging
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:mdh:diva-71225 (URN)10.1109/tmag.2025.3556521 (DOI)001499319000008 ()2-s2.0-105002143374 (Scopus ID)
Note

Part 2, June

Available from: 2025-04-16 Created: 2025-04-16 Last updated: 2026-07-20Bibliographically approved

Open Access in DiVA

fulltext(69269 kB)184 downloads
File information
File name FULLTEXT02.pdfFile size 69269 kBChecksum SHA-512
d4c2db939708b2bd27786d0b41da6a64a3b9971b8459b8a221b51c19ef077950040d94cebc3d4fa62cc93303ede3d3e29475b00f01f1fada130b0ad52d9251bb
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Salomon, Christoph
By organisation
Embedded Systems
Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 185 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 1351 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf