Judging X-ray Source Performance in CT Applications
Uppsala University, Disciplinary Domain of Science and Technology, Physics, Department of Physics and Astronomy.
2025 (English)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

The performance of the X-ray source plays a critical role in the quality of a computed tomography (CT) imaging system. In the pursuit of standardizing source performance evaluation in CT, this work identifies and develops unique methods and metrics designed to target X-ray source performance independently of confounding system effects—an important consideration for high-resolution sources that may outperform other system components, such as rotation stages. These methods and metrics are validated through simulations and applied to assess and compare two X-ray sources. To quantify achievable resolution, a copper wire with a diameter of 120 μm is scanned without rotation to reduce interference from other system components. By analysing the extent of edge blurring in the reconstruction, the in-plane modulation transfer function (MTF) is obtained. Additionally, two signal-to-noise ratio (SNR) metrics are introduced, combining MTF and noise power spectrum (NPS) data to estimate the smallest detectable feature size within an in-plane slice of the reconstructed volume. Simulation results demonstrate a strong correlation between one of these metrics and human visual assessment. Experimental results show that both sources can achieve sub-micron resolution, with one consistently outperforming the other in this regard. Although the proposed SNR metrics have not yet been experimentally validated or applied, they show potential for guiding source selection by identifying performance across a wide range of imaging conditions and purposes. By providing a standardized and quantitative assessment framework, this work enables more informed selection and optimization of X-ray sources—both for users and manufacturers—ultimately improving CT imaging performance.

Place, publisher, year, edition, pages
2025. , p. 65
Series
UPTEC F, ISSN 1401-5757 ; 25047
Keywords [en]
computed tomography, CT, x-ray, x-ray source, performance, x-ray imaging, image quality, resolution, modulation transfer function, MTF, point spread function, PSF, noise power spectrum, NPS, signal to noise ratio, SNR, Rose criterion, simulation, radiography, detail detection limit, cylinder, circular edge, brightness, noise, image quality metric, edge spread function, line spread function
National Category
Radiology and Medical Imaging
Identifiers
URN: urn:nbn:se:uu:diva-564766OAI: oai:DiVA.org:uu-564766DiVA, id: diva2:1988351
External cooperation
Excillum AB
Educational program
Master Programme in Engineering Physics
Supervisors
Examiners
Available from: 2025-08-25 Created: 2025-08-11 Last updated: 2025-08-25Bibliographically approved

Open Access in DiVA

fulltext(12929 kB)257 downloads
File information
File name FULLTEXT01.pdfFile size 12929 kBChecksum SHA-512
4b061be2cd352447a292dc69035c3f4d75fba7ba18bedf8ad1ba3da9a4ed03f092ed5909fdac9c3939424db84458dcce7503320ae5591b7e44e240c52471248d
Type fulltextMimetype application/pdf

By organisation
Department of Physics and Astronomy
Radiology and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
Total: 258 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 271 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf