Digitala Vetenskapliga Arkivet

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Respiratory motion management for proton and photon radiation therapy of small lung tumors
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Immunology, Genetics and Pathology.ORCID iD: 0000-0002-3300-6412
2025 (English)Doctoral thesis, comprehensive summary (Other academic)
Description
Abstract [en]

Lung cancer is globally recognized as the most common cause of cancer related death. The general prognosis is poor but for patients with early stage lung cancer very good local control can be achieved using stereotactic body radiation therapy (SBRT). These treatments are characterized by high doses to well defined targets delivered with high precision at a few treatment occasions. The common way of delivering these treatments is with X-ray photon beams. However, could these treatments be performed with proton therapy instead the theoretical dosimetric advantages of charged particle radiation therapy could be exploited to drastically reduce the dose given to healthy tissues. The very first proton therapies of cancer were given in Uppsala in the 1950s. Since 2015 modern proton therapy is available at the Skandion clinic in Uppsala but to this date no SBRT and no lung cancer patients have yet been treated which is addressed in this thesis.

When treating thoracic tumors the management of respiratory motion is of great importance and various strategies have been developed.

In this project, treatment planning methods for photon SBRT that take the respiratory motion into account were first evaluated and compared. Further, methods for treatment planning and evaluation were developed for proton SBRT. Additional imaging and treatment simulation strategies were used for the evaluation of the investigated treatment planning methods. Both treatments in free-breathing and in voluntary breath-hold were explored using the proposed methods.

The results indicate that robust treatment planning for this patient group can guarantee the desired target coverage for both proton and photon SBRT delivered in either free-breathing or breath-hold.

Further, proton therapy demonstrated a large reduction in dose to all surrounding organs which would further translate into clinical benefits for the patients treated with proton therapy compared with conventional photon radiation therapy.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2025. , p. 60
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, ISSN 1651-6206 ; 2169
Keywords [en]
Radiation therapy, Lung cancer, Proton therapy
National Category
Cancer and Oncology
Identifiers
URN: urn:nbn:se:uu:diva-564488ISBN: 978-91-513-2545-3 (print)OAI: oai:DiVA.org:uu-564488DiVA, id: diva2:1987068
Public defence
2025-09-19, Rudbecksalen, Dag Hammarskjölds Väg 20, Uppsala, 08:30 (English)
Opponent
Supervisors
Available from: 2025-08-28 Created: 2025-08-05 Last updated: 2025-08-28
List of papers
1. Dosimetric robustness of lung tumor photon radiotherapy evaluated from multiple event CT imaging
Open this publication in new window or tab >>Dosimetric robustness of lung tumor photon radiotherapy evaluated from multiple event CT imaging
Show others...
2022 (English)In: Physica medica (Testo stampato), ISSN 1120-1797, E-ISSN 1724-191X, Vol. 103, p. 1-10Article in journal (Refereed) Published
Abstract [en]

Purpose: Intrafractional respiratory motion is a concern for lung tumor radiotherapy but full evaluation of its impact is hampered by the lack of images representing the true motion. This study presents a novel evaluation using free-breathing images acquired over realistic treatment times to study the dosimetric impact of respiratory motion in photon radiotherapy.

Methods: Cine-CT images of 14 patients with lung cancer acquired during eight minutes of free-breathing at three occasions were used to simulate dose tracking of four different planning methods. These methods aimed to deliver 54 Gy in three fractions to D50% of the target and were denoted as robust 4D (RB4), homogeneous fluence to the ITV (FLU) and an isodose prescription to the ITV with a high central dose (ISD), concurrently renormalized (IRN). Differences in dose coverage probability and homogeneity between the methods were quantified. Correlations between underdosage and attributes regarding the tumor and its motion were investigated.

Results: Despite tumor motion amplitudes being larger than in the 4DCT all but FLU achieved the intended CTV D50% for the cohort average. For all methods but IRN at least 93% of the patients would have received 95% of the intended dose. No differences in D50% were found between RB4 and ISD nor IRN. However, RB4 led to better homogeneity.

Conclusions: Tumor motion in free-breathing not covered by the 4DCT had a small impact on dose. The RB4 is recommended for planning of free-breathing treatments. No factor was found that consistently correlated dose degradation with patient or motion attributes.

Place, publisher, year, edition, pages
Elsevier, 2022
National Category
Cancer and Oncology
Identifiers
urn:nbn:se:uu:diva-485903 (URN)10.1016/j.ejmp.2022.09.007 (DOI)000882511000001 ()36182764 (PubMedID)
Funder
Swedish Cancer Society, CAN 2017-616Uppsala University
Available from: 2022-09-28 Created: 2022-09-28 Last updated: 2025-08-05Bibliographically approved
2. Impact of setup and geometric uncertainties on the robustness of free-breathing photon radiotherapy of small lung tumors
Open this publication in new window or tab >>Impact of setup and geometric uncertainties on the robustness of free-breathing photon radiotherapy of small lung tumors
Show others...
2024 (English)In: Physica medica (Testo stampato), ISSN 1120-1797, E-ISSN 1724-191X, Vol. 123, article id 103396Article in journal (Refereed) Published
Abstract [en]

Purpose:

Respiratory motion and patient setup error both contribute to the dosimetric uncertainty in radiotherapy of lung tumors. Managing these uncertainties for free-breathing treatments is usually done by margin-based approaches or robust optimization. However, breathing motion can be irregular and concerns have been raised for the robustness of the treatment plans. We have previously reported the dosimetric effects of the respiratory motion, without setup uncertainties, in lung tumor photon radiotherapy using free-breathing images. In this study, we include setup uncertainty.

Methods:

Tumor positions from cine-CT images acquired in free-breathing were combined with per-fraction patient shifts to simulate treatment scenarios. A total of 14 patients with 300 tumor positions were used to evaluate treatment plans based on 4DCT. Four planning methods aiming at delivering 54 Gy as median tumor dose in three fractions were compared. The planning methods were denoted robust 4D (RB4), isodose to the PTV with a central higher dose (ISD), the ISD method normalized to the intended median tumor dose (IRN) and homogeneous fluence to the PTV (FLU).

Results:

For all planning methods 95% of the intended dose was achieved with at least 90% probability with RB4 and FLU having equal CTV values D50% at this probability. FLU gave the most consistent results in terms of CTV D50% spread and dose homogeneity.

Conclusions:

Despite the simulated patient shifts and tumor motions being larger than observed in the 4DCTs the dosimetric impact was suggested to be small. RB4 or FLU are recommended for the planning of free-breathing treatments.

Place, publisher, year, edition, pages
Elsevier, 2024
Keywords
Lung cancer, SBRT, Robust evaluation, Setup error, Respiratory motion
National Category
Cancer and Oncology
Identifiers
urn:nbn:se:uu:diva-533945 (URN)10.1016/j.ejmp.2024.103396 (DOI)001266636000001 ()38943799 (PubMedID)
Funder
Uppsala UniversitySwedish Cancer Society, CAN 2017-616
Available from: 2024-06-29 Created: 2024-06-29 Last updated: 2025-08-05Bibliographically approved
3. Consistent robust treatment planning and displacement vector field editing for the probabilistic evaluation of radiotherapy of small lung tumors
Open this publication in new window or tab >>Consistent robust treatment planning and displacement vector field editing for the probabilistic evaluation of radiotherapy of small lung tumors
(English)Manuscript (preprint) (Other academic)
National Category
Cancer and Oncology
Research subject
Medical Science
Identifiers
urn:nbn:se:uu:diva-564485 (URN)
Available from: 2025-08-05 Created: 2025-08-05 Last updated: 2025-08-09
4. Comparison of proton and photon lung SBRT in free-breathing
Open this publication in new window or tab >>Comparison of proton and photon lung SBRT in free-breathing
(English)Manuscript (preprint) (Other academic)
National Category
Cancer and Oncology
Research subject
Medical Science; Medical Science
Identifiers
urn:nbn:se:uu:diva-564486 (URN)
Available from: 2025-08-05 Created: 2025-08-05 Last updated: 2025-08-05
5. Effects of breath-hold reproducibility uncertainty on proton and photon lung cancer radiotherapy
Open this publication in new window or tab >>Effects of breath-hold reproducibility uncertainty on proton and photon lung cancer radiotherapy
(English)Manuscript (preprint) (Other academic)
National Category
Cancer and Oncology
Research subject
Medical Science
Identifiers
urn:nbn:se:uu:diva-564487 (URN)
Available from: 2025-08-05 Created: 2025-08-05 Last updated: 2025-08-09

Open Access in DiVA

UUThesis_Olovsson,N-2025(1623 kB)292 downloads
File information
File name FULLTEXT01.pdfFile size 1623 kBChecksum SHA-512
4ef080c2be128ad13dc62378bd3899de4c469fec8054d4adc7b501c7f0607d87f50271f66477a789addeb8a92a2ed0c40599ffe71d6fe8a94ad7f43a9853e8bd
Type fulltextMimetype application/pdf

Other links

Online defence

Search in DiVA

By author/editor
Olovsson, Nils
By organisation
Department of Immunology, Genetics and Pathology
Cancer and Oncology

Search outside of DiVA

GoogleGoogle Scholar
Total: 295 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 2107 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf