Digitala Vetenskapliga Arkivet

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Feasibility Study on Using Electrochemical Impedance Spectroscopy (EIS) for Estimating the States of Li-Ion Batteries
KTH, School of Engineering Sciences in Chemistry, Biotechnology and Health (CBH), Chemical Engineering.
2025 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesisAlternative title
Genomförbarhetsstudie om användning av elektrokemisk impedansspektroskopi (EIS) för att uppskatta tillståndet för Li-jonbatterier (Swedish)
Abstract [sv]

Det ökande behovet av hållbara transporter ställer krav på säkra batteriteknologier, där litiumjonbatterier (LiB) spelar en central roll i elektrifieringen av transportsektorn. Noggrann mätning av interna batteriparametrar, såsom cellens inre temperatur och laddningstillstånd (State of Charge, SOC), är avgörande för att säkerställa optimal prestanda, säkerhet och livslängd. Traditionellt sker temperaturmätning via sensorer monterade på cellens yta, vilket innebär att endast cellens yttemperatur registreras. Detta utgör en begränsning eftersom termiska händelser, såsom termisk rusning, uppstår inuti cellen, vilket medför en fördröjning mellan den interna temperaturökningen och att den registreras av sensorn. Elektrokemisk impedansspektroskopi (Electrochemical Impedance Spectroscopy, EIS) erbjuder däremot en icke-invasiv metod som är känslig för interna elektrokemiska och termiska förhållanden, vilket möjliggör en mer representativ och snabbare övervakning av cellens inre tillstånd.

Denna studie undersöker impedansbeteendet hos kommersiella prismatiska battericeller under ett brett spektrum av kontrollerade testförhållanden. Två experimentserier genomfördes: en för temperaturuppskattning och en för SOC-uppskattning. I temperaturserien utfördes EIS-mätningar vid 18 distinkta temperaturer (−25 °C till +55 °C) vid tre SOC-nivåer (5 , 50 och 95 %). I SOC-serien utfördes mätningar vid 21 SOC-nivåer, från 0 % till 100 %, vid åtta olika temperaturer. Samtliga mätningar genomfördes med en kalibrerad flerkanalig testuppställning, och datakorrigeringsmetoder tillämpades för att kompensera för hårdvarurelaterade impedansavvikelser.

Tre metoder för temperaturuppskattning utvärderades, baserade på olika impedanskomponenter: den reella delen (𝑍𝑟𝑒), den negativa imaginära delen (−𝑍𝑖𝑚) samt den negativa fasvinkeln (−𝜙). Varje metod modellerades med en Arrhenius-liknande eller linjär funktion, och modellerna anpassades till mätdata via icke-linjär regressionsanalys. Noggrannhet och robusthet gentemot variationer i SOC kvantifierades. Bland metoderna uppvisade −𝑍𝑖𝑚 vid en enskild medel-hög frekvens (500 Hz) den bästa prestandan, med en noggrannhet på ±5,1℃ och en påverkan av laddningstillståndet (SOC) på ±4,6℃. Validering mot oberoende datamängder, inklusive åldrade celler och körcykeltest, visar att modellen har potential att även inkludera state of health (SOH), även om detta inte implementerats inom ramen för denna studie.

För uppskattning av SOC användes ekvivalenta kretsmodeller (Equivalent Circuit Models, ECM), anpassade till impedansspektra framtagna i mjukvaran RelaxIS. Impedansdata för alla SOC-nivåer vid varje temperatur anpassades till en gemensam krets för att möjliggöra extraktion av kretsparametrar. Inga tydliga trender I dessa parametrar relaterade till SOC kunde dock identifieras. Detta förklaras med avvikelser som uppstod vid sammanslagning av korrigerad högfrekvensdata och icke-korrigerad lågfrekvensdata, samt brus från mätkanalerna.

Sammantaget visar resultaten att temperaturuppskattning med EIS har potential att utvecklas vidare, inklusive integreringen av ytterligare parametrar såsom SOH, för att möjliggöra tillämpning i ett bredare spektrum av driftförhållanden. Däremot präglas SOC-uppskattningen av flera begränsningar som måste hanteras innan tillförlitliga slutsatser kan dras om metodens användbarhet.

Abstract [en]

The growing demand for sustainable transportation necessitates robust and safe battery technologies, with lithium-ion batteries (LiBs) playing a central role in electrifying the vehicle fleet. Accurate monitoring of internal battery parameters such as internal temperature and state of charge (SOC) is essential for ensuring optimal performance, safety, and longevity. Conventionally, temperature measurements rely on surface-mounted sensors, which inherently capture only the external temperature of the cell. This poses a critical limitation, as thermal events such as thermal runaway originate within the cell core, leading to a time delay between internal temperature rise and external detection. In contrast, Electrochemical Impedance Spectroscopy (EIS) offers a non-invasive, sensorless approach that is inherently sensitive to internal electrochemical and thermal conditions, thereby enabling more timely and representative monitoring of the cell’s internal state.

The work focuses on investigating the impedance characteristics of commercial prismatic battery cells under a wide range of controlled conditions. Two experimental series were conducted: one for temperature estimation and another for SOC estimation. In the temperature test, EIS measurements were performed at 18 discrete temperatures (−25 °C to +55 °C) at three SOC levels (5 %, 50 %, and 95 %). In the SOC test, EIS measurements were performed at 21 SOC levels, spanning 0–100 %, across eight temperatures. All measurements were conducted using a calibrated multi-channel battery test setup, and data correction methods were applied to account for hardware-induced impedance offsets.

Three temperature estimation methods were evaluated, based on different impedance features: the real part (𝑍𝑟𝑒), the negative imaginary part (−𝑍𝑖𝑚), and the negative phase angle (−𝜙), each modeled using an Arrhenius-type or linear expression. The models were fitted to measurement data using nonlinear regression, and their accuracy and robustness to SOC variations were quantified. Among these, the method based on −𝑍𝑖𝑚 at a single mid-frequency (500 Hz) showed the best performance, achieving an estimation accuracy of ±5.1℃ and exhibiting a SOC influence of ±4.6℃. Through validation on independently measured datasets, including aged cells and drive cycle conditions, it could be concluded that the model can be extended to also account for state of health (SOH) changes, though this lies outside the present study’s implementation.

For SOC estimation, Equivalent Circuit Models (ECMs) were fitted to impedance spectra obtained from RelaxIS software. Impedance data from all SOC levels at each temperature were collectively fitted to the same circuit, allowing extraction of circuit parameters. No consistent trends in circuit parameters with respect to SOC were observed. This absence of clear correlations is attributed to discrepancies arising from the merging of corrected high-frequency data with uncorrected low-frequency data, as well as measurement noise introduced by test channel variability.

Overall, the results demonstrate that temperature estimation using EIS holds promise for further development, including the incorporation of additional parameters such as SOH, to enable applicability under a broader range of operating conditions. In contrast, the SOC estimation approach is subject to several limitations that must be carefully addressed and resolved before reliable conclusions can be drawn regarding its feasibility.

Place, publisher, year, edition, pages
2025.
Series
TRITA-CBH-GRU ; 2025:194
Keywords [en]
Electrochemical Impedance Spectroscopy, Lithium-ion battery, State of Charge, Temperature Estimation, Sensorless Monitoring
Keywords [sv]
Elektrokemisk impedansspektroskopi, Litiumjonbatteri, Laddningstillstånd, Temperaturuppskattning, Sensorlös mätning
National Category
Inorganic Chemistry
Identifiers
URN: urn:nbn:se:kth:diva-367713OAI: oai:DiVA.org:kth-367713DiVA, id: diva2:1985924
External cooperation
Scania CV AB
Subject / course
Chemical Engineering
Educational program
Degree of Master - Chemical Engineering for Energy and Environment
Examiners
Available from: 2025-07-29 Created: 2025-07-29

Open Access in DiVA

fulltext(4675 kB)340 downloads
File information
File name FULLTEXT01.pdfFile size 4675 kBChecksum SHA-512
7221083a9e7d8b0d238c3819af3619634ca47e4dfc750c06d7ab211ac0bebae3718ad9317bf91cc7c709f3275f41dfa12b840940cc4b8da0a47f9c4a3a5a40bd
Type fulltextMimetype application/pdf

By organisation
Chemical Engineering
Inorganic Chemistry

Search outside of DiVA

GoogleGoogle Scholar
Total: 341 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1209 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf