Development of a GC-MS Based Method for Measuring Organic Degradation Compounds in Lithium-Ion Battery Electrolyte
2025 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE credits
Student thesisAlternative title
Utveckling av en GC-MS-baserad metod för att mäta organiska nedbrytningsprodukter i litium-jon batteriers elektrolyt (Swedish)
Abstract [sv]
Kvantifiering av organiska nedbrytningsprodukter i litium-jon batteriers (LIB) elektrolyter är avgörande för att förstå batteriers åldringsmekanismer och förbättra deras långsiktiga prestanda. Denna studie, som genomfördes i samarbete med Scania CV AB, fokuserar på utvecklingen av en GC-MS-baserad (Gas Kromatografi–Masspektrometri) analysmetod som möjliggör detektering av organiska nedbrytningsprodukter utan att skada instrumentet genom elektrolytsalter såsom LiPF6.
För att uppnå detta utvärderades två provberedningsmetoder, vätske–vätskeextraktion (LLE) och headspace-analys (HS), med avseende på saltborttagning från elektrolyten, extraktionseffektivitet och signal–brus-förhållande, vilka alla är viktiga aspekter för tillförlitlig kvantifiering. Inom LLE-metoden testades tre extraktionslösningsmedel: diklormetan (DCM), cyklohexan och metyltertiärbutyleter (MTBE). För DCM utvärderades två varianter: en med tillsatt vatten och en utan, medan vatten tillsattes i övriga fall för att kunna separera salt från elektrolyten före GC-MS-analys. Parallellt undersöktes headspace-analys vid olika inkubationstemperaturer för att utvärdera de organiska nedbrytningsföreningarnas termiska beteende och flyktighet.
Alla metoder lyckades detektera nedbrytningsprodukterna DMDOHC, EMDOHC, DEDOHC och DEC. MTBE lyckades dock inte separera salterna, och DCM utan tillsatt vatten resulterade i kromatogram med lågt signal–brus-förhållande. Däremot visade LLE med DCM och vatten mycket god prestanda, med låg bakgrundsnivå och väl separerade toppar lämpliga för kvantifiering. Även headspace-analys uppvisade god känslighet och rena kromatogram, samtidigt som inga extraktionslösningsmedel behövdes, vilket förenklade provberedningen.
Dessa metoder kunde även särskilja koncentrationsvariationer mellan celler i början (BOL) och slutet (EOL) av livscykeln, vilket bekräftar deras lämplighet för kvantitativ analys av elektrolytnedbrytning. Studien presenterar ett reproducerbart och instrumentvänligt protokoll för LIB-elektrolytanalyser, med lovande tillämpningar inom både forskning och industri.
Abstract [en]
Accurate quantification of organic degradation compounds in lithium-ion battery (LIB) electrolytes is essential for understanding battery aging mechanisms and improving long-term performance. This study, conducted in collaboration with Scania CV AB, focuses on the development of a Gas Chromatography-Mass Spectrometry (GC-MS) based analytical method capable of detecting organic degradation products while avoiding damage from electrolyte salts such as LiPF6.
To achieve this, two sample preparation techniques, liquid–liquid extraction (LLE) and headspace (HS) sampling, were systematically evaluated with respect to salt removal efficiency, extraction performance, and signal-to-noise ratio, all of which are critical for reliable quantification. Within the LLE approach, three extraction solvents were tested: dichloromethane (DCM), cyclohexane, and methyl tert-butyl ether (MTBE). For DCM, two variants were assessed: one with added water and one without, while water was included in all other cases to promote salt separation prior to GC-MS analysis. In parallel, headspace sampling was explored under varying incubation temperatures to evaluate the thermal behaviour and volatility of the degradation compounds.
All methods successfully detected degradation products, including DMDOHC, EMDOHC, DEDOHC, and DEC. However, MTBE failed to effectively separate the salts, and DCM without water produced chromatograms with poor signal-to-noise ratio. In contrast, LLE using DCM and water proved highly effective, yielding low background noise and well-separated peaks suitable for quantification. Headspace sampling also demonstrated good sensitivity and clean chromatograms, while eliminating the need for extraction solvents.
These methods enabled detection of concentration variations between beginning-of-life and end-of-life cells, confirming their suitability for quantitative analysis of electrolyte degradation. This work presents a reproducible and instrument-safe protocol for LIB electrolyte analysis, with promising applications in both research and industrial settings.
Place, publisher, year, edition, pages
2025.
Series
TRITA-CBH-GRU ; 2025:249
Keywords [en]
Battery aging, LIB electrolyte, GC-MS, liquid-liquid extraction, headspace analysis
Keywords [sv]
Batteriers åldrande, litium-jon batteri elektrolyt, GC-MS, vätske-vätske extraktion, headspace-analys
National Category
Analytical Chemistry
Identifiers
URN: urn:nbn:se:kth:diva-367712OAI: oai:DiVA.org:kth-367712DiVA, id: diva2:1985923