The estimation of neuron numbers in defined brain nuclei is important for investigations into preclinical rodent models of neuro-degenerative disorders as well as therapeutical interventions. Traditional manual analysis of immunohistochemical (IHC) images is not only labor-intensive but also prone to subjectivity, leading to reduced reproducibility. While the stereological quantification using the optical fractionator principle remains the gold standard for unbiased estimation, its application demands specialized equipment, proprietary software, and significant time investment. Recent advancements in computer vision and machine learning have paved the way for automated solutions to these challenges.After training several detector networks we evaluated the individual performance against manual quantification (Ground Truth), the best performing network (YOLOv11m) was then compared against manual quantification and quantification obtained from proprietary software (AIforia®). The algorithm demonstrates superior efficiency in both training and inference times, alongside high accuracy in cell detection. The weights and program are freely available on our GitLab page, including a step-by-step user guide for application and further training. Our proposed network therefore provides a fast and highly reproducible evaluation of dopaminergic cell numbers in the rat Substantia Nigra with minimal programming knowledge.