Digitala Vetenskapliga Arkivet

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Protokollutveckling förprovförberedelse avvassleprotein koncentrat införflödescytometrianalys
Linnaeus University, Faculty of Health and Life Sciences, Department of Chemistry and Biomedical Sciences.
2025 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Vassleprotein koncentrat (WPC) är en proteinrik biprodukt från ostproduktion somvanligtvis analyseras mikrobiologiskt med odlingsbaserade metoder. Dessa metoderär dock tidskrävande och orsakar ekonomiska förluster vid fördröjda analysresultat.Syftet med denna studie var att undersöka om flödescytometri kan användas som ettsnabbare alternativ för att analysera bakterieinnehåll i WPC. För att möjliggörasådan analys utvecklades en provberedningsmetod som syftar till att minska provetsviskositet och avlägsna störande komponenter utan att påverka bakteriernasintegritet. Prover av WPC förbehandlades med enzymet Proteinase K i olikakoncentrationer och inkubationstider. Dessutom testades pH-justering ochproteinutfällning för att optimera separationen mellan proteiner och bakterier.Proverna analyserades med både traditionell odling och flödescytometri, där levandeoch döda celler färgades med SYTO 9 respektive propidiumjodid (PI). Resultatenvisade att Proteinase K snabbt reducerade proteinhalten i WPC, men samtidigtkunde främja bakterietillväxt vid längre inkubationstider. Odlingarna visade attbakterier huvudsakligen återfanns i pelleten och den första supernatanten, samt attbehandling med enzym eller pH-justering påverkade tillväxtmönstret. Streptococcusthermophilus var en av de vanligast förekommande bakterierna i proverna.Flödescytometri visade begränsad förmåga att skilja levande från döda celler,särskilt i kontroller där hög bakgrund och låg cellkoncentration påverkademätningarnas noggrannhet. En oväntat stor andel levande celler detekterades även idöda kontroller, vilket tyder på att färgningen kan störas av WPC:s komplexasammansättning. Sammanfattningsvis visade studien att en effektiv provberedningär avgörande inför flödescytometrisk analys. Däremot behöver bådefärgningsprotokoll och flödescytometri anpassas bättre till WPC. För framtidastudier rekommenderas optimering av färgningsprotokoll samt utvärdering avalternativa fluoroforer och enzymatiska förbehandlingar.

Abstract [en]

Whey protein concentrate (WPC) is a protein-rich byproduct of cheese productionthat is commonly analyzed microbiologically using culture-based methods.However, these methods are time-consuming and may lead to economic losses dueto delayed analysis results. The aim of this study was to investigate whether flowcytometry could serve as a faster alternative for analyzing bacterial content in WPC.To enable such analysis, a sample preparation method was developed to reduce theviscosity and remove interfering components without compromising bacterialintegrity. WPC samples were pretreated with the enzyme Proteinase K at varyingconcentrations and incubation times. Additionally, pH adjustment and proteinprecipitation were tested to optimize the separation of proteins and bacteria. Thesamples were analyzed using both traditional culturing and flowcytometry, wherelive and dead cells were stained with SYTO 9 and propidium iodide (PI),respectively. The results showed that Proteinase K rapidly reduced the proteincontent in WPC but could also promote bacterial growth at longer incubation times.Culturing revealed that bacteria were primarily found in the pellet and the firstsupernatant, and that enzymatic treatment or pH adjustment affected the growthpattern. Streptococcus thermophilus was identified as one of the most frequentlyoccurring bacteria in the samples. Flowcytometry showed limited ability todistinguish live from dead cells, particularly in controls where high background andlow cell concentrations affected measurement accuracy. An unexpectedly highproportion of live cells was also detected in dead controls, suggesting that thestaining process may be disrupted by the complex composition of WPC. Inconclusion, the study demonstrated that effective sample preparation is crucial forflow cytometric analysis. However, staining protocols and flow cytometry itselfneed to be better adapted to WPC. Future studies are recommended to optimizestaining procedures and evaluate alternative fluorophores and enzymaticpretreatments.

Place, publisher, year, edition, pages
2025. , p. 28
Keywords [en]
Whey protein concentrate, Flowcytometry, Proteinase K, Streptococcus thermophilus
Keywords [sv]
Vassleprotein koncentrat, Flödescytometri, Proteinase K, Streptococcus thermophilus
National Category
Microbiology Other Natural Sciences
Identifiers
URN: urn:nbn:se:lnu:diva-140825OAI: oai:DiVA.org:lnu-140825DiVA, id: diva2:1984595
External cooperation
ARLA Foods Kalmar
Educational program
Biomedical Laboratory Science Programme, 180 credits
Supervisors
Examiners
Available from: 2025-07-18 Created: 2025-07-16 Last updated: 2025-07-18Bibliographically approved

Open Access in DiVA

fulltext(1185 kB)158 downloads
File information
File name FULLTEXT01.pdfFile size 1185 kBChecksum SHA-512
3ffaaf7010f3ba7960ad7874b84bcfb59ad6a2a813dd39a8edaeec5318475751f07d0fea9175277a61d38952ced194ff10b835ef67a185cc2d3ef38b35bfb937
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Alfarraj, Sara
By organisation
Department of Chemistry and Biomedical Sciences
MicrobiologyOther Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 161 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 437 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf