Implementering av nattkyla på VHC hus 5: En undersökning om nattkylans effekter på energibehov, effektbehov och inomhusklimat
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Civil and Industrial Engineering, Civil Engineering and Built Environment.
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Civil and Industrial Engineering, Civil Engineering and Built Environment.
2025 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Implementation of night cooling in VHC building 5 : A study on the effects of night cooling on energy demand, power demand and indoor climate (English)
Abstract [en]

The ongoing climate change is increasing the demand for more energy-efficient buildings with lower emissions. Currently, buildings are responsible for around 40 % of total energy use in Sweden, with a significant portion of that energy consumed by heating and cooling systems. Reducing the cooling demand during the summer is therefore an important step toward improving energy efficiency. One potential method for lowering cooling demand is night cooling. This technique uses the cooler outdoor air available at night by allowing the building's ventilation system to remain active overnight. In collaboration with Akademiska Hus, this study aims to simulate and evaluate the impact of night cooling on cooling demand, total energy consumption, and peak loads for Building 5 of the VHC complex. The thesis involves a literature review, data collection, site visits, and detailed simulations of the building. The initial simulations were conducted without night cooling. A second set of simulations was then performed after integrating a night cooling system into the model. By comparing the results from both scenarios, the study assessed the effect of night cooling on energy performance and system efficiency. The results showed that night cooling reduces the building's cooling demand by 17 %. However, energy use, fan power, and fan power demand in the building increased because of the fans being turned on during the night. The cooling power demand was reduced by 19 %, which could lead to lower costs by reducing the variable power charge. The implementation of night cooling also improved the indoor climate in the morning by lowering the average temperature.  The conclusion is that night cooling has a positive impact on the building's cooling demand. However, it increases energy use, fan power, and fan power output. Despite this, night cooling can be recommended due to its positive effect on the indoor climate in the morning as well as the reduced cooling load.

Place, publisher, year, edition, pages
2025. , p. 36
Keywords [sv]
byggteknik, energieffektivisering, effektbesparing, energibesparing, IDA ICE, kylbehov, nattkyla
National Category
Construction Management Building Technologies
Identifiers
URN: urn:nbn:se:uu:diva-563654ISRN: UTH-INGUTB-EX-B-2025/027-SEOAI: oai:DiVA.org:uu-563654DiVA, id: diva2:1983566
External cooperation
Akademiska hus
Educational program
Bachelor Programme in Construction Engineering
Supervisors
Examiners
Available from: 2025-08-05 Created: 2025-07-11 Last updated: 2025-08-05Bibliographically approved

Open Access in DiVA

Implementering av nattkyla på VHC hus 5(18822 kB)180 downloads
File information
File name FULLTEXT01.pdfFile size 18822 kBChecksum SHA-512
ab0e3f570ff60d15d646042421f2bce4f57d88c3341aecd11b5c3d941973af0a8e6a100383d87a9002531a6ecddee522c9c0c10637ec8c4ceab6ffe1a7dc3ece
Type fulltextMimetype application/pdf

By organisation
Civil Engineering and Built Environment
Construction ManagementBuilding Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 183 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 263 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf