Effects of Physiological Loading from Patient-Derived Activities of Daily Living on the Wear of Metal-on-Polymer Total Hip Replacements
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Machine Elements.ORCID iD: 0009-0006-2194-5021
School of Engineering, University of Birmingham, Birmingham B15 2TT, UK.
Institute for Biomechanics, ETH Zürich, 8092 Zürich, Switzerland.
NIHR Leeds Biomedical Research Centre, Leeds, LS7 4SA, UK; Institute for Rheumatic and Musculoskeletal Medicine, University of Leeds, Leeds LS7 4SA, UK.
Show others and affiliations
2025 (English)In: Bioengineering, E-ISSN 2306-5354, Vol. 12, no 6, article id 663Article in journal (Refereed) Published
Abstract [en]

The current pre-clinical testing standards for total hip replacements (THRs), ISO standards, use simplified loading waveforms that do not fully replicate real-world biomechanics. These standards provide a benchmark of data that may not accurately predict in vivo wear, necessitating the evaluation of physiologically relevant loading conditions. Previous studies have incorporated activities of daily living (ADLs) such as walking, jogging and stair negotiation into wear simulations. However, these studies primarily used simplified adaptations that increased axial forces and applied accelerated sinusoidal waveforms, rather than fully replicating the complex kinematics experienced by THR patients. To address this gap, this study applied patient-derived ADL profiles—jogging and stair negotiation—using a three-station hip simulator, obtained through 3D motion analysis of total hip arthroplasty patients, processed via a musculoskeletal multibody modelling approach to derive realistic hip contact forces (HCFs). The results indicate that jogging significantly increased wear rates compared to the ISO walking gait waveform, with wear increasing from 15.24 ± 0.55 to 28.68 ± 0.87 mm3/Mc. Additionally, wear was highly sensitive to changes in lubricant protein concentration, with an increase from 17 g/L to 30 g/L reducing wear by over 60%. Contrary to predictive models, stair descent resulted in higher volumetric wear (8.62 ± 0.43 mm3/0.5 Mc) compared to stair ascent (4.15 ± 0.31 mm3/0.5 Mc), despite both profiles having similar peak torques. These findings underscore the limitations of current ISO standards in replicating physiologically relevant wear patterns. The application of patient-specific loading profiles highlights the need to integrate ADLs into pre-clinical testing protocols, ensuring a more accurate assessment of implant performance and longevity.

Place, publisher, year, edition, pages
Multidisciplinary Digital Publishing Institute (MDPI) , 2025. Vol. 12, no 6, article id 663
Keywords [en]
total hip replacement, activities of daily living, physiological loading, joint simulator testing
National Category
Mechanical Engineering Materials Engineering
Research subject
Machine Elements
Identifiers
URN: urn:nbn:se:ltu:diva-114024DOI: 10.3390/bioengineering12060663ISI: 001516229200001Scopus ID: 2-s2.0-105009148958OAI: oai:DiVA.org:ltu-114024DiVA, id: diva2:1982723
Funder
EU, Horizon 2020, 956004
Note

Validerad;2025;Nivå 2;2025-07-08 (u2);

Full text: CC BY license;

Available from: 2025-07-08 Created: 2025-07-08 Last updated: 2026-10-12Bibliographically approved
In thesis
1. Preclinical Evaluation of Polymer-Based Bearing Systems for Total Hip Replacemen: Physiologically Relevant Loading, Wear Particle Characterisation, and Additively Manufactured PEEK Materials
Open this publication in new window or tab >>Preclinical Evaluation of Polymer-Based Bearing Systems for Total Hip Replacemen: Physiologically Relevant Loading, Wear Particle Characterisation, and Additively Manufactured PEEK Materials
2026 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Background:Total hip replacement is one of the most successful orthopaedic interventions; however, wearremains a key factor influencing long-term implant performance and survivorship. Additivelymanufactured (AM) PEEK materials have emerged as potential candidates for orthopaedicbearing applications, although their tribological and biological performance under clinically representative conditions remains insufficiently understood.

Aim: The aim of this thesis was to evaluate the tribological and biological performance of AMPEEK materials for orthopaedic bearing applications, focusing on the influence of manufacturing, surface finishing, composite reinforcement, and wear particle isolation and characterisation. In parallel, the thesis investigated the influence of physiologically representative loading profiles on wear behaviour in conventional metal-on-polymer systemsto assess limitations in current preclinical testing approaches.

Methods: This thesis combined a systematic review with experimental evaluation of AM PEEKmaterials and conventional orthopaedic bearing systems. Tribological performance wasassessed using multidirectional pin-on-disc testing under clinically relevant articulationconditions, including evaluation of surface topography, wear behaviour, and wear particlegeneration. A vacuum oven stabilisation approach was developed to improve gravimetric assessment of AM PEEK by reducing the influence of manufacturing-induced porosity onfluid absorption and mass stability.Wear particles were isolated using a phenol-based separation method designed to retain both polyethylene and PEEK particles despite similarities in material and protein density, before characterisation using scanning electron microscopy and in vitro biological assays. Inparallel, physiologically representative loading profiles were applied to conventional metalon-polymer hip systems using full-scale hip simulator testing to investigate their influence on preclinical wear assessment.

Key findings: Surface integrity was identified as a critical determinant of tribological performance in AMPEEK, with manufacturing-induced porosity and surface condition exerting greater influence than surface roughness alone. A vacuum oven stabilisation approach enabled improved gravimetric assessment of AM PEEK by reducing variability associated with fluid uptake and release. A phenol-based isolation method enabled recovery and characterisation of both polyethylene and PEEK wear particles for biological evaluation. AM PEEK demonstrated biological responses comparable to conventional materials, although composite reinforcement did not improve wear or biological performance. Finally, physiologically representative loading increased wear in conventional metal-on-polymer systems relative to standardised conditions, highlighting the importance of clinically representative preclinical evaluation, to prevent underestimation of wear in-situ.

Interpretation: Collectively, the findings indicate that tribological performance of additively manufactured PEEK is governed more strongly by manufacturing- and finish-induced surface integrity thanby surface roughness alone. Physiologically representative loading and multidirection alarticulation substantially influenced wear behaviour, highlighting limitations of simplified preclinical testing approaches and reinforcing the importance of clinically relevant evaluationframeworks. Furthermore, while additively manufactured PEEK demonstrated biological responses comparable to conventional materials, improvements in tribological performance remain important for supporting further biological validation and development of orthopaedic bearing systems.

Conclusions: This thesis demonstrates the importance of clinically relevant tribological evaluation forassessing emerging orthopaedic bearing materials. Physiologically representative loading altered wear behaviour in conventional metal-on-polymer systems, while multidirectional articulation provided greater insight into the tribological performance of additively manufactured PEEK materials.While additively manufactured PEEK demonstrated biological responses comparable toconventional materials, tribological performance remained strongly dependent on manufacturing- and finish-induced surface integrity and was not improved through theintroduction of composite reinforcement. Overall, the findings support continued investigation of additively manufactured PEEK as a candidate orthopaedic bearing material, while highlighting the need for further optimisationof manufacturing processes and more clinically representative evaluation methodologies prior to translation.

Place, publisher, year, edition, pages
Luleå: Luleå University of Technology, 2026
Series
Doctoral thesis / Luleå University of Technology, ISSN 1402-1544
Keywords
Total hip replacement, Orthopaedic tribology, Polyetheretherketone (PEEK), Additive manufacturing, Wear, Wear particles, Multidirectional articulation, Physiological loading, Surface integrity, Biological response
National Category
Bio Materials Composite Science and Engineering Other Mechanical Engineering Manufacturing, Surface and Joining Technology
Research subject
Machine Elements
Identifiers
urn:nbn:se:ltu:diva-120057 (URN)978-91-8142-167-5 (ISBN)978-91-8142-168-2 (ISBN)
Public defence
2026-12-01, E231, Luleå University of Technology, Luleå, 09:00 (English)
Opponent
Supervisors
Available from: 2026-10-08 Created: 2026-10-06 Last updated: 2026-11-03Bibliographically approved

Open Access in DiVA

fulltext(1615 kB)130 downloads
File information
File name FULLTEXT01.pdfFile size 1615 kBChecksum SHA-512
6be106602ab6a35533c259510ff24cfe96c01a83abaae75c375f92566f6e4ac5039f160a63bc9e831070c441f38082896db0a3e5dda42fe12a83b69d473df5c4
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Clegg, Benjamin A.Emami, Nazanin
By organisation
Machine Elements
In the same journal
Bioengineering
Mechanical EngineeringMaterials Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 133 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 758 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf