Digitala Vetenskapliga Arkivet

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Hygrotermisk simulering av en medeltida katedrals tilläggsisolerade kyrkvind: två olika modelleringsmetoder
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.
2025 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Hygrothermal simulation of the insulated attic of a medieval cathedral: a comparison of two modelling approaches (English)
Abstract [sv]

Sverige har en lång historia av kyrkobyggande som sträcker sig tillbaka till medeltiden.Bevarandet av historiska kyrkor har alltid varit en angelägen fråga, men i takt medutvecklingen av modern installationsteknik, där både termisk komfort och energieffektivitetprioriteras, har utmaningarna blivit alltmer komplexa. Byggnadstekniska åtgärder i dessahistoriska byggnader kräver ibland annorlunda metoder och tekniska anpassningar för att påbästa sätt bevara och lämna de gamla konstruktionsdelarna, som har ett stort kulturhistorisktvärde, ostörda. Vinden är en del av kyrkobyggnaden som ofta innehåller många spår av dessäldsta historia och som även kan vara speciellt känslig för ändrat inneklimat orsakat avbyggnadstekniska förändringar.Linköpings domkyrka är Sveriges näst största kyrkobyggnad och har anor från tidig medeltid.Utökad tilläggsisolering av vindsbjälklaget planeras som åtgärd för att förbättra byggnadensenergiprestanda. Syftet med den här studien är att undersöka vilka fukttekniska risker somfinns efter installering av ytterligare isolering på vinden i Linköpings domkyrka. Detta görsmed hjälp av hygrotermisk simulering i programvaran WUFI Plus. Studien syftar även till attutvärdera hur väl WUFI Plus kan hantera modellering och simulering av historiska byggnadersom Linköpings domkyrka, i synnerhet vindsutrymmet i en sådan byggnad.Resultatet av den här studien visar att ytterligare tilläggsisolering av vindsbjälklaget idomkyrkan resulterar i ett kallare klimat och en ökad relativ fuktighet i vindsutrymmet, vilketmedför möjliga risker. Studien visar även att modeller i olika detaljnivå av historiskabyggnader, som Linköpings domkyrka, kan simuleras med acceptabel noggrannhet i WUFI

Abstract [en]

Sweden has a long history of church construction that dates back to the Middle Ages. Thepreservation of historic churches has always been an important concern, but with thedevelopment of modern installation techniques, where both thermal comfort and energyefficiency are prioritized, the challenges have become increasingly complex. Technicalbuilding measures in these historic structures sometimes require different methods andtechnical adaptations in order to preserve and leave undisturbed the old constructionelements, which hold great cultural and historical value. The attic is a part of the churchbuilding that often contains many traces of its earliest history and can be particularly sensitiveto changes in indoor climate caused by technical modifications.Linköping Cathedral is Sweden’s second largest church building and has its origins in theearly Middle Ages. Additional insulation of the attic floor is planned as a measure to improvethe building's energy performance. The purpose of this study is to investigate themoisture-related risks that may arise after installing additional insulation in the attic ofLinköping Cathedral. This is done through hygrothermal simulation using the software WUFI

Place, publisher, year, edition, pages
2025.
Series
TRITA-ABE-MBT ; 25527
Keywords [en]
Linköping cathedral, church attic, insulation, hygrothermal risks, WUFI Plus, hygrothermal simulation, hygrothermal modelling
Keywords [sv]
Linköpings domkyrka, kyrkvind, tilläggsisolering, fukttekniska risker, WUFI Plus, hygrotermisk simulering, hygrotermisk modellering
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-366369OAI: oai:DiVA.org:kth-366369DiVA, id: diva2:1982112
External cooperation
Projektallians AB
Supervisors
Examiners
Available from: 2025-07-07 Created: 2025-07-07

Open Access in DiVA

fulltext(2996 kB)145 downloads
File information
File name FULLTEXT01.pdfFile size 2996 kBChecksum SHA-512
2c06a89d53ba3222a71dd1284ddef4ffc883e3c1b27d82ced13379b56d03adf4ff7a89b32e2858c68c96c32aeb485560aabe6972f03dc1f896f7cb17e67029e9
Type fulltextMimetype application/pdf

By organisation
Building Technology and Design
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 147 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 399 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf