Digitala Vetenskapliga Arkivet

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Modeling Streamer Discharge in Air Using Implicit and Explicit Finite Difference Methods with Flux Correction
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Electrical Engineering, Electricity.
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Electrical Engineering. Hitachi Energy Sweden AB, HVDC R&D Dept, S-72212 Västerås, Sweden..
Univ Sydney, Dept Appl Phys, Sydney, NSW 2006, Australia..
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Electrical Engineering, Electricity.ORCID iD: 0000-0001-6903-3423
2025 (English)In: PLASMA, ISSN 2571-6182, Vol. 8, no 2, article id 21Article in journal (Refereed) Published
Abstract [en]

Implementing a computationally efficient numerical model for a single streamer discharge is essential to understand the complex processes such as lightning initiation and electrical discharges in high voltage systems. In this paper, we present a streamer discharge simulation in air, by solving one-dimensional (1D) drift diffusion reaction (DDR) equations for charged species with the disc approximation for electric field. A recently developed fourth-order space and time-centered implicit finite difference method (FDM) with a flux-corrected transport (FCT) method is applied to solve the DDR equations, followed by a comparative simulation using the well-established explicit FDM with FCT. The results demonstrate good agreement between implicit and explicit FDMs, verifying their reliability for streamer modeling. The total electrons, total charge, streamer position, and hence the streamer bridging time obtained using the FDMs with FCT agree with the same streamer computed in the literature using different numerical methods and dimensions. The electric field is obtained with good accuracy due to the inclusion of image charges representing the electrodes in the disc method. This accuracy can be further improved by introducing more image charges. Both implicit and explicit FDMs effectively capture the key streamer behavior, including the variations in charged particle densities and electric field. However, the implicit FDM is computationally more efficient.

Place, publisher, year, edition, pages
MDPI, 2025. Vol. 8, no 2, article id 21
Keywords [en]
implicit finite difference, explicit finite difference, flux correction, image charges, disc method, streamer discharge
National Category
Computational Mathematics
Identifiers
URN: urn:nbn:se:uu:diva-563353DOI: 10.3390/plasma8020021ISI: 001515012600001OAI: oai:DiVA.org:uu-563353DiVA, id: diva2:1982026
Available from: 2025-07-07 Created: 2025-07-07 Last updated: 2026-09-08Bibliographically approved
In thesis
1. Streamer Discharges in High Voltage and Thundercloud Conditions
Open this publication in new window or tab >>Streamer Discharges in High Voltage and Thundercloud Conditions
2026 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

A comprehensive analysis of streamer discharges is important for understanding the underlying discharge physics in terms of charged particle transport, space charge effects, ionization, attachment, and electric field enhancement, among other parameters. As the initial stage of lightning inside thunderclouds and in high voltage systems, streamer discharges play a significant role as they are the first self-sustained ionized channels that may develop from enhanced electric field regions. Therefore, this thesis aims to conduct a numerical study on streamer discharge dynamics in air under the high voltage and thundercloud conditions.

The streamer models are implemented using the Finite Element Method (FEM) and Finite Difference Method (FDM) in different dimensions, and the findings are compared with the results reported in the literature to understand the numerical aspects of streamer discharge behavior. The humidity effect on streamer discharges is analyzed under high voltage and thundercloud conditions. The local streamer-to-hot-gas discharge transition is studied by applying uniform and prescribed, rapidly increasing background electric fields to represent both the classical streamer discharge development between hydrometeors and the effect of relativistic runaway electron activity within thunderclouds.

The results show that the streamer velocity reduces during the streamer propagation stage as the absolute humidity increases, which is valid for the absolute humidity levels, electrode configurations, applied voltage waveforms, and the numerical methods considered in this thesis. The behavior is attributed to the presence of water molecules in air, which increase the electron attachment, and electron-positive water cluster ion recombination rates, resulting in a low electron density and reduced conductivity in the streamer channel.

In the attempt to understand lightning initiation inside clouds, three different water drop configurations are considered inside a thundercloud. Within the considered simulation time, only a positive streamer is generated from a single water drop, whereas the two and three water drop systems develop both positive and negative streamers. The electrical discharges in a gap are significantly influenced by the presence or absence of simultaneous streamers in other air gaps. The findings obtained from the single drop and two drop configurations indicate that relative humidity levels representative of thundercloud conditions have only a minor influence on both positive and negative streamer dynamics. A collision of both the positive and negative streamers can be observed within two water droplets inside a thundercloud under both imposed electric fields. The maximum gas temperature exceeds 1000 K and a possible mechanism for localized leader inception is identified under a rapidly increasing electric field only.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2026. p. 69
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 2713
Keywords
Gas heating, high voltage, humidity effect, positive streamer discharge, negative streamer discharge, short air gaps, thundercloud
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
urn:nbn:se:uu:diva-597903 (URN)978-91-513-2949-9 (ISBN)
Public defence
2026-10-26, Polhemsalen (10134), Ångströmlaboratoriet, Regementsvägen 10, Uppsala, 13:00 (English)
Opponent
Supervisors
Available from: 2026-10-05 Created: 2026-09-08 Last updated: 2026-10-05

Open Access in DiVA

fulltext(4616 kB)441 downloads
File information
File name FULLTEXT01.pdfFile size 4616 kBChecksum SHA-512
8eac19ec589aae0a4575c33f7e44ea49e9b384a4cc818e9a17480b0251d83e60a7558b088232f2a7a189f74f128157ffb824b94cde5f062ef44c6dd2b60ad347
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Search in DiVA

By author/editor
Jayasinghe, Hasupama P.Arevalo, LilianaCooray, Vernon
By organisation
ElectricityDepartment of Electrical Engineering
Computational Mathematics

Search outside of DiVA

GoogleGoogle Scholar
Total: 442 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 525 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf