Quality Assurance of an Underground Cavern Thermal Energy Storage System: A Case Study in Energy, Power and Loss Calculations for Mälarenergi
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Electrical Engineering, Electricity.
2025 (English)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

A quality assurance of Mälarenergi's energy, power, and loss calculations was conducted in this study. Results from the energy quality assurance showed that the energy storage system holds around 1.26 GWh more energy than Mälarenergi's previous calculations with a temperature distribution based on historical data. Plausibly, if the bottom temperature distribution can reach 45 oC instead of 50 oC, 2.6 GWh more energy than Mälarenergi's calculations is obtained.These cases similarly give an energy capacity of 13.21 GWh and 14.66 GWh respectively, with the assumption that the top maximum temperature distribution can reach 95 oC. Saidtemperature has been reached but with a lesser energy yield.The loss calculations and their validation tested four scenarios, which in the end showed that the bedrock recovers energy to the storage during discharging, with a surprisingly high energy recovery factor of 59%, revealing additional energy content associated with the bedrock, while at the same time evidencing that the storage side power of the heat exchanger is the most accurate power in contrast to the district side. The loss analysis also showed that the gradient first - SL combined method was the best method of the five presented, as it was least sensitive to the heat exchanger power according to the sensitivity analysis and because of its steady losses assumptions. With this method, applied for Scenario 4, a resulting total cumulative energy loss of 33 GWh was found, which was slightly more than the updated predicted loss of 28 GWh. However, the power loss was slightly smaller than predicted during the last 5 months of operation, suggesting that the calculated loss will be smaller than predicted in the near future. This phenomenon is probably due to more cycling than predicted, which hinders more heat from penetrating deep into the bedrock and hence only postpones the initial losses. A power loss model was also created with an ansatz that suggests the losses depend on the energy content and time. The power loss model was applied and compared mainly to the gradient first - SL combined loss method. The result suggested that the model was very accurate over long time spans, as the magnitude of its error was around 0.4%. The loss model did not, however, capture every detail of the power loss, and a Spearman coefficient of around 0.65 was obtained. For further studies, an updated ansatz was suggested that distinguishes the different time periods of charging, discharging, and steady-state periods. Furthermore, a continuous update of the calculations over time is recommended to explore how the energy recovery and energy calculations might be affected, as well as to observe how the losses develop.

Place, publisher, year, edition, pages
2025. , p. 57
Series
UPTEC F, ISSN 1401-5757 ; 25064
Keywords [en]
Thermal Energy Storage, Quality Assurance, Recovery Factor, Heat Losses
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:uu:diva-562715OAI: oai:DiVA.org:uu-562715DiVA, id: diva2:1979571
External cooperation
Mälarenergi AB
Educational program
Master Programme in Engineering Physics
Supervisors
Examiners
Available from: 2025-08-25 Created: 2025-06-30 Last updated: 2025-08-25Bibliographically approved

Open Access in DiVA

fulltext(22079 kB)339 downloads
File information
File name FULLTEXT01.pdfFile size 22079 kBChecksum SHA-512
c424d33db9f5c149f71b4b658b87524613868704b12a99376af252dcae98ea109e16abe0472bc262fdc1af9595c19bae28ada33682bd6f324e56e8f78e78e978
Type fulltextMimetype application/pdf

By organisation
Electricity
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 340 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 431 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf