Battery Electric Multiple Unit trains on Kinnekullebanan: A study regarding charging infrastructure on non-electrified railway lines
2025 (English)Independent thesis Advanced level (professional degree), 20 credits / 30 HE credits
Student thesis
Abstract [en]
This thesis investigates the replacement of diesel trains with battery trains on routes where fully electrifying entire lines is not possible due to protections by law or that it is economically unjustifiable. Having BEMU trains operating at such distances can contribute to sustainable railway traveling. Calculations of energy consumption for market-available Battery Electric Multiple Unit (BEMU) trains and simulations for charging infrastructure at various points along the railway line is conducted, considering charging time, train characteristics and local grid suitability.
Data was collected for BEMU trains to simulate their energy consumption over Kinnekullebanan using Python, accounting for a worst-case scenario with winter conditions in Sweden and nearly end of life battery packs. Additionally, charging infrastructure calculations were performed in Python using designated points along the route for energy requirement analysis. The studied infrastructure methods were to extend the overhead line onto the railway line, construction overhead line island for charging while traveling and stationary charging at the platform.
The results showed that all infrastructure methods were feasible for Kinnekullebanan. Stationary charging at the station in the two larger cities offered the best grid capability and the longest charging times. A single stationary charging station, placed in a rural area mid-route, had weaker grid support and comparable charging times to the two-station setup. Overhead lines in both scenarios resulted in minimal or no charging time at the stations.
BEMU trains with larger installed battery capacities had a lower impact on the local grid, as they retained more energy upon arriving at the station. The proposed charging infrastructure could be used by all trains, although the installed battery capacity varied depending on the location of the charging stations.
In conclusion, battery capacity is crucial for compatibility with potential charging infrastructure locations and methods. The characteristics of BEMU trains must be investigated alongside the charging infrastructure to ensure the trains can reach their end stations successfully.
Place, publisher, year, edition, pages
2025. , p. 67
Series
UPTEC ES, ISSN 1650-8300 ; 25022
Keywords [en]
Battery Electric Multiple Unit, battery train, catenary charging, stationary charging, overhead line island, overhead line extension
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:uu:diva-562682OAI: oai:DiVA.org:uu-562682DiVA, id: diva2:1979375
External cooperation
Sweco Sverige AB
Educational program
Master Programme in Energy Systems Engineering
Supervisors
Examiners
2025-07-042025-06-302025-07-04Bibliographically approved