Battery Electric Multiple Unit trains on Kinnekullebanan: A study regarding charging infrastructure on non-electrified railway lines
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Electrical Engineering, Electricity.
2025 (English)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

This thesis investigates the replacement of diesel trains with battery trains on routes where fully electrifying entire lines is not possible due to protections by law or that it is economically unjustifiable. Having BEMU trains operating at such distances can contribute to sustainable railway traveling. Calculations of energy consumption for market-available Battery Electric Multiple Unit (BEMU) trains and simulations for charging infrastructure at various points along the railway line is conducted, considering charging time, train characteristics and local grid suitability. 

Data was collected for BEMU trains to simulate their energy consumption over Kinnekullebanan using Python, accounting for a worst-case scenario with winter conditions in Sweden and nearly end of life battery packs. Additionally, charging infrastructure calculations were performed in Python using designated points along the route for energy requirement analysis. The studied infrastructure methods were to extend the overhead line onto the railway line, construction overhead line island for charging while traveling and stationary charging at the platform. 

The results showed that all infrastructure methods were feasible for Kinnekullebanan. Stationary charging at the station in the two larger cities offered the best grid capability and the longest charging times. A single stationary charging station, placed in a rural area mid-route, had weaker grid support and comparable charging times to the two-station setup. Overhead lines in both scenarios resulted in minimal or no charging time at the stations.

BEMU trains with larger installed battery capacities had a lower impact on the local grid, as they retained more energy upon arriving at the station. The proposed charging infrastructure could be used by all trains, although the installed battery capacity varied depending on the location of the charging stations.

In conclusion, battery capacity is crucial for compatibility with potential charging infrastructure locations and methods. The characteristics of BEMU trains must be investigated alongside the charging infrastructure to ensure the trains can reach their end stations successfully.

Place, publisher, year, edition, pages
2025. , p. 67
Series
UPTEC ES, ISSN 1650-8300 ; 25022
Keywords [en]
Battery Electric Multiple Unit, battery train, catenary charging, stationary charging, overhead line island, overhead line extension
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:uu:diva-562682OAI: oai:DiVA.org:uu-562682DiVA, id: diva2:1979375
External cooperation
Sweco Sverige AB
Educational program
Master Programme in Energy Systems Engineering
Supervisors
Examiners
Available from: 2025-07-04 Created: 2025-06-30 Last updated: 2025-07-04Bibliographically approved

Open Access in DiVA

fulltext(2318 kB)623 downloads
File information
File name FULLTEXT01.pdfFile size 2318 kBChecksum SHA-512
39ae802132cd342f1b7cda927fc1b040c5d1f44009cf94f710549f0a0e25890987da6bfb1eb7d23bd695a1f24650ec78557212c0ea0d59781e250b3005752e61
Type fulltextMimetype application/pdf

By organisation
Electricity
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 626 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 705 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf