Fault Simulation and Analysis of VSC and LCC HVDC Transmission System in PSCAD
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Electrical Engineering.
2025 (English)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

​This study conducts a systematic comparison of fault behavior in two technologies for HVDC transmission: Line-Commutated Converter (LCC)-based HVDC and Voltage Source Converter (VSC)-based HVDC, utilizing the PSCAD simulation environment. In this thesis, the performance of both types of converter typologies are analyzed under steady-state operation and fault conditions on the second side of the transformer, including line-to-ground, line-to-line, and DC-line fault conditions. Fault conditions with varying fault resistances were simulated, and their associated system responses were analyzed through graphical analysis.

​The simulations were conducted on a 12-pulse LCC-HVDC and a symmetric monopolar VSC-HVDC system. The outcome is that the LCC-based system experiences a sudden decrease in DC voltage during transformer faults and high harmonic distortion levels both in the transformer and DC-line can be observed. In contrast, the VSC-based system-maintained DC-line voltage stability during equivalent fault occurrences. During DC-line faults, both Line-Commutated Converter (LCC) and Voltage Source Converter (VSC) systems exhibit DC voltage drop and extended recovery periods, primarily due to the distinct converter technologies employed in each system. 

The proposed PSCAD based models demonstrate reliable simulation and performance across various fault combinations and fault resistance. This study provides valuable insight into fault behavior in HVDC transmission, highlighting differences in systems performance and the converter technologies. 

Place, publisher, year, edition, pages
2025. , p. 31
Series
ELEKTRO-E ; 25003
Keywords [en]
HVDC transmission system, Line-Commutated Converter (LCC), Voltage Source Converter (VSC), PSCAD, AC-fault, DC-fault, Line-to-Line, Line-to-ground, Fault resistance, IGBT, Thyristors
National Category
Power Systems and Components
Identifiers
URN: urn:nbn:se:uu:diva-562493OAI: oai:DiVA.org:uu-562493DiVA, id: diva2:1978760
External cooperation
Hitachi Energy
Educational program
Master Programme in Electrical Engineering
Supervisors
Examiners
Available from: 2025-06-30 Created: 2025-06-28 Last updated: 2025-06-30Bibliographically approved

Open Access in DiVA

fulltext(2617 kB)3507 downloads
File information
File name FULLTEXT01.pdfFile size 2617 kBChecksum SHA-512
42f6e2f38e2d735635c3be525ac5fcf28728b14a490f3a6bcf1c17e2be9bcc9ecfb4736452bb257c80183d933be209584e01c92f4801850cd011829959af51ea
Type fulltextMimetype application/pdf

By organisation
Department of Electrical Engineering
Power Systems and Components

Search outside of DiVA

GoogleGoogle Scholar
Total: 3509 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 594 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf