Digitala Vetenskapliga Arkivet

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Energieffektivisering av kraftelektroniska system: Potentialen i spillvärmeåtervinning och lokal elproduktion hos STATCOM- och HVDC-stationer
Uppsala University, Disciplinary Domain of Science and Technology, Physics, Department of Physics and Astronomy.
Uppsala University, Disciplinary Domain of Science and Technology, Physics, Department of Physics and Astronomy.
Uppsala University, Disciplinary Domain of Science and Technology, Physics, Department of Physics and Astronomy.
Uppsala University, Disciplinary Domain of Science and Technology, Physics, Department of Physics and Astronomy.
Show others and affiliations
2025 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Syftet med rapporten var att undersöka energieffektivisering av de kraftelektroniska systemen, HVDC (High Voltage Direct Current) och STATCOM (Static Synchronous Compensator). Rapporten undersökte potentiella användningsområden för spillvärme som genereras under stationernas drift, samt om den elkonsumtion som krävs för drift kan produceras inom stationernas yta. Möjliga tillämpningar för spillvärmen som undersöktes var fjärrvärme, elproduktion via organisk Rankine-cykel (ORC), uppvärmning av närliggande växthus och integrering i stationernas befintliga värme- och ventilationssystem (HVAC). Många av de undersökta värmetillämpningarna är tekniskt möjliga att genomföra, givet att stationerna är belägna i närheten av där spillvärmen ska utnyttjas så att konvektionsförluster vid värmetransport inte blir för stora. Gällande egenproduktionen av el undersöktes potentialen av att installera solceller och småskaliga vindkraftverk på stationernas tak. Resultaten indikerar  att varken STATCOM- eller HVDC-stationer kan försörjas helt av lokal elproduktion med solceller och vindkraftverk, då deras egenkonsumtion är högre än den potential som finns för produktion bortsett från några få timmar under dagarna med högst elproduktion. Däremot kan den lokala elproduktionen användas i stationerna i stället för el från nätet, vilket avlastar nätet. Gällande spillvärmeåtervinningen tydde resultaten på att fjärrvärme kunde förstärkas till en viss mån. Växthus i anslutning till STATCOM- och HVDC-stationerna kunde dra relativt stor nytta av spillvärmen. Även organiska Rankine-cykeln kunde producera el, och HVAC-systemen kunde även stödjas.

Abstract [en]

The purpose of the report was to investigate possible energy efficiency improvements of the power electronic systems, HVDC (High Voltage Direct Current) and STATCOM (Static Synchronous Compensator). The report investigated potential areas of use for waste heat generated during the operation of the stations, and if the electricity consumption required for operation can be produced within the stations' premises. The potential applications of waste heat that were explored included district heating, electricity production with organic Rankine cycle (ORC), heating of nearby greenhouses, and integration into the stations' existing heating and air conditioning (HVAC) systems. Many of the investigated waste heat applications are technically feasible, provided that the stations are located close to where the waste heat is to be utilized so that convection losses during heat transport are not too great. Regarding the electricity production, the potential of installing solar panels and smallscale wind turbines on the stations' roofs was investigated. The results indicate that neither the STATCOM nor the HVDC stations can be completely self-sufficient in locally produced electricity, since their usage is greater than the production, except the days with highest electricity production. However, the locally produced electricity can be used by the stations instead of the grid, partly reducing the load on the grid. Regarding heat waste recycling the results indicate that district heating can be partly strengthened. Greenhouses nearby the STATCOM and HVDC stations could be heated with the waste heat. Organic Rankine cycle was another waste heat solution which could produce electricity, and the HVAC systems could be supported as well.

Place, publisher, year, edition, pages
2025. , p. 44
Series
FYSAST ; FYSPROJ1388
Keywords [en]
STATCOM, HVDC, VSC, waste heat, ORC, PV, smallscale windpower
Keywords [sv]
STATCOM, HVDC, VSC, spillvärme, ORC, solceller, småskalig vindkraft
National Category
Electrical Engineering, Electronic Engineering, Information Engineering Power Systems and Components Energy Systems
Identifiers
URN: urn:nbn:se:uu:diva-562407OAI: oai:DiVA.org:uu-562407DiVA, id: diva2:1978471
External cooperation
Hitachi Energy
Educational program
Master Programme in Energy Systems Engineering
Supervisors
Examiners
Available from: 2025-07-01 Created: 2025-06-27 Last updated: 2025-07-01Bibliographically approved

Open Access in DiVA

Kandidatarbete(3636 kB)111 downloads
File information
File name FULLTEXT01.pdfFile size 3636 kBChecksum SHA-512
65b0786d6f3e2887b604a12bb2b18590781361fe1519db109086a92571d4afe0a608a6fad4c714be0d013893aa25b80582a73fc58508909ea5c6635c570772a8
Type fulltextMimetype application/pdf
Delrapport 1(1317 kB)42 downloads
File information
File name FULLTEXT02.pdfFile size 1317 kBChecksum SHA-512
01adbc2408d2c847cc147be6784cf414f3e92135a2d6d0d5bda2afb8dc98b24126fa376350f4f7461f2f57a2c8931d1fd645e100daad0650926372fc22bbdec1
Type fulltextMimetype application/pdf
Delrapport 2(850 kB)49 downloads
File information
File name FULLTEXT03.pdfFile size 850 kBChecksum SHA-512
545582e0e84ca0c1c1fd0469f2178eec43dc9bfd3fa99ab2db8757f768f0ebad81eb182a583e1751c3ff465ddec75b2224e87bbbfe0d2663471705b7adf69514
Type fulltextMimetype application/pdf
Delrapport 3(380 kB)48 downloads
File information
File name FULLTEXT04.pdfFile size 380 kBChecksum SHA-512
bf54e656904663b0db7199100412e7fc1dc3cf4c5a5a09ad175b65853e49049e63968c95c82a258da4375cca270d2e411cefb2fcc36717a31b52f9c8163bd732
Type fulltextMimetype application/pdf
Delrapport 4(196 kB)45 downloads
File information
File name FULLTEXT05.pdfFile size 196 kBChecksum SHA-512
bd03c3dc228ec6c3dee48073f36e9a2ae81bc980579b680d28b106b3532170e22e7c53f2d3c98cc794637eb2e659aabcebaca4ca993e68c9e1ebfafafeb00e4e
Type fulltextMimetype application/pdf
Delrapport 5(278 kB)63 downloads
File information
File name FULLTEXT06.pdfFile size 278 kBChecksum SHA-512
f5a54891d0e99abd7cd74d64881201fea3c33a81f0514f7e141b6e934d0c7244201d806eaa738ec6db4bc2f6cbe9c0862455565832f0ce3ebedaea8d82973c71
Type fulltextMimetype application/pdf
Delrapport 6(2499 kB)66 downloads
File information
File name FULLTEXT07.pdfFile size 2499 kBChecksum SHA-512
ea13763152a74d742592bbac464464f93bee9bc74afb9505934cf690f11f77527fdf2161d0cee2df83818ce011b24e62f8d83e38b588ce797090fef3bae2b4b3
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Afrah, HassanGotfryd, DanielHammarberg, ManneJohansson, VendelaKrook, ChristopherSkytt, NellieSmed, MajaVictorin, JakobWestin, Hugo
By organisation
Department of Physics and Astronomy
Electrical Engineering, Electronic Engineering, Information EngineeringPower Systems and ComponentsEnergy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 428 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 605 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf