Digitala Vetenskapliga Arkivet

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
En CFD-baserad Analys av Undervattenspumpkraftverket StEnSea: En systemtekniks studie av kavitationsfri drift, responstid och tillämpningsmöjlighet
Karlstad University, Faculty of Health, Science and Technology (starting 2013).
2025 (Swedish)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesisAlternative title
A CFD-Based Analysis of the Subsea Pumped Hydro Storage System StEnSea : A System Engineering Study of Cavitation-Free Operation, Response Time, and Application Potential (English)
Abstract [sv]

Förnybara energikällor minskar koldioxidutsläppet inom energisektor och det pågår idag en omfattande omställning av världens energisystem. För att bromsa utsläppstakten och möta det ökade energibehovet krävs dock en fortsatt expansion av de förnybara energikällorna. Waves4Power är ett företag som utvecklar förnybar energi från vågkraft. Tidigare anläggning vid Runde i Norge visade dock på utmaningar med energiunderskott och frekvensinstabilitet. Eftersom intermittent förnybar energi skapar obalans i elnätet krävs alltså integrerade energilagringssystem för att uppnå ett stabilt system där den fulla potentialen kan utnyttjas. Idag domineras lagringskapaciteten av pumpkraftverk, men dessa begränsas av krav på rätt topografi och stora landarealer. För att möta framtidens behov utvecklas därför alternativa lösningar som ’Stored Energy in The Sea’ (StEnSea), vilket är ett koncept där pumpkraftverket förflyttas till havsbotten. Systemet består av en betongsfär samt tekniska komponenter, som är placerade i en stålcylinder i sfärsaxeln. Denna stålcylinder kallas ’en tekniska enheten’. Turbomaskineriet i systemet är en pumpturbin och en back-up pump.

Rapporten syftar till att undersöka om StEnSeas lagringskoncept kan möta Waves4Powers lagringsbehov. Waves4Power efterfrågar en snabb frekvensreserv och ett stabilt system som kan hantera laddningscykler om 6–12 timmar. Målet är att genom CFD fastställa nödvändiga tryck i pump- och turbinläge för olika flödeshastigheter samt analysera kavitationsrisken. Målet är även att via CFD fastställa undervattenspumpkraftverkets responstider, som systemets tidskonstant och starttid, för att utröna tillämpningsmöjlighet. I studien undersöks även miljöpåverkan i jämförelse med ett Li-on batteri.

 

En förenklad modell av StEnSea systemet byggdes i CFD programmet COMSOL Multiphysics, där endast anslutningsröret modellerades. Anslutningsröret är en del av den tekniska enheten och är det rör som leder havsvattnet in och ut ur systemet via pumparna och turbinen. Modellen hade två olika dimensioner i höjdled och tre olika rördiametrar. En av dessa var anpassade efter en storskalig modell av StEnSea och två passade för implementeringen på Runde för djupen 100 och 200 m. Fyra olika driftfall undersöktes, tre i pumpläge och ett i turbinläge. Tre olika känslighetsanalyser utfördes för att utröna modellens påverkan av antagna värden.

 

Resultaten visade att systemet kan utformas utan risk för kavitation. För Runde kan vattennivån i sfären sänkas, utan kavitationsrisk, och således kan den användbara volymen ökas. För StEnSea krävdes en pumpeffekt mellan 889–2528 kW, och för Runde 100 m och 200 m krävdes en pumpeffekt på mellan 75–219 kW respektive 172–484 kW. Den levererade effekten är 722 kW, 63 kW och 151 kW för respektive system. I pumpläge är högre flödeshastigheter fördelaktiga för responstiden, men svarstiden ligger konsekvent över 1 minut. I turbinläge uppnås målhastigheten inom några sekunder. Tidskostanten för systemet är utanför gränsen för en snabb frekvensreserv i undantag från ett fall i turbinläge. Miljöanalysen visar att med hänsyn till materialets livslängd har StEnSea konceptet en påverkan som motsvarar 0,8 – 1,5 % av Li-on batteriets totala koldioxidutsläpp. 

 

Slutsatsen i rapporten är att StEnSea kan uppfylla Waves4Powers behov, då målet är tillämpa ett grönt lagringsystem med laddningscykler som hanterar dagsvariationer. Resultaten visar dock att systemet inte kan bidra med en stabilisering av frekvens såvida inte rätt förutsättningar ges, som att systemet redan är i drift i turbinläge. Slutsatsen blir därför att ytterligare lagringstyp, med snabbare svarstid, behöver inkluderas i energisystemet för att uppnå ett stabilt system med frekvensreglering. Resultaten visar också att modellen är känslig, vilket motiverar vidare analys av StEnSea konceptet för att erhålla tillförlitliga resultat.

Abstract [en]

Renewable energy sources reduce carbon emissions in the energy sector, and a large-scale transition of the global energy system is currently underway. To curb rising emission levels and meet increasing energy demand, further expansion of renewable sources is essential. Waves4Power is a company developing wave energy, but a previous installation at Runde, Norway, revealed challenges related to energy shortfalls and frequency instability. Since intermittent renewable energy causes imbalances in the power grid, integrated energy storage systems are required to ensure stable operation and utilize the full potential of renewable sources. Currently, storage is dominated by pumped hydro systems, which are limited by terrain and land use. To meet future demands, alternative solutions such as Stored Energy in the Sea (StEnSea), a seabed-based pumped hydro concept are being explored. The system consists of a concrete sphere and technical components, which are housed in a steel cylinder located along the sphere's axis. This steel cylinder is referred to as the 'technical unit'. The turbomachinery in the system includes a pump turbine and a back-up pump.

This thesis aims to examine whether StEnSea can meet Waves4Power’s storage requirements. Waves4Power seeks a fast frequency reserve and a stable storage solution capable of managing 6–12-hour charge-discharge cycles. The objective is to use CFD to determine the necessary pressures in pump and turbine modes for various flow velocities and assess cavitation risk. Additionally, the response times of the underwater pumped storage system, such as time constant and startup time, are evaluated to determine practical applicability. The study also includes an environmental comparison with a Li-ion battery.

A simplified model of the StEnSea system was built in the CFD software COMSOL Multiphysics, where only the connection pipe was modeled. The connection pipe is part of the technical unit and is the pipe through which seawater flows in and out of the system via the pumps and the turbine. The model incorporated two different vertical dimensions and three pipe diameters. One geometry represented a full-scale version of StEnSea, while the other two were adapted for installation at Runde at depths of 100 m and 200 m. Four operating scenarios were simulated—three in pump mode and one in turbine mode. However, three sensitivity analyses were conducted to assess the model’s dependence on assumed parameters.

The results show that the system can be designed to avoid cavitation. At the Runde site, the water level in the sphere can be lowered without inducing cavitation, thereby increasing the usable storage volume. Required pump power ranged from 889–2528 kW for the full-scale StEnSea system and from 75–219 kW and 172–484 kW for the 100 m and 200 m Runde cases, respectively. Delivered output was 722 kW, 63 kW, and 151 kW for each system. In pump mode, higher flow velocities were advantageous, though response times consistently exceeded one minute. In turbine mode, the target velocity was reached within seconds. Only one turbine scenario met the threshold for a fast frequency reserve. The environmental analysis shows that, considering material lifetime, StEnSea’s climate impact is only 0.8–1.5% of that of a Li-ion battery.

The study concludes that StEnSea could serve as a green storage solution suited to Waves4Power’s needs for daily variability. However, the system alone cannot ensure frequency stabilization unless already operating in turbine mode. Consequently, an additional storage solution with faster response time is necessary to achieve a frequency-stable system. The sensitivity of the model also indicates the need for further analysis to ensure reliable results.

Place, publisher, year, edition, pages
2025. , p. 56
Keywords [en]
Energy storage, Renewable energy, Frequency reserve, COMSOL
Keywords [sv]
Energilagring, förnybar energi, frekvensreserv, COMSOL
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:kau:diva-105631OAI: oai:DiVA.org:kau-105631DiVA, id: diva2:1974952
External cooperation
Waves4Power
Subject / course
Environmental and Energy Systems
Educational program
Engineering: Energy and Environmental Engineering (300 ECTS credits)
Supervisors
Examiners
Available from: 2025-08-04 Created: 2025-06-23 Last updated: 2026-02-12Bibliographically approved

Open Access in DiVA

fulltext(2352 kB)104 downloads
File information
File name FULLTEXT01.pdfFile size 2352 kBChecksum SHA-512
a166bba113a7981be3a2b882d951c3914651c4fb636e701483d91a9a4595187b92e0aecb2d16c46e3738e31238641d4b6cff9f5574e2d5bfec6bc895f878b56e
Type fulltextMimetype application/pdf

By organisation
Faculty of Health, Science and Technology (starting 2013)
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 106 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 384 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf