Digitala Vetenskapliga Arkivet

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Från F till effektiv: en multiparameterstudie av energieffektiva åtgärder för bostadsfastigheter från 1960-talet
University of Borås, Faculty of Textiles, Engineering and Business.
University of Borås, Faculty of Textiles, Engineering and Business.
2025 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesisAlternative title
From F to Efficient : A Multi-Parameter Study of Energy-Efficient Measures for Residential Buildings from the 1960s (English)
Abstract [sv]

Syftet med projektet är att utvärdera alternativ för energirenovering av fastigheterna för att minska energianvändningen och förbättra inomhusklimatet, i enlighet med Boverkets krav och EU-direktiv. Där alla byggnader i Sverige som omfattas av energideklarationskravet ska klassificeras utifrån A till G beroende på dess energiprestanda. Fokus ligger på att identifiera förbättringsåtgärder för bostadsfastigheter med låg energiklass, med särskild uppmärksamhet på värmesystem och ventilation. En detaljerad analys av två identiska flerbostadshus med energiklass F har genomförts. Simuleringar av olika energieffektiva åtgärder utfördes i programmet IDA ICE, där energibesparande metoder jämfördes inklusive tilläggsisolering, installation av FTX-system, bergvärmepump och solceller. Inomhusklimatet mättes i tre lägenheter inom bostadsområdet Kajan för att underbygga valet av ventilationsåtgärder. För att förbättra energiprestandan i genomfördes mätningar av fukthalt, inomhustemperatur, VOC och CO₂ i tre lägenheter på Hökvägen 6 under en vecka. Resultaten, sammanställda timvis i Excel, används för att välja ventilationsåtgärder. Boendeprotokoll registrerade användning av frånluftsfläktar och fönsteröppning. Mätningarna av inomhusklimatet visade höga halter av CO₂ och dessutom påvisade energideklarationen förhöjda halter av radon, vilket indikerar att förbättrad ventilation är lämpligt. Hökvägen 6 klassificerades initialt som energiklass F. Simuleringarna visade att tilläggsisolering förbättrade byggnadens energiklass till D, medan byggnader utan denna åtgärd och enbart bergvärmepump nådde energiklass E. Denna skillnad beror på att ett FTX-system drar energi, till skillnad från självdragsventilation, vilket innebär att energibesparingen inte blir lika stor utan tilläggsisolering. Installationen av bergvärmepumpar resulterade i den största förbättringen av energiklassen och visade hög energieffektivitet jämfört med fjärrvärmesystemet. Kombinationen av bergvärmepumpar och solceller optimerade byggnadens energimässiga självförsörjning. Effekten av tilläggsisolering framträdde som en kritisk åtgärd för förbättrad energiprestanda. Den rekommenderade kombinationen av FTX-system och tilläggsisolering maximerade energibesparingen och förbättrade inomhusklimatet. Trots höga initiala kostnader har dessa åtgärder potential att leda till långsiktiga besparingar och ökat fastighetsvärde. Tidiga investeringar i energieffektiviserande åtgärder är strategiskt fördelaktiga med tanke på potentiella framtida krav från EU. Resultaten från denna studie kan tillämpas på liknande byggnader, särskilt äldre lamellhus från 1960-talet, för att förbättra deras energieffektivitet och inomhusmiljö.

Abstract [en]

The purpose of the project is to evaluate options for energy renovation of the buildings in order to reduce energy consumption and improve the indoor climate, in accordance with Boverket’s requirements and EU directives. All buildings in Sweden must be classified from A to F depending on their energy performance. The focus is on identifying improvement measures for residential buildings with low energy ratings, with particular attention to heating systems and ventilation. A detailed analysis was carried out on two identical multi-family buildings with energy class F. Simulations of various energy-efficient measures were conducted using the software IDA ICE, where energy-saving methods were compared, including additional insulation, installation of a mechanical ventilation system with heat recovery (FTX), ground source heat pumps, and solar panels. Measurements of the indoor climate were carried out in three apartments in the Kajan residential area to support the choice of ventilation measures. To improve energy performance, measurements of humidity, indoor temperature, VOCs, and CO₂ were conducted in three apartments at Hökvägen 6 over one week. The results, compiled hourly in Excel, were used to select ventilation strategies. Resident logs recorded the use of exhaust fans and window opening. The indoor climate measurements showed high levels of CO₂, and the energy performance certificate also indicated elevated levels of radon, suggesting that improved ventilation is appropriate. Hökvägen 6 was initially classified as energy class F. The simulations showed that additional insulation improved the building's energy class to D, while buildings without this measure and with only a ground source heat pump reached energy class E. This difference is due to the fact that an FTX system consumes energy, unlike natural ventilation, meaning that energy savings are not as significant without additional insulation. The installation of ground source heat pumps resulted in the greatest improvement in energy class and demonstrated high energy efficiency compared to the district heating system. The combination of ground source heat pumps and solar panels optimized the building's energy self-sufficiency. The effect of additional insulation proved to be a critical measure for improved energy performance. The recommended combination of an FTX system and additional insulation maximized energy savings and improved the indoor climate. Despite high initial costs, these measures have the potential to lead to long-term savings and increased property value. Early investments in energy efficiency are strategically beneficial given potential future requirements from the EU. The results from this study can be applied to similar buildings, particularly older slab-block buildings from the 1960s, to improve their energy efficiency and indoor environment.

Place, publisher, year, edition, pages
2025.
Keywords [sv]
Energieffektivisering, energiklass, IDA ICE, inomhusmiljö, tilläggsisolering, ventilationssystem, värmesystem, omarbetade EU direktivet.
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:hb:diva-33707OAI: oai:DiVA.org:hb-33707DiVA, id: diva2:1972848
Subject / course
Energiteknik - Högskoleingenjör
Supervisors
Examiners
Available from: 2025-07-01 Created: 2025-06-19 Last updated: 2025-09-24Bibliographically approved

Open Access in DiVA

Arbete(3603 kB)314 downloads
File information
File name FULLTEXT01.pdfFile size 3603 kBChecksum SHA-512
5a9f8060e73d4c5e0c471896fdeeaa2d6ab26cf0675ac9da51a58c5033e0672b5e10c8529a6c190af292a0de69bc475d94950bd1ba96f07a0a9e270c198296f0
Type fulltextMimetype application/pdf

By organisation
Faculty of Textiles, Engineering and Business
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 316 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 376 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf