Syringeability of biomaterial microparticlesShow others and affiliations
2025 (English)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE credits
Student thesis
Abstract [en]
This report examines the syringeability of biomaterial microparticles in injectable suspensions, focusing onhow particle properties, fluid dynamics, syringe design, and formulation factors influence clogging, sedi-mentation, and injection failure. Syringeability refers to a formulation’s ability to be aspirated and expelledwithout clogging, excessive force, or inconsistent dosing, critical for safe and effective drug delivery. A the-oretical overview covers non-Newtonian flow, shear-dependent viscosity, and hydrodynamic interactions insyringes. Literature studies on Sculptra® (a PLLA-based dermal filler) show irregular, plate-like particleswith broad size distribution, raising clogging risk, especially in narrow-gauge needles. In contrast, spheri-cal, monodisperse particles align better with flow, enhancing injectability. Syringe and needle geometry areshown to be key factors. Optimal designs improve particle transport and reduce injection force. Larger nee-dle diameters reduce clogging but may increase discomfort. Injection rate had minimal impact: slower ratesslightly lowered force but raised sedimentation risk. The use of excipients such as carboxymethyl cellu-lose (CMC) improves dispersion but increases viscosity, raising injection force and clogging. Sterile wateris preferred, but suspension stability depends more on mixing and dissolving of the excipients, where the“Back-and-forth” method shows potential in enhancing homogeneity and delaying sedimentation. Shear-thinning suspensions are also ideal, maintaining particle suspension at rest while reducing flow resistance.Overall, the study concludes that syringeability is governed by an interplay of particle design, formula-tion, and device geometry. These insights provide a foundation for the development and optimization ofinjectable systems that balance clinical efficacy, patient comfort, and formulation stability.
Place, publisher, year, edition, pages
2025. , p. 27
Series
MATVET-K ; 25008
Keywords [en]
Syringeability, Biomaterial microparticles, Microparticle suspensions, Biostimulatory dermal fillers
National Category
Chemical Engineering
Identifiers
URN: urn:nbn:se:uu:diva-558514OAI: oai:DiVA.org:uu-558514DiVA, id: diva2:1964936
External cooperation
Galderma
Educational program
Master Programme in Chemical Engineering
Supervisors
Examiners
2025-06-302025-06-062025-06-30Bibliographically approved