Digitala Vetenskapliga Arkivet

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Electrospray ionisation suppression in aquatic dissolved organic matter studies: Investigation via liquid chromatography-mass spectrometry
Uppsala University, Disciplinary Domain of Science and Technology, Chemistry, Department of Chemistry - BMC, Analytical Chemistry.ORCID iD: 0000-0003-0664-2242
2024 (English)In: Organic Geochemistry, ISSN 0146-6380, E-ISSN 1873-5290, Vol. 196, article id 104852Article in journal (Refereed) Published
Abstract [en]

Ionisation suppression is a persistent issue in electrospray ionisation mass spectrometry, which decreases the signal of co-eluting analytes. In non-targeted analysis, where analyte and organic matrix identity is unknown, this poses a very challenging analytical problem when it comes to quantitatively assessing differences between samples, including in a compositional sense. In this study, I demonstrate the problems that arise due to ionisation suppression using a very simple sample mixing scheme between a fresh, metabolite rich sample (a leaf leachate) and a forest pond water. Samples were analysed after solid phase extraction on Agilent PPL and using high performance liquid chromatography coupled to electrospray ionisation - Orbitrap mass spectrometry, charged aerosol detector and diode array detector, the latter two allowing quantification of eluting material. I found that more than half of the well-resolved analytes expected to be present (at equal concentration) were completely lost from detection after mixing with pond water DOM. The average recovery of analytical signal (i.e., the signal weighted average), was about 50%, and was highly variable between analytes. Ionisation suppression also affected the signal obtained from the geochemical background DOM, and material recovery decreased slightly when mixing samples and extracting at a higher volume on PPL. Overall, the results showed that ionisation suppression is an extremely important problem for comparison of biogeochemical samples, even when only considering presence and absence of detected features. A multi detector approach and liquid chromatographic separation adds great value in comparison to use of only high resolution mass spectrometry (in direct infusion mode).

Place, publisher, year, edition, pages
Elsevier, 2024. Vol. 196, article id 104852
Keywords [en]
Ionisation suppression, Electrospray ionisation, Mass spectrometry, Liquid chromatography, Charged aerosol detector, Dissolved organic matter, Leaf leachate, Formula assignment, Feature detection
National Category
Analytical Chemistry
Identifiers
URN: urn:nbn:se:uu:diva-538198DOI: 10.1016/j.orggeochem.2024.104852ISI: 001303076800001OAI: oai:DiVA.org:uu-538198DiVA, id: diva2:1897302
Part of project
Single compound approaches to investigate environmental processing of dissolved organic matter, Swedish Research Council
Funder
Swedish Research Council, 2018-04618Available from: 2024-09-12 Created: 2024-09-12 Last updated: 2024-09-12Bibliographically approved

Open Access in DiVA

fulltext(1563 kB)310 downloads
File information
File name FULLTEXT01.pdfFile size 1563 kBChecksum SHA-512
7f14703803c86b034da0f15273f6f148e6ee7ea37079436983b3e6bbe10415b7afccbfa854fccd1d95bcb120515fe3345f3656360e457120b469def4da5fcd76
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Search in DiVA

By author/editor
Hawkes, Jeffrey A.
By organisation
Analytical Chemistry
In the same journal
Organic Geochemistry
Analytical Chemistry

Search outside of DiVA

GoogleGoogle Scholar
Total: 310 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 523 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf