Effekt av stålstabiliseringssystem på prestanda av flervåningsbyggnader i stål
2024 (Swedish)Independent thesis Advanced level (professional degree), 10 credits / 15 HE credits
Student thesisAlternative title
Effect of different bracing systems on the structural performance of multi-story steel buildings (English)
Abstract [en]
In recent centuries, there has been a growth in the population of larger cities, where buildings have started to be constructed vertically to preserve green spaces. This has led to higher exposure to wind loads, which buildings need to be stabilized against. Steel stabilization systems are used to stabilize structures against horizontal loads such as earthquakes and wind. Common designs used for multi-story buildings and examined in this study include X-, V-, inverted V-, and diagonal designs. The diagonal design is also examined in an additional variant, referred to as the Z-design.
The choice of which design to use for an optimized structure can depend on several different factors, some of which include the amount of material, cost, and performance of the structure. Without the dimensioning and analysis of the stabilization systems based on aspects of performance, material consumption and cost, the choice of stabilization system can lead to weak stabilization capability or over-dimensioning, which in turn leads to increased material consumption and cost. The purpose of this work is to develop a technical basis for an optimized construction based on the aforementioned factors. The purpose will be achieved through sub-goals which involve calculating loads, dimensioning and modeling of stabilization systems and also comparing material consumption, cost, and performance of the different stabilization systems.
The modeling of construction systems with different designs was conducted in the SAP2000 program, while calculations of loads, dimensioning of elements and calculations of material quantities and costs were carried out in MathCad. The obtained data is then used to conduct a comparison and analysis to identify the design that isoptimal in terms of performance, material consumption and cost.
The inverted V-design was found to be the optimal based on an overall assessment considering performance, material quantity and cost. Although the V-design is the cheapest and the X-design results in high performance, the inverted V-design was the optimal solution due to its low cost and material consumption as well as high performance. The diagonal design has weak stabilization capability and relatively high cost and could directly be excluded as the optimal design. Similarly, the Z-design could also be excluded as the optimal design due to its high cost and relatively weak stabilization capability.
Place, publisher, year, edition, pages
2024. , p. 44
Keywords [en]
bracing, performance, stabilization, stabilization system, horizontal loads, wind load, material consumption, material cost
Keywords [sv]
stagning, prestanda, stabilisering, stabiliseringssystem, horisontella laster, vindlast, materialåtgång, materialkostnad
National Category
Other Civil Engineering
Identifiers
URN: urn:nbn:se:lnu:diva-132262OAI: oai:DiVA.org:lnu-132262DiVA, id: diva2:1895533
Subject / course
Byggteknik
Educational program
Civil Engineering Programme, Building and Construction, 180 credits
2024-09-092024-09-052024-09-09Bibliographically approved