In recent decades, new techniques have been developed to produce concrete. Such a technology is self-compacting concrete (SCC) and another is 3D-printed concrete. In both cases, compaction through vibration, which is a labour-intensive moment, is omitted. In the present research project, both techniques have been combined. Traditionally, concrete columns are produced by pouring concrete into a column mould or form that is either made of wood or steel. The steel mould can be used many times while the wooden mould can at best be used maybe two or three times. Building and then dismantling the formwork takes time and costs money. It also leads to increased material use and increased transport. An alternative is columns with a lost form. Steel pipe columns filled with concrete is a proven technique, but it is rarely used. The steel must be protected from corrosion and in buildings also fire protected. A new alternative – which is being studied in the present project – is a lost 3D-printed concrete form in which a core of SCC is cast.
The project included load tests on four composite and two homogeneous concrete columns. The columns were 3 m high and had a circular cross-section with a diameter of 300 mm. The composite columns consisted of a 40 mm thick, 3D-printed concrete form that was filled with SCC. The homogeneous columns were cast with the same SCC. All columns were reinforced with four vertical F8 mm bars and ten stirrups F5 mm. In the load tests, the compressive strength was 56 and 44 MPa for the concrete for the 3D-printed forms, respectively. the self-compacting concrete.
The composite columns achieved failure loads as high as the corresponding homogeneous columns. However, there was a difference between columns whose entire cross section was loaded (Group A) and columns where only an inner part (corresponding to the size of the SCC core) of the cross section was loaded (Group B). The failure load for Group B was only 60% of the failure load for Group B. A possible reason for the difference is that the eccentricity was greater in the cases where only a smaller part of the cross section was loaded.
Concrete for 3D printing today has a small maximum aggregate size, which leads to more cement paste. Normally, the water-cement ratio (w/c) is also low. It gives high cement contents but, on the other hand, the possibility of a dense concrete. Dense concrete generally provides good durability. In the project, the conditions for using the 3D-printed concrete form as concrete cover were investigated. It was done by frost testing and testing resistance to carbonation and chloride migration. The frost test showed "good frost resistance" on the border of "very good frost resistance". The resistance to carbonation was comparable to the resistance of other concretes of the same w/c. The measured resistance to chloride migration, on the other hand, was worse. This is probably because the thickness of the printed form varies (thickest in the middle of a layer and thinnest between two layers). The tightness of the joint between two layers is possibly also lower than the tightness of a layer.
The general conclusion is that the technology of columns with lost 3D-printed concrete forms filled with SCC is promising. The report concludes with half a dozen suggestions for further research.
Stockholm: KTH Royal Institute of Technology, 2024. , p. 68
Composite columns, 3DP concrete, Self-compactiong concrete, Loading tests, Durability tests