Influence of upstream blockage on smoke control in tunnel fires
RISE Research Institutes of Sweden, Safety and Transport, Fire and Safety.ORCID iD: 0000-0001-7744-2390
RISE Research Institutes of Sweden, Safety and Transport, Fire and Safety.ORCID iD: 0000-0002-9340-6768
2024 (English)In: Fire safety journal, ISSN 0379-7112, E-ISSN 1873-7226, Vol. 147, article id 104197Article in journal (Refereed) Published
Abstract [en]

Smoke control in a longitudinally ventilated tunnel with various blockage conditions was investigated experimentally. A total of 28 tests were conducted with a focus on single blockage with a short distance from the fire source, although continuous blockage and semicontinuous blockage were also discussed. Both gas and pool fires were used. The aim was to understand the influence of upstream blockage on critical velocity and babcklayering length. The results confirm that blockage ratio is a critical parameter when determining the critical velocity and backlayering length. The longitudinal location of the blockage in relation to the fire source also influences the values of critical velocity and backlayering length. The experiments presented are in scale 1 to 3.3, representing a medium sized tunnel. The focus was on free flow conditions and blockage ratios of regular sizes. For the various tested scenarios with single blockage, the reduction ratio of critical velocity appears to be slightly less than the blockage ratio. However, when the blockage is attached to the upstream side of the fire source, the reduction ratio of critical velocity approximately equals the blockage ratio. 

Place, publisher, year, edition, pages
Elsevier Ltd , 2024. Vol. 147, article id 104197
Keywords [en]
Smoke; Smoke abatement; Back-layering length; Backlayering; Blockage; Blockage ratio; Critical velocities; Medium scale tunnel; Medium-scale; Reduction ratios; Smoke control; Tunnel fires; Fires
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:ri:diva-74639DOI: 10.1016/j.firesaf.2024.104197Scopus ID: 2-s2.0-85196764271OAI: oai:DiVA.org:ri-74639DiVA, id: diva2:1887189
Note

This work was financially supported by the Tunnel and Underground Safety Center (TUSC), which is gratefully acknowledged.

Available from: 2024-08-07 Created: 2024-08-07 Last updated: 2025-09-23Bibliographically approved

Open Access in DiVA

fulltext(2044 kB)167 downloads
File information
File name FULLTEXT01.pdfFile size 2044 kBChecksum SHA-512
2b9de8e57e972624c2f6752b705dae0dcd49356ee7a3e97f24a0c305444edb91e8e339baef65c5260d97f766302bb76f178d7cbdf346b4a720472435cae16a6a
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Li, Ying ZhenIngason, Haukur
By organisation
Fire and Safety
In the same journal
Fire safety journal
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 168 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 370 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf