Jämförelse av olika metoder för att skydda ändträ i KL-träskivor mot fuktinträngning
2024 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE credits
Student thesisAlternative title
Comparison of different methods for protecting the narrow face in CLT wall elements against moisture (English)
Abstract [en]
When building in cross-laminated timber (CLT) today, there are two alternatives to protect the wood against moisture during the construction phase. Either comprehensive weather protection such as tents or local weather protection methods is used in the most exposed areas such as the narrow face of the CLT panels. The reason why wood needs to be protected from water exposure during construction, is to minimize the risk of microbial growth in timber. At moisture content above 18% the probability of microbial growth is high, if the wood cannot dry-out within a certain time. Thus, the maximum permitted moisture content that may be built in must be 18% or lower to minimize the risk for microbial growth.
If local weather protection is used, the narrow face and adjacent side face is commonly sealed by tape. However, if the CLT should be visible in the finished building, this tapping method is unsuitable due to visual aspects. Alternatively, only the narrow face could be taped, or transparent coatings could be used.
In order to investigate how well these different protection methods prevent moisture from intrusion into the material, an experimental study was carried out. In the experiments two taping methods were examined together with two coating methods. The four protection methods were tested and compared in a controlled laboratory environment where moisture content is measured with an electrode and permanent moisture sensors that measure temperature and relative humidity. To investigate whether the protection methods are more effective than building without any protection, an unprotected reference test specimen was added as well. The experiments lasted two and a half weeks, at which the CLT narrow face was in permanent water contact, to mimic the time for which the wood might be exposed to water during the construction process. The experiments aimed in measuring the moisture content in CLT wall element close to the narrow faces, and in measuring how high the moisture rises in the material during the time of water exposure, and thus should indicate on how efficient the various protection methods are. The latter was done by measuring the moisture content at different determined heights from the narrow face. The efficiency of the protection methods was evaluated by comparing the moisture content between the different methods, and by comparing the moisture content threshold of 18% for microbial growth. This resulted in two of the four protection methods having moisture content above 18%, which means that they must have the possibility to dry-out within a certain time. The most effective protection method was found to be the common taping method where the tape is added at the narrow face and folded up on the side face of the CLT wall. Furthermore, promising results were found for the two coating methods, while the moisture content for only narrow face taped method and the unprotected CLT was well above the 18% threshold.
Place, publisher, year, edition, pages
2024. , p. 34
Keywords [en]
cross-laminated timber, moisture, moisture safety, narrow face, weather protection
Keywords [sv]
korslimmat-trä, fukt, fuktsäkerhet, ändträ, väderskydd
National Category
Construction Management Building Technologies
Identifiers
URN: urn:nbn:se:lnu:diva-131565OAI: oai:DiVA.org:lnu-131565DiVA, id: diva2:1886217
External cooperation
Södra
Educational program
Civil Engineering Programme, Building and Construction, 180 credits
Supervisors
Examiners
Note
Projekt: Hållbart byggande med trä – materialeffektivt värdeskapande från trämaterial till byggnader
2024-08-142024-07-302026-03-12Bibliographically approved