Dynamic Analysis of major elements in biological tissue validating quantification of trace life elements in MeV ion beam microscopyUniv Louisiana Lafayette, Louisiana Accelerator Ctr, POB 43680, Lafayette, LA 70504 USA.;Univ Louisiana Lafayette, Dept Phys, POB 43680, Lafayette, LA USA.;Louisiana State Univ Hlth Shreveport, Shreveport, LA 71103 USA..
Univ Louisiana Lafayette, Louisiana Accelerator Ctr, POB 43680, Lafayette, LA 70504 USA..
Univ Louisiana Lafayette, Louisiana Accelerator Ctr, POB 43680, Lafayette, LA 70504 USA.;Univ Louisiana Lafayette, Dept Phys, POB 43680, Lafayette, LA USA.;Columbia Univ, Ctr Radiol Res, Radiol Res Accelerator Facil, Irvington, NY 10533 USA.;Columbia Univ, Ctr Radiol Res, New York, NY 10032 USA..
Univ Louisiana Lafayette, Dept Biol, POB 43602, Lafayette, LA 70504 USA..
Kasetsart Univ, Fac Sci, Dept Appl Radiat & Isotopes, Bangkok 10900, Thailand..
Kasetsart Univ, Fac Vet Technol, Dept Vet Technol, Bangkok 10900, Thailand..
Kasetsart Univ, Fac Vet Technol, Dept Vet Technol, Bangkok 10900, Thailand..
Natl Univ Singapore, Ctr Ion Beam Applicat, Singapore 117551, Singapore..
Natl Univ Singapore, Ctr Ion Beam Applicat, Singapore 117551, Singapore..
CSIRO Mineral Resources, Clayton, Vic 3168, Australia..
Univ Louisiana Lafayette, Dept Biol, POB 43602, Lafayette, LA 70504 USA.;Univ Louisiana Lafayette, New Iberia Res Ctr, POB 13610, New Iberia, LA 70562 USA..
Show others and affiliations
2024 (English)In: Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, ISSN 0168-583X, E-ISSN 1872-9584, Vol. 554, article id 165411Article in journal (Refereed) Published
Abstract [en]
MeV ion microprobe measurements of the lesser and trace life element concentrations in biological tissues are challenging because of complex spatial inhomogeneities in these types of samples. Measurements on ex vivo tissue sections require determination of the matrix element composition and the tissue section thickness. For these reasons, in this work, we adapted the Dynamic Analysis approach known from literature, to interpret the MeV ion microscopy data to determine concentrations of H, C, O, and N as well as the thickness of different tissue regions in Non Human Primate (NHP) mesenteric lymph node section. The results showed no strong variations of the matrix element contents regardless of section thickness variations in the tissue. The matrix information was used to quantify total-Ca molarities and a significant ∼30 mM Ca concentration hotspot was observed at the edge of sinus structure in the mesenteric lymph node as compared to the 3-4 mM total-Ca levels in the surrounding tissues. Thus, MeV ion microprobe imaging combined with dynamic analysis comprise a novel chemometric approach paving a way for quantitative analysis of similarly complicated animal and plant biological tissue sections.
Place, publisher, year, edition, pages
Elsevier, 2024. Vol. 554, article id 165411
Keywords [en]
Ion beam analysis, MeV ion microbeams, Biological tissue, Elemental maps, Major elements, Trace life elements, Ca molarity, Mesenteric lymph node