Digitala Vetenskapliga Arkivet

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Parametric study on the dynamics of end-shield railway bridges including soil-structure interaction
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Structural Engineering and Bridges.
2024 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesisAlternative title
Parametrisk studie om dynamik av ändskärmsbroar inklusive jord struktur interaktion (Swedish)
Abstract [en]

As train speeds increase to transport passengers quicker across Sweden, the existingrailway bridge network must be verified for the greater vertical accelerations imposedby faster trains. As future railways are being built, understanding the effects thatparameters have on the acceleration response is of importance. The aim of this thesisis to perform a parametric study on end-shield bridges, including the soil-structureinteraction (SSI), when exposed to large dynamic loads.To conduct the parametric study, a script capable of generating arbitrary 2D bridgegeometries was created. To analyze the response of the bridges, frequency responsefunctions were generated for each bridge and the associated acceleration responseenvelopes were created. These envelopes were generated by simulating train passagesusing the the high speed load model. The script was verified against a 3D model withgood frequency matching but with damping error present. The SSI was first calculatedusing distributed springs and dashpots, and then represented using impedancefunctions. The parameters studied were: number of spans, the height between theend-shield and bedrock, end-shield size, and beam ratios.Single span bridges met the dynamic requirement set forth by governing standards.Three span bridges failed this criteria for a beam ratio of 15 and a span length lessthan 22 meters. In the single span case, larger end-shields outperformed smaller endshields, and a deeper bedrock foundation helped the end-shields dissipate vibrations from the structure. For the three span case, the presence of an end-shield reduced the acceleration but a greater height to bedrock had little effect.

 

Place, publisher, year, edition, pages
2024.
Series
TRITA-ABE-MBT ; 24626
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-350444OAI: oai:DiVA.org:kth-350444DiVA, id: diva2:1883981
External cooperation
ELU Konsult
Supervisors
Examiners
Available from: 2024-07-12 Created: 2024-07-12

Open Access in DiVA

fulltext(13128 kB)445 downloads
File information
File name FULLTEXT01.pdfFile size 13128 kBChecksum SHA-512
776b9bd2043540162d1b48d026e4dfc46405ce2b80e7c9ff2c00b76ad440196b21f4484445702ee58b296b741fbd6d4075583e754601085defbdbe641d5b49e3
Type fulltextMimetype application/pdf

By organisation
Structural Engineering and Bridges
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 446 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 552 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf