Designing the electricity grid in a new city district in Uppsala: Assessing voltage with regards to cable types and solar power penetration
2024 (English)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE credits
Student thesis
Abstract [en]
Alongside society’s development and growth, the demand for electrical energy used for housing projects is constantly growing. To accommodate this demand in a new district in Uppsala, a stable and functioning electrical grid is vital. The electrical grid’s voltage level is primarily a result of the net load (electrical energy consumption - production). To analyze the voltage level with different assumptions regarding solar power capacity and cables in the electricity grid, power-flow simulations are conducted in a medium voltage network. This is done by comparing three cable types and different PV penetration levels during July and January. These months represent periods with the highest and lowest solar radiation potential and were hence chosen. The PV levels are also compared to the district's yearly energy consumption to determine if self-sufficiency is possible given the voltage level variations which PV implementation leads to. Solar power production corresponding to the yearly energy demand will not inflict unbearable damage or strain to the electrical grid as long as a cable type with a high max current and low resistance is installed. When conducting simulations with different cables and PV inputs and comparing them it is clear that cable types with higher max current and lower resistance are the appropriate option, given the effect on the voltage level. Furthermore, installing solar power for self-sufficiency on a yearly basis is inefficient since it results in an excess of electrical solar production in the summer. The excess production corresponds to nearly 5 times the district's consumption during the summer. Also, it leads to an insufficient amount of electrical production in some winter periods. Summarized, using cables with properties such as high current and low resistance seem to be the best option alongside an implementation of solar power that does not lead to excess electricity production. This is because the disruption in regards to voltage level is minimized and almost no electricity that is produced is wasted. When conducting the simulations for every sector in the district, the worst performing cable results in voltage levels that fall out of the accepted criteria of +-3% from nominal voltage in almost 20 out of 23 sectors. The best performing cable results in voltage levels that are always within the criteria of +-3% of nominal voltage.
Place, publisher, year, edition, pages
2024. , p. 43
Series
SAMINT-STS ; 24004
Keywords [en]
Designing electricity grid, cable types, new city district, SÖS, voltage, solar power
Keywords [sv]
Designa elnätet, kabeltyper, ny statsdel, SÖS, spänning, solkraft
National Category
Civil Engineering
Identifiers
URN: urn:nbn:se:uu:diva-534896OAI: oai:DiVA.org:uu-534896DiVA, id: diva2:1883603
External cooperation
Uppsala Kommun
Educational program
Systems in Technology and Society Programme
Supervisors
Examiners
2024-07-112024-07-112024-08-16Bibliographically approved