Clinical validation of a capnodynamic method for measuring end-expiratory lung volume in critically ill patients
Show others and affiliations
2024 (English)In: Critical Care, ISSN 1364-8535, E-ISSN 1466-609X, Vol. 28, no 1, article id 142Article in journal (Refereed) Published
Abstract [en]

Rationale

End-expiratory lung volume (EELV) is reduced in mechanically ventilated patients, especially in pathologic conditions. The resulting heterogeneous distribution of ventilation increases the risk for ventilation induced lung injury. Clinical measurement of EELV however, remains difficult.

Objective

Validation of a novel continuous capnodynamic method based on expired carbon dioxide (CO2) kinetics for measuring EELV in mechanically ventilated critically-ill patients.

Methods

Prospective study of mechanically ventilated patients scheduled for a diagnostic computed tomography exploration. Comparisons were made between absolute and corrected EELVCO2 values, the latter accounting for the amount of CO2 dissolved in lung tissue, with the reference EELV measured by computed tomography (EELVCT). Uncorrected and corrected EELVCO2 was compared with total CT volume (density compartments between − 1000 and 0 Hounsfield units (HU) and functional CT volume, including density compartments of − 1000 to − 200HU eliminating regions of increased shunt. We used comparative statistics including correlations and measurement of accuracy and precision by the Bland Altman method.

Measurements and main results

Of the 46 patients included in the final analysis, 25 had a diagnosis of ARDS (24 of which COVID-19). Both EELVCT and EELVCO2 were significantly reduced (39 and 40% respectively) when compared with theoretical values of functional residual capacity (p < 0.0001). Uncorrected EELVCO2 tended to overestimate EELVCT with a correlation r2 0.58; Bias − 285 and limits of agreement (LoA) (+ 513 to − 1083; 95% CI) ml. Agreement improved for the corrected EELVCO2 to a Bias of − 23 and LoA of (+ 763 to − 716; 95% CI) ml. The best agreement of the method was obtained by comparison of corrected EELVCO2 with functional EELVCT with a r2 of 0.59; Bias − 2.75 (+ 755 to − 761; 95% CI) ml. We did not observe major differences in the performance of the method between ARDS (most of them COVID related) and non-ARDS patients.

Conclusion

In this first validation in critically ill patients, the capnodynamic method provided good estimates of both total and functional EELV. Bias improved after correcting EELVCO2 for extra-alveolar CO2 content when compared with CT estimated volume. If confirmed in further validations EELVCO2 may become an attractive monitoring option for continuously monitor EELV in critically ill mechanically ventilated patients.

Trial registration: clinicaltrials.gov (NCT04045262).

Place, publisher, year, edition, pages
BioMed Central (BMC), 2024. Vol. 28, no 1, article id 142
National Category
Anesthesiology and Intensive Care
Identifiers
URN: urn:nbn:se:uu:diva-534573DOI: 10.1186/s13054-024-04928-wISI: 001249134100001PubMedID: 38689313Scopus ID: 2-s2.0-85191851211OAI: oai:DiVA.org:uu-534573DiVA, id: diva2:1882312
Note

Correction in: CRITICAL CARE, Volume28, Issue 1, 2024

DOI10.1186/s13054-024-04984-2

Available from: 2024-07-05 Created: 2024-07-05 Last updated: 2025-02-20Bibliographically approved

Open Access in DiVA

fulltext(1489 kB)98 downloads
File information
File name FULLTEXT01.pdfFile size 1489 kBChecksum SHA-512
7aad1dac18d32b69dfbb2d67a2e812ffc05bc70ab24fc8796861be5161910e72d9ae6faff751580eb83236138aa7af5056000a74d0de5ed0abe6898e3f36668f
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMedScopus

Search in DiVA

By author/editor
Suarez-Sipmann, Fernando
By organisation
Hedenstierna laboratory
In the same journal
Critical Care
Anesthesiology and Intensive Care

Search outside of DiVA

GoogleGoogle Scholar
Total: 99 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 275 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf