Implant and Prosthesis Failure Rates with Mini-Implant-Supported Overdentures - A Systematic Review
2024 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE credits
Student thesis
Abstract [sv]
Syfte. Att bedöma kliniska och röntgenologiska utfall av mini-implantatstödda täckproteser baserad på en systematisk översikt.
Material och metod. Elektronisk sökning genomfördes i tre databaser, senast uppdatering januari 2024, samt manuell sökning i tidskrifter. Den kumulativa mini-implantatöverlevnaden (CSR: Cumulative implant survival rate) och den uppskattade marginala bennivån (MBL:marginal bone loss) under olika uppföljningstider beräknades.
Resultat. Trettionio studier inkluderades, med 3787 miniimplantat som stödde 1026 täckproteser (109 i maxillan och 917 i mandibeln) hos 1005 patienter med en medeluppföljningstid på 28.1±19.8 månader (min-max 0,3–84,0). 202 mini implantat misslyckades, efter en genomsnittlig tid på 9.4±11.8 månader (7 års CSR 91,4%). Implantatöverlevnaden var lägre i maxillan jämfört med mandibeln (p <0,001; Log-rank-test). En hög frekvens av tvärfrakturer av täckproteser och slitage av fästen observerades. Den uppskattade medel-MBL ökade gradvis från 0,518 (≤6 månader) till 1,260 mm (58,8–90 månader). Det fanns en uppskattad MBL-ökning med 0,011 mm per ytterligare månad vid uppföljning.
Slutsats. Trots att resultat på 7 års uppföljningstid visar på en hög överlevnad för miniimplantat och proteser, krävs det frekventa uppföljningar på grund av den höga förekomsten av tekniska komplikationer. De tekniska komplikationerna gällde både mini-implantat och täckprotes. De vanligaste problemen var slitage av förankringssystemen, oftast på täckprotesen, men även på mini-implantaten samt tvärfrakturer av täckproteserna och behov av rebasering.
Abstract [en]
Purpose. To assess the clinical and radiographic outcomes of overdentures and their retaining dental mini-implants, based on a systematic review of the literature.
Methods. Electronic search was undertaken in three databases, last updated in January 2024, plus manual search of journals. Cumulative implant survival rate (CSR) and the estimated MBL under different follow-up times were calculated.
Results. Thirty-nine studies were included, with 3,787 mini-implants supporting 1,026 overdentures (109 maxilla, 896 mandible) in 1,005 patients, with a mean follow-up of 28.1±19.8 months (min-max 0.3-84.0). 202 mini-implants failed, after a mean of 9.4±11.8 months (7-year CSR 91.4%). The implant survival was lower in the maxilla in comparison to the mandible (p<0.001), lower for early/delayed-loaded in comparison to immediately-loaded implants (p=0.005) and lower for 2-mini-implant in comparison to 4-mini-implant-retained mandibular overdenture (p<0.001; Log-rank test). A high rate of transversal fracture of the prosthesis and wear of the attachment parts was observed. The estimated mean MBL gradually increased from 0.518 (≤6 months) to 1.260 mm (58.8-90 months). There was an estimated MBL increase of 0.011 mm per additional month of follow-up.
Conclusion. Although presenting a high 7-year CSR, mini-implant-retained overdentures may require frequent maintenance follow-ups, due to the high rate of technical complications. The technical complications occurred in both the mini-implants and overdentures. The most prevalent issue was worn in the attachment systems, primarily on the overdentures but also in the mini-implantstransverse fractures and the necessity for denture rebase procedures were observed in the overdentures.
Place, publisher, year, edition, pages
2024. , p. 36
National Category
Dentistry
Identifiers
URN: urn:nbn:se:mau:diva-69764OAI: oai:DiVA.org:mau-69764DiVA, id: diva2:1881851
Educational program
OD Tandläkarutbildning
Supervisors
Examiners
2024-07-162024-07-042024-07-18Bibliographically approved