Energikartläggning hos Surahmmars Bruk AB: Nyckeln till ökad energieffektivitet för hållbara företag
Mälardalen University, School of Business, Society and Engineering, Future Energy Center.
Mälardalen University, School of Business, Society and Engineering, Future Energy Center.
2024 (Swedish)Independent thesis Basic level (professional degree), 180 HE creditsStudent thesis
Abstract [en]

This study was conducted at Surahammars Bruk AB, focusing on enhancing the energy efficiency of the steam plant, a critical aspect due to historical high electricity costs and the plant’s outdated infrastructure. The objective was to identify significant energy losses and propose effective measures to reduce these losses, thereby optimizing the plant's overall energy consumption. The methodology included a comprehensive energy mapping combined with the use of advanced analytical tools such as Grafana and iba Analyzer for data collection and analysis. The investigation revealed substantial energy wastage due to poor insulation of steam pipes and outdated systems. It was determined that up to two kilometers of steam piping were inadequately insulated, contributing to considerable thermal losses. Furthermore, significant energy was lost due to condensation processes within the steam pipes. Based on these findings, the study suggests that implementing improved insulation techniques and upgrading to modern, energy-efficient steam boilers could lead to significant reductions in energy consumption and costs. The conclusion emphasizes that by addressing these identified inefficiencies, Surahammars Bruk AB can significantly enhance its energy efficiency, reduce operational costs, and contribute to environmental sustainability.

Place, publisher, year, edition, pages
2024. , p. 66
Keywords [en]
Energy Audit, Energy, Energy efficiency, Direct Steam Injection, DSI, Surahammars Bruk AB, Insulation
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:mdh:diva-68011OAI: oai:DiVA.org:mdh-68011DiVA, id: diva2:1881818
Subject / course
Energy Engineering
Presentation
2024-05-31, Mälardalens Universitet, Hus R, Rum: R1-306, Högskoleplan 1, 722 14, Västerås, 13:20 (Swedish)
Supervisors
Examiners
Available from: 2024-07-05 Created: 2024-07-03 Last updated: 2025-10-10Bibliographically approved

Open Access in DiVA

fulltext(3892 kB)361 downloads
File information
File name FULLTEXT01.pdfFile size 3892 kBChecksum SHA-512
0600108a6d3b9ff582fc1117e5b2afc011489c982321c374a7acdb923c68c7eda1e094ea20b9f3e0c2871c4badfab25b9dce2918abb73a09ad3ede17bfbecf36
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Ntambwe, Benjamin MbiyaYazar, Mehmet
By organisation
Future Energy Center
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 365 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 630 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf