The need for heat pumps is increasing in order to reduce emissions andachieve sustainable home comfort solutions. The large number of appliances using refrigeration circuits means a substantial amount of energy is consumed, which also means making them more effective can have a substantial impact. Good control is crucial to make a heat pump for effective. Controlling the degree of superheat in the refrigeration circuit could have a large impact on the efficiency and it is important to have control of it to maintain stable operation and also protect the compressor. The control of the superheat is mainly done by opening and closing the electronic expansion valve.
The study was conducted by creating a PID controller and several versions of fuzzy controllers. These were implemented in a Matlab Simulink model, this model of contained everything to control the heat pump. The brine source heat pump with a rated maximum heating output of 8 kW was run with the Simulink models while connected to a rig that supplied the heatpump with the specified flows and temperatures of the water and brine. Fuzzy control for heat pump application showed faster response time but also larger overshoots than that of the PID controller that was tuned with Ziegler-Nichols rules. However, it was also seen that the Ziegler-Nichols method was not suitable for this application. It was also seen that both control methods showed shorter stabilization times when doing a step upof the set point for the suction superheat. It was observed that the opening of the expansion valve did not fluctuate to the same extent as the fuzzy controllers. This was attributed to the low control input from the PID controller.
Since the Ziegler-Nichols method of tuning a PID for this application wasshown to not be sufficient further work on this would be to compare the fuzzy controller with a better tuned PID or any other control methods. Also, it would be interesting to create the cascaded fuzzy-PID controller.