UTVÄRDERING AV BRANDSKYDDSMÅLAD PANEL: Utvärdering av brandskyddsfärg på tidigare måladeträpaneler inomhus
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Structural and Fire Engineering.
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Structural and Fire Engineering.
2024 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Examensarbetets syfte är att undersöka vilka skillnader i skyddsnivå som brandskyddsfärg ger vidbrandexponering beroende på underliggande träpanels tidigare ytbehandling. Genom två separata försöksuppställningar kunde det uttydas att om en träpanel sedan tidigare ärytbehandlad kan det påverka brandskyddsfärgens förmåga att skydda mot brand. Dessa tvåförsökuppställningar visade att den studerade brandskyddsfärgen ger bäst brandskyddsförmåga om denappliceras likt fabrikatörens anvisningar, alltså på en obehandlad träyta. Arbetet visade dock att träpanelerna behandlade med brandskyddsfärg på akrylatfärg enbart visade en relativt liten försämringvid jämförelser med träpanelen utförd enligt fabrikatörens anvisning för de utförda experimenten. Större skillnader kunde påvisas då prov behandlat med linoljefärg gav större försämringar ibrandskyddsfärgens förmåga att motverka pyrolys i det underliggande trämaterialet. Resultaten indikerat att även om man har en underliggande ytbehandling så motverkarbrandskyddsfärgen antändning, fortskridande brandspridning längs med träytan, rökproduktion och effektutvecklingen efter antändning.

Abstract [en]

The purpose of this thesis is to identify the differences in protection that the intumescent paint provides in relation to fire, depending on prior surface finishes.Through two separate experimental setups, it was deduced that if a wood panel has undergone prior surface treatment, it can have a significant impact on the intumescent paint's ability to protect against fire. These two experimental setups demonstrated that the intumescent paint exhibits the best fireprotection capability when applied according to the manufacturer's instructions, i.e., on an untreatedwood surface. However, the results revealed that wood panels treated with fire protection paint overacrylic paint only showed a relatively small deterioration compared to the panel treated according tothe manufacturer's instructions for the performed experiments. However, substantial differences emerged in the efficiency of the intumescent paint when panels treated with linseed oil paint where tested.The results indicate that even if the substrate is treated with a surface treatment, intumescent paint willstill provide a safety-enhancing effect.

Place, publisher, year, edition, pages
2024. , p. 63
Keywords [en]
intumescent paint, surface, finish, heat release rate
Keywords [sv]
brandskyddsfärg, ytskikt, ytbehandling, effektutveckling
National Category
Construction Management
Identifiers
URN: urn:nbn:se:ltu:diva-107862OAI: oai:DiVA.org:ltu-107862DiVA, id: diva2:1877483
External cooperation
Säkerhetspartner
Educational program
Fire Protection Engineer, bachelor's level
Supervisors
Examiners
Available from: 2024-07-19 Created: 2024-06-25 Last updated: 2026-03-12Bibliographically approved

Open Access in DiVA

fulltext(4687 kB)70 downloads
File information
File name FULLTEXT01.pdfFile size 4687 kBChecksum SHA-512
3465ca0abc83047321307efcc5d6b31b98da14949906342b25ba029ef7de083aeba259e67ed899fa4248fe89b8fd9afb2c83f5e0141cd204bff3981b23400625
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Norberg, ViktorRoslund, Fredrik
By organisation
Structural and Fire Engineering
Construction Management

Search outside of DiVA

GoogleGoogle Scholar
Total: 72 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 208 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf