A gestational age and birth weight assessment tool for frontline healthcare workers: Diagnostic Accuracy of Foot Length measurement for Identification of Preterm and Low Birth Weight in a Rural Setting of Sindh Province Pakistan
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Women's and Children's Health, International Child Health and Nutrition.ORCID iD: 0000-0001-8828-8325
2024 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Introduction: In Pakistan, 20% of neonates are born preterm or low birth weight (LBW), posing challenges to neonatal healthcare especially for those born in rural setting. Early identification of such babies is crucial for improved outcomes. 

Aim: This study aimed to evaluate the diagnostic accuracy of foot length (FL) measurement within 48 hours of birth with rigid plastic transparent ruler for the identification of preterm and LBW for frontline healthcare workers.  

Study I was a systematic review assessed the diagnostic accuracy of postnatal clinical scoring (PCS) methods and fetal length (FL) for identifying low birth weight (LBW) and preterm births in low- and middle-income countries (LMICs). This review included 45 studies. PCS methods had a precision of ±2.8 to ±3.2 weeks. FL <7.5 cm showed 64.0-98.9% sensitivity and 35.0-60.9% specificity for preterm birth, while FL <7.7 cm showed 58.0-84.7% sensitivity and 67.0-83.0% specificity for LBW. High heterogeneity (Higgins' I² >70%) was found and could be attributable to variations in settings, data collection, and lack of standardization in reference standards. 

Study II was a qualitative study which explored the knowledge, practices, and barriers which healthcare providers (HCPs) face while assessing gestational age (GA) and birth weight. Ten in-depth interviews revealed that HCPs preferred antenatal ultrasounds (A-US) for GA estimation due to its accuracy, despite challenges like workload, machine malfunctions, and cost. HCPs rarely used the Ballard score due to insufficient training and subjectivity. Electronic weighing scales were favoured for taking birth weight but had issues with calibration and batteries. Referral delays were caused by varying definitions of prematurity and LBW, limited resources, parent’s education, and negative parent experiences. HCPs found mobile apps useful for GA and birth weight calculation, but power failures and internet issues hindered their use.

Studies III and IV are test validation studies to test the diagnostic accuracy of FL measurement for identifying preterm and LBW newborns in rural Sindh, Pakistan, enrolling 336 newborns. The optimal FL cut-off for identifying pre-term newborns was ≤7.6 cm, with 90.8% sensitivity and 96.0% specificity, and LBW, the ≤7.6 cm cut-off showed 90.3% sensitivity and 81.8% specific-ity. 

Conclusion: FL measurement as a simple diagnostic tool for frontline healthcare workers to identify preterm and LBW newborns in rural areas aiding in triage, earlier intervention and, hence, improving neonatal outcomes.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2024. , p. 89
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, ISSN 1651-6206 ; 2062
Keywords [en]
preterm, LBW, gestational age, birth weight, postnatal clinical scoring, foot length, diagnostic accuracy, front-line healthcare workers, qualitative research
National Category
Medical and Health Sciences
Research subject
Medical Science; Epidemiology
Identifiers
URN: urn:nbn:se:uu:diva-532439ISBN: 978-91-513-2172-1 (print)OAI: oai:DiVA.org:uu-532439DiVA, id: diva2:1875737
Public defence
2024-09-12, Fåhræussalen, Rudbeck Laboratory, Dag Hammarskjölds väg 20, Uppsala, 13:15 (English)
Opponent
Supervisors
Note

Shiyam Sunder is inviting you to a scheduled Zoom meeting.

Topic: PhD Defense - Shiyam SunderTime: Sep 12, 2024 01:00 PM Amsterdam, Berlin, Rome, Stockholm, Vienna

Join Zoom Meetinghttps://uu-se.zoom.us/j/6911001600?omn=65425614650

Meeting ID: 691 100 1600Passcode: 12345One tap mobile+46844682488,,6911001600# Sweden+46850539728,,6911001600# Sweden

Dial by your location        +46 8 4468 2488 Sweden        +46 850 539 728 SwedenMeeting ID: 691 100 1600Find your local number: https://uu-se.zoom.us/u/czgUIMiFj

Join by SIP6911001600@109.105.112.2366911001600@109.105.112.235

Join by H.323109.105.112.236109.105.112.235Meeting ID: 691 100 1600Passcode: 12345

Available from: 2024-08-19 Created: 2024-06-24 Last updated: 2024-08-26
List of papers
1. Assessing Gestational Age and Birthweight of Newborns in Low- and Middle-Income Countries: Diagnostic Accuracy of Postnatal Clinical Scoring Methods and Foot Length – A Systematic Review and Meta-Analysis
Open this publication in new window or tab >>Assessing Gestational Age and Birthweight of Newborns in Low- and Middle-Income Countries: Diagnostic Accuracy of Postnatal Clinical Scoring Methods and Foot Length – A Systematic Review and Meta-Analysis
(English)Manuscript (preprint) (Other academic)
National Category
Medical and Health Sciences
Identifiers
urn:nbn:se:uu:diva-532436 (URN)
Available from: 2024-06-19 Created: 2024-06-19 Last updated: 2024-06-24
2. Exploring gestational age, and birth weight assessment in Thatta district, Sindh, Pakistan: Healthcare providers' knowledge, practices, perceived barriers, and the potential of a mobile app for identifying preterm and low birth weight
Open this publication in new window or tab >>Exploring gestational age, and birth weight assessment in Thatta district, Sindh, Pakistan: Healthcare providers' knowledge, practices, perceived barriers, and the potential of a mobile app for identifying preterm and low birth weight
Show others...
2024 (English)In: PLOS ONE, E-ISSN 1932-6203, Vol. 19, no 4, article id e0299395Article in journal (Refereed) Published
Abstract [en]

Introduction

Reliable methods for identifying prematurity and low birth weight (LBW) are crucial to ending preventable deaths in newborns. This study explored healthcare providers’ (HCPs) knowledge, practice, perceived barriers in assessing gestational age and birth weight and their referral methods for preterm and LBW infants. The study additionally assessed the potential of using a mobile app for the identification and referral decision of preterm and LBW.

Methods

This qualitative descriptive study was conducted in Thatta District, Sindh, Pakistan. Participants, including doctors, nurses, lady health visitors, and midwives, were purposefully selected from a district headquarter hospital, and private providers in the catchment area of Global Network’s Maternal and Newborn Health Registry (MNHR). Interviews were conducted using an interview guide after obtaining written informed consent. Audio recordings of the interviews were transcribed and analyzed using NVIVO® software with an inductive approach.

Results

The HCPs had extensive knowledge about antenatal and postnatal methods for assessing gestational age. They expressed a preference for antenatal ultrasound due to the perceived accuracy, though accept practical barriers including workload, machine malfunctions, and cost. Postnatal assessment using the Ballard score was only undertaken sparingly due to insufficient training and subjectivity. All HCPs preferred electronic weighing scales for birth weight Barriers encountered included weighing scale calibration and battery issues. There was variation in the definition of prematurity and LBW, leading to delays in referral. Limited resources, inadequate education, and negative parent past experiences were barriers to referral. Foot length measurements were not currently being used. While mobile apps are felt to have potential, unreliable electricity supply and internet connectivity are barriers.

Conclusion

The HCPs in this study were knowledgeable in terms of potential tools, but acknowledged the logistical and parental barriers to implementation.

Place, publisher, year, edition, pages
Public Library of Science (PLoS), 2024
National Category
Gynaecology, Obstetrics and Reproductive Medicine Pediatrics
Identifiers
urn:nbn:se:uu:diva-527319 (URN)10.1371/journal.pone.0299395 (DOI)001202890500005 ()38603767 (PubMedID)
Note

De två första författarna delar förstaförfattarskapet

De två sista författarna delar sistaförfattarskapet

Available from: 2024-04-27 Created: 2024-04-27 Last updated: 2025-02-11Bibliographically approved
3. Diagnostic accuracy of foot length measurement for identification of preterm newborn in rural Sindh, Pakistan
Open this publication in new window or tab >>Diagnostic accuracy of foot length measurement for identification of preterm newborn in rural Sindh, Pakistan
Show others...
2024 (English)In: BMJ Paediatrics Open, E-ISSN 2399-9772, Vol. 8, no 1, article id e002316Article in journal (Refereed) Published
Abstract [en]

Introduction Assessing gestational age accurately is crucial for saving preterm newborns. In low and middle-income countries, such as Pakistan, where access to antenatal ultrasonography (A-USG) is limited, alternative methods are needed. This study evaluated the diagnostic accuracy of foot length (FL) measurement for identifying preterm newborns in rural Pakistan using A-USG as the reference standard.

Methods A test validation study was conducted between January and June 2023 in rural Sindh, Pakistan, within the catchment area of the Global Network for Maternal Newborn Health Registry, Thatta. Singleton newborns whose mothers had an A-USG before 20 weeks of gestation were enrolled. A research assistant measured FL three times using a rigid transparent plastic ruler within 48 hours of birth and the average FL was reported. Sensitivity, specificity, positive and negative predictive values (PPV, NPV) and likelihood ratios were calculated. The optimal FL cut-off for the identification of preterm newborns was determined using the Youden Index.

Results A total of 336 newborns were included in the final analysis, of whom 75 (22.3%) were born before 37 weeks of gestation. The median gestational age of the newborns was 38.2 weeks, and the median FL was 7.9 cm. The area under the curve was 97.6%. The optimal FL cut-off for identifying preterm newborns was considered as ≤7.6 cm with a sensitivity of 90.8%, specificity of 96.0%, PPV of 86.7% and NPV of 97.3%. A lower cut-off of ≤7.5 cm had a sensitivity of 95.4%, specificity of 84.0%, PPV of 63.1% and NPV of 98.5%.

Conclusion In conclusion, this study highlights the utility of FL measurement for identifying preterm newborns in rural settings where A-USG is unavailable before 20 weeks of gestation. Optimal cut-offs of ≤7.6 and ≤7.5 cm provide a simple, cost-effective and reliable tool for clinicians and frontline healthcare providers in rural areas, respectively.

Place, publisher, year, edition, pages
BMJ Publishing Group Ltd, 2024
Keywords
Epidemiology, Neonatology
National Category
Public Health, Global Health and Social Medicine Pediatrics Gynaecology, Obstetrics and Reproductive Medicine
Identifiers
urn:nbn:se:uu:diva-527244 (URN)10.1136/bmjpo-2023-002316 (DOI)001173540000004 ()38267220 (PubMedID)
Available from: 2024-04-26 Created: 2024-04-26 Last updated: 2025-02-20Bibliographically approved
4. Postnatal Foot Length Measurement as a Proxy to Identify Low Birth Weight for Frontline Health Workers in Rural Sindh Province, Pakistan: A Diagnostic Accuracy Study
Open this publication in new window or tab >>Postnatal Foot Length Measurement as a Proxy to Identify Low Birth Weight for Frontline Health Workers in Rural Sindh Province, Pakistan: A Diagnostic Accuracy Study
Show others...
2024 (English)In: BMJ Open, E-ISSN 2044-6055, Vol. 14, article id e089153Article in journal (Refereed) Published
Abstract [en]

Objective: To assess the diagnostic accuracy of postnatal foot length (FL) measurements as a proxy to identify low birth weight (LBW) for frontline healthcare workers in rural Sindh Province, Pakistan.

Design: A community-based cross-sectional study.

Setting: This study was conducted in the catchment area of Global Network's Maternal and Newborn Health Registry, Thatta, Sindh Province, Pakistan, from January to June 2023.

Participants: Singleton live births irrespective of gestational age at birth.

Reference standard: Birth weight was measured using calibrated digital weighing scales in grams based on the average of three readings with minimal clothing.

Index test: FL was measured within 48 hours of birth using a rigid transparent plastic ruler in centimetres based on the average of three measurements.

Primary outcome: Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), receiver operating characteristics curve and area under the curve with 95% CI were calculated. Euclidean distance was used to identify the cutoff of FL to identify LBW. A simple linear equation was created to predict the birth weight.

Results: Out of 336 analysed newborns, 179 (53.3%) were male and 157 (46.7%) were female. The median birth weight was 2801 g (IQR: 2465-3057), of whom 88 (26.2%) were LBW. The median foot length was 7.9 cm (IQR: 7.6-8.1). For identifying LBW, the foot length cutoff was ≤ 7.6 cm with 90.3% sensitivity, 81.8% specificity, 63.8% PPV and 96.0% NPV. A FL of 7.6 cm predicted birth weight of 2459.4 g.

Conclusion: Postnatal FL cutoff of ≤ 7.6 cm has adequate predictive value served as a simple, low-cost and reliable method to identify LBW for frontline healthcare providers in the rural settings of Thatta without calibrated weighing scales to triage LBW newborns in need of higher-level care.

Place, publisher, year, edition, pages
BMJ Publishing Group Ltd, 2024
National Category
Pediatrics
Identifiers
urn:nbn:se:uu:diva-532438 (URN)10.1136/bmjopen-2024-089153 (DOI)001383680000001 ()39730154 (PubMedID)
Funder
Einhorn Foundation
Available from: 2024-06-19 Created: 2024-06-19 Last updated: 2025-01-13Bibliographically approved

Open Access in DiVA

UUThesis_Sunder,S-2024(1746 kB)905 downloads
File information
File name FULLTEXT02.pdfFile size 1746 kBChecksum SHA-512
7a39260c3bf31b530b29abbe9d62c7f93ae2df8fd1c7438494a492ba5d661ee046d0ba09019e92aac089e1823fd05fc008992f9a5d0c7c68aec247a82774c7dd
Type fulltextMimetype application/pdf
Errata(46 kB)42 downloads
File information
File name ERRATA01.pdfFile size 46 kBChecksum SHA-512
553fe2e950c8e7d06b4a68c99d6cb3e00e6f1ac9142030199c77ea4846374548cdd36df1e507918abf9244d2729617336f56c72a3e16117412cd724504d09fd6
Type errataMimetype application/pdf

Search in DiVA

By author/editor
Sunder, Shiyam
By organisation
International Child Health and Nutrition
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
Total: 908 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 898 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf