Digitala Vetenskapliga Arkivet

Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
A Study of Dynamic PET Frame-Binning on the Reference Logan Binding Potential
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.ORCID iD: 0000-0002-3353-6501
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Radiation Physics.
Umeå University, Faculty of Medicine, Department of Radiation Sciences, Diagnostic Radiology.ORCID iD: 0000-0001-5227-8117
Show others and affiliations
2017 (English)In: IEEE Transactions on Radiation and Plasma Medical Sciences, ISSN 2469-7311, Vol. 1, no 2, p. 128-135Article in journal (Refereed) Published
Abstract [en]

Objective: The reference Logan plot is a tool for determining the non-displaceable binding potential for dynamic PET exams using tracers with reversible bindings. Dynamic frame protocols affect noise in PET images and short frames can lead to quantitative uncertainties and noise-induced reconstruction bias. The aim of this study was to analyze the effect of frame binning on 11C-Raclopride striatal binding potential from reference Logan analysis. Methods: 12 healthy volunteers were scanned in list mode using 11C-raclopride, and the image data were reconstructed into 9 different frame binning schemes whereof 3 clinical schemes. Reconstruction was performed with 3 different algorithms, one based on filtered back projection (FBP) and two based on ordered subset expectation maximization (OSEM); one including resolution recovery. Logan plots were used for calculating the non-displaceable binding potential. Variation in binding potential was evaluated using Students t-tests. Results: It was found that frame lengths of up to 60 s gave significantly different results compared to the reference clinical protocol for OSEM, both with and without resolution recovery (maximum deviation: 10.3 % for the 15 s protocol). For FBP, frame lengths of up to 30 s gave significantly different results with a maximum deviation of 2.8 %. The higher sampling dependence of OSEM compared to FBP is likely due to noise-dependent bias in the OSEM algorithm, most apparent at high noise levels. Conclusions: Bias related to OSEM reconstruction of high-noise data is an important factor for dynamic PET protocols. Time frames of 120 s or more generate the most stable values for the striatum binding potential with the reference Logan plot for 11C-Raclopride brain PET.

Place, publisher, year, edition, pages
IEEE, 2017. Vol. 1, no 2, p. 128-135
Keywords [en]
¹¹C-Raclopride, binding potential, dynamic frame protocol, frame binning, Logan analysis, positron emission tomography, time sampling
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:umu:diva-146397DOI: 10.1109/TNS.2016.2639560ISI: 000456142100003Scopus ID: 2-s2.0-85113947023OAI: oai:DiVA.org:umu-146397DiVA, id: diva2:1196116
Available from: 2018-04-09 Created: 2018-04-09 Last updated: 2023-03-23Bibliographically approved
In thesis
1. Error reduction strategies for quantitative PET with focus on hybrid PET/MRI
Open this publication in new window or tab >>Error reduction strategies for quantitative PET with focus on hybrid PET/MRI
2022 (English)Doctoral thesis, comprehensive summary (Other academic)
Alternative title[sv]
Felreduktionsstrategier för kvantitativ PET med fokus på PET/MR hybridutrustning
Abstract [en]

Positron Emission Tomography (PET) is an important tool for detection, staging and follow-up in a wide range of diseases, including cancer and neurological disorders. As a functional imaging tool, PET can visualize biological processes, where positron emitting radioactive isotopes are connected to molecules with different functions in the body. While PET-images can be visually interpreted, they can also be used for quantitative measurements, where functions such as glucose metabolism, dopamine receptor function, and blood-flow can be quantified. Measurements can be performed in static imaging, or in dynamic imaging where graphical methods can be used for analysis.

PET images benefit from fusion with anatomical images which facilitates the interpretation. The combination of PET with computed tomography (CT) as in PET/CT hybrid equipment is a well-established imaging method. Magnetic Resonance Imaging (MRI) has some advantages over CT such as the high soft tissue contrast, but the combination with PET in a fully integrated system is far more technically challenging. Most of the technical concerns have been solved, and PET/MRI modalities are now commercially available.

Among the remaining challenges, the attenuation correction is still not yet completely solved, where the attenuation maps on the PET/MRI modalities are approximate and bone is not accounted for in all parts of the body. There are also challenges with quantitative PET in general, where for example low spatial resolution and presence of noise can lead to quantitative errors. The purpose of this thesis was to investigate and develop strategies to reduce quantitative errors in PET imaging with special focus on PET/MRI.

In study I, we studied the limits for quantification of size and uptake in small lesions in PET images reconstructed with a resolution modelling algorithm. We constructed a phantom of small balloons and reconstructed images with three different algorithms and measured volume and activity concentration in the images. The measured activity concentration in the lesions was corrected for the low resolution that yields partial-volume effects (PVE). We found that resolution modelling improved quantification of all lesions, and that in combination with correction factors, lesions larger than ~9 mm diameter could be correctly quantified.

Study II is focused on the effect of frame time length on the graphical Logan-analysis for dynamic studies with 11C-raclopride. Logan analysis is reported to be sensitive to noise, and image noise is heavily dependent on the frame time length. Noise can also generate bias when using iterative reconstruction methods. Weivconcluded that with region-based analyses, a bias of approximately 10% in the non-displaceable binding potential was found when using the shortest time frames, and that the bias was mainly caused by the reconstruction algorithm. Long time frames generated stable parameters.

The last two studies focused on the attenuation correction in PET/MRI hybrid equipment. In study III, a method for attenuation correction in PET/MRI was implemented and evaluated. The method is developed for the pelvic region and is based on statistical decomposition of T2-weighted images. We found that the new method improved quantification, especially in regions in vicinity of bone. In study IV, we proposed a concept for patient-specific quality assurance of attenuation maps, based on measurements of the MRI B0-field. The method shows potential to find errors in the attenuation map related to metallic implants, air, and patient contour.

The work in this thesis has contributed to increased knowledge about the effect of resolution and noise for quantification in PET images. It has also introduced a new method for attenuation correction in PET/MRI, and a concept for quality assurance of PET/MRI attenuation maps.

Place, publisher, year, edition, pages
Umeå: Umeå universitet, 2022. p. 58
Series
Umeå University medical dissertations, ISSN 0346-6612 ; 2175
Keywords
Positron emission tomography, PET, PET/MR, PET/MRI, medical imaging, partial-volume effect, attenuation correction
National Category
Radiology, Nuclear Medicine and Medical Imaging
Research subject
radiation physics
Identifiers
urn:nbn:se:umu:diva-194023 (URN)978-91-7855-762-2 (ISBN)978-91-7855-761-5 (ISBN)
Public defence
2022-05-20, Hörsal Betula, målpunkt L, Norrlands universitetssjukhus, Umeå, 09:00 (English)
Opponent
Supervisors
Funder
Swedish Cancer SocietyCancerforskningsfonden i NorrlandVästerbotten County Council
Available from: 2022-04-29 Created: 2022-04-22 Last updated: 2022-04-27Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Search in DiVA

By author/editor
Wallstén, ElinAxelsson, JanKarlsson, MikaelRiklund, KatrineLarsson, Anne
By organisation
Radiation PhysicsDiagnostic Radiology
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 592 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf