Digitala Vetenskapliga Arkivet

Driftinformation
Ett driftavbrott i samband med versionsuppdatering är planerat till 17/11-2026, kl 12.00-14.00. Under den tidsperioden kommer DiVA inte att vara tillgängligt.
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Factors influencing high quality low voltage TEM imaging of biological routinely stained specimen
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Matematisk-datavetenskapliga sektionen, Institutionen för informationsteknologi, Avdelningen för visuell information och interaktion. Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Matematisk-datavetenskapliga sektionen, Institutionen för informationsteknologi, Bildanalys och människa-datorinteraktion.
Vironova AB.
Vironova AB.
Delong Instruments.
Visa övriga samt affilieringar
2013 (Engelska)Ingår i: Proceedings, part I / [ed] Reinhard Rachel, 2013, s. 321-322Konferensbidrag, Poster (med eller utan abstract) (Övrig (populärvetenskap, debatt, mm))
Abstract [en]

     Low-voltage TEM imaging requires sufficient electron transmittance. One advantage of low-voltage TEM is the increased electron scattering resulting in higher contrast. Principally this implies that negative stain contrast agents may not be needed which would be beneficial since they inherently reduce the electron transmittance. However, negative stains are not only used to increase the contrast when imaging biological specimens. They also help in fixation and protect the specimen from dehydration. Hence, a requirement to acquire high quality images of biological specimen using a low-voltage TEM is fixation/staining while maintaining enough electron transmittance. This identifies and a few factors that can be investigated in order to acquire images of biological specimens using low-voltage TEM: supporting film, choice (molecular weight) of stain and thickness of stain layer. Here we have focused on the first factor, the supporting film. More specifically, we have focused on the thickness of amorphous carbon films since such supports tend to have negligible influence of the specimen, and the negative stains generally distribute evenly (which to our experience is not the case when using very thin graphene grids).

     We here present a small study where the influence of the thickness of the carbon supporting film on electron transmittance has been investigated. The electron transmittance for two thicknesses of carbon films (EMS grids >30 nm and KC S6 grids <10 nm) has been measured at a range of energies, from 5 keV to 100 keV in an LVEM 5 (5keV), and a Tecnai Spirit BioTwin (20 to 100keV).  The transmittance was derived as the ratio of the mean intensity values of images acquired with and without the grids inserted into the electron beam. How the transmittance for the two carbon film thicknesses varies for different electron voltages is shown in Figure 1.

     To illustrate how the final low-voltage TEM image quality is influenced by the carbon film thickness, thick and thin carbon film grids containing BK virus-like particles stained with 2% UAc were prepared and imaged at 20 keV in a Tecnai Spirit BioTwin microscope at magnifications ranging from 6000 to 87000. Example images of the EMS and KS C6 grids are shown in Figure 2 together with their corresponding histograms.

     In conclusion: reducing the carbon layer thickness from ~30 nm to <10 nm results in a significant increase in electron transmittance showing the following benefits:

 

–         Improved image quality

–         Reduced risk for dehydration effects

–         Rapid and reproducible preparation procedures

–         Conventional nsTEM procedures can be utilized

–         Reduced chromatic aberration originating from the non-elastic scattering of the incident beam in the sample

 

This work was carried out jointly by the Centre for Image Analysis at Uppsala University and Swedish University of Agricultural Sciences, Vironova AB, and Delong Instruments, as part of the Eurostars miniTEM project, in which a low-voltage TEM with built in automated acquisition and analysis functionally is being developed.

Ort, förlag, år, upplaga, sidor
2013. s. 321-322
Nyckelord [en]
electron transmittance, carbon film thickness, image intensity
Nationell ämneskategori
Annan data- och informationsvetenskap
Forskningsämne
Datoriserad bildanalys; Datoriserad bildbehandling
Identifikatorer
URN: urn:nbn:se:uu:diva-212520OAI: oai:DiVA.org:uu-212520DiVA, id: diva2:678193
Konferens
Microscopy Conference (MC) 2013
Tillgänglig från: 2013-12-11 Skapad: 2013-12-11 Senast uppdaterad: 2022-01-28

Open Access i DiVA

Fulltext saknas i DiVA

Sök vidare i DiVA

Av författaren/redaktören
Sintorn, Ida-Maria
Av organisationen
Avdelningen för visuell information och interaktionBildanalys och människa-datorinteraktion
Annan data- och informationsvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 946 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf