Round robin study to evaluate the reconstructed human epidermis (RhE) model as an in vitro skin irritation test for detection of irritant activity in medical device extracts
RIVM National Institute for Public Health and the Environment, The Netherlands.
Seh consulting + services, Germany.
Nelson Laboratories Inc., USA.
MatVitro Life Science Laboratories, Slovakia.
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: Toxicology in Vitro, ISSN 0887-2333, E-ISSN 1879-3177, Vol. 50, s. 439-449Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Assessment of skin irritation is an essential component of the safety evaluation of medical devices. OECD Test Guideline 439 describes the use of reconstructed human epidermis (RhE) as an in vitro test system for classification of skin irritation by neat chemicals. An international round robin study was conducted to evaluate the RhE method for determination of skin irritant potential of medical device extracts. Four irritant polymers and three non-irritant controls were obtained or developed that had demonstrated their suitability to act as positive or negative test samples. The RhE tissues (EpiDerm™ and SkinEthic™ RHE) were dosed with 100 μL aliquots of either saline or sesame oil extract. Incubation times were 18 h (EpiDerm™) and 24 h (SkinEthic™ RHE). Cell viability reduction > 50% was indicative of skin irritation. Both the EpiDerm™ and SkinEthic™ RHE tissues were able to correctly identify virtually all of the irritant polymer samples either in the saline, sesame oil or both solvent extracts. Our results indicate that RhE tissue models can detect the presence of strong skin irritants at low levels in dilute medical device polymer extracts. Therefore, these models may be suitable replacements for the rabbit skin irritation test to support the biological evaluation of medical devices.

Ort, förlag, år, upplaga, sidor
2018. Vol. 50, s. 439-449
Nyckelord [en]
Alternative testing, In vitro, Irritation, Medical devices, Reconstructed human epidermis
Nationell ämneskategori
Naturvetenskap
Identifikatorer
URN: urn:nbn:se:ri:diva-33262DOI: 10.1016/j.tiv.2018.01.001Scopus ID: 2-s2.0-85040654993OAI: oai:DiVA.org:ri-33262DiVA, id: diva2:1182146
Tillgänglig från: 2018-02-12 Skapad: 2018-02-12 Senast uppdaterad: 2025-09-23Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Fant, Kristina
Av organisationen
Kemi och material
I samma tidskrift
Toxicology in Vitro
Naturvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 142 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf