Digitala Vetenskapliga Arkivet

Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Improving accuracy of in situ gamma-ray spectrometry
Umeå universitet, Medicinsk fakultet, Strålningsvetenskaper, Radiofysik.
2008 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Gamma-ray spectrometry measurements performed on site, or “in situ”, is a widely used and powerful method that can be employed both to identify and quantify ground deposited radionuclides. The purpose of this thesis is to improve the calibration of high purity germanium (HPGe) detectors for in situ measurements, and calculate the combined uncertainty and potential systematic effects.

An improved semi-empirical calibration method is presented, based on a novel expression for the intrinsic detector efficiency that includes both the energy and angular response of the detector. A three-layer model for the description of the depth distribution of the radionuclide and the soil density is proposed. The combined uncertainty of intrinsic detector efficiency calibrations and in situ measurements according to the proposed method was estimated. The uncertainty in the intrinsic detector efficiency was found to be 5.1 and 8.1% (coverage factor k=1, i.e. for a confidence interval of about 68%), for the two detectors calibrated. These numbers were, however, at a later stage reduced to 3.7 and 4.2%, using a revised expression for the intrinsic detector efficiency.

For in situ measurements, the combined standard uncertainty was found to be 15-20% (k=1), based on the original expression for the intrinsic detector efficiency. Monte Carlo models of the two detectors were created and Monte Carlo calculated values for intrinsic detector efficiency were compared with experimental data. As a discrepancy was found, a thorough investigation of the detector response was performed. Scanning of the detector surface with a collimated 59.5 keV photon beam revealed the detector response to be highly irregular over the detector surface. It was concluded that the efficiency deficit of the detector could most likely be attributed to an increase in dead layer thickness compared with manufacturer supplied data. The thickness of the dead layer was estimated to be 1.5-1.9 mm, whereas the nominal value was 0.7 mm. Radiographs of the detectors were produced that provided valuable information about the physical dimensions of the germanium crystal, as well as its actual location within the detector housing.

The Monte Carlo models were employed to calculate in situ measurement efficiencies for measurements of 137Cs deposition from the Chernobyl fallout. Results from the Monte Carlo simulations were compared both with the semi-empirical method and with soil sample data, and satisfactory agreement was confirmed. It was then proceeded to employ the Monte Carlo model to calculate the effect on in situ measurement results by two influencing parameters: ground curvature and activity in trees. Neither of these parameters was found to influence the result by more than about 25%. This deviation is comparable with the measurement uncertainty, and should not deter from measurements in such terrain.

Ort, förlag, år, upplaga, sidor
Umeå: Radiofysik , 2008. , s. 47
Serie
Umeå University medical dissertations, ISSN 0346-6612 ; 1201
Nyckelord [en]
gamma-ray spectrometry, in situ measurement, HPGe detector, 137Cs, Monte Carlo, efficiency calibration, measurement uncertainty
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:umu:diva-1805ISBN: 978-91-7264-621-6 (tryckt)OAI: oai:DiVA.org:umu-1805DiVA, id: diva2:142038
Disputation
2008-09-19, sal 244, by 7, NUS, Umeå, 09:00 (Engelska)
Opponent
Tillgänglig från: 2008-09-03 Skapad: 2008-09-03 Senast uppdaterad: 2010-01-22Bibliografiskt granskad
Delarbeten
1. In situ gamma-ray spectrometry for environmental monitoring: a semi empirical calibration method.
Öppna denna publikation i ny flik eller fönster >>In situ gamma-ray spectrometry for environmental monitoring: a semi empirical calibration method.
Visa övriga...
2006 (Engelska)Ingår i: Radiation Protection Dosimetry, ISSN 0144-8420, Vol. 121, nr 3, s. 310-316Artikel i tidskrift (Refereegranskat) Published
Identifikatorer
urn:nbn:se:umu:diva-16618 (URN)doi:10.1093/rpd/ncl041 (DOI)16632586 (PubMedID)2-s2.0-33846051814 (Scopus ID)
Tillgänglig från: 2007-02-23 Skapad: 2007-02-23 Senast uppdaterad: 2023-03-24Bibliografiskt granskad
2. A detailed investigation of HPGe detector response for improved Monte Carlo efficiency calculations
Öppna denna publikation i ny flik eller fönster >>A detailed investigation of HPGe detector response for improved Monte Carlo efficiency calculations
2008 (Engelska)Ingår i: Nuclear instruments and methods in physics research A, ISSN 0168-9002, Vol. 587, nr 2/3, s. 304-314Artikel i tidskrift (Refereegranskat) Published
Identifikatorer
urn:nbn:se:umu:diva-3366 (URN)
Tillgänglig från: 2008-09-03 Skapad: 2008-09-03Bibliografiskt granskad
3. Uncertainty in HPGe detector calibrations for in situ gamma-ray spectrometry
Öppna denna publikation i ny flik eller fönster >>Uncertainty in HPGe detector calibrations for in situ gamma-ray spectrometry
2009 (Engelska)Ingår i: Radiation Protection Dosimetry, ISSN 0144-8420, E-ISSN 1742-3406, Vol. 134, nr 2, s. 122-129Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Semi-empirical methods are often used for efficiency calibrations of in situ gamma-ray spectrometry measurements with high-purity germanium detectors. The intrinsic detector efficiency is experimentally determined for different photon energies and angles of incidence, and a suitable expression for the efficiency is fitted to empirical data. In this work, the combined standard uncertainty of such an efficiency function for two detectors was assessed. The uncertainties in individual efficiency measurements were found to be about 1.9 and 3.1% (with a coverage factor k = 1, i.e. with a confidence interval of about 68%) for the two detectors. The main contributions to these uncertainties were found to originate from uncertainties in source-to-detector distance, source activity and full-energy peak count rate. The standard uncertainties of the fitted functions were found to be somewhat higher than the uncertainty of individual data points, i.e. 5.2 and 8.1% (k = 1). With the introduction of a new expression for the detector efficiency, these uncertainties were reduced to 3.7 and 4.2%, i.e. with up to a factor of two. Note that this work only addresses the uncertainty in the determination of intrinsic detector efficiency.

Ort, förlag, år, upplaga, sidor
Oxford University Press, 2009
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
urn:nbn:se:umu:diva-23549 (URN)10.1093/rpd/ncp079 (DOI)19429646 (PubMedID)2-s2.0-66449120251 (Scopus ID)
Tillgänglig från: 2009-06-24 Skapad: 2009-06-24 Senast uppdaterad: 2023-03-23Bibliografiskt granskad
4. Evaluation of Monte Carlo-based calibrations of HPGe detectors for in situ gamma-ray spectrometry
Öppna denna publikation i ny flik eller fönster >>Evaluation of Monte Carlo-based calibrations of HPGe detectors for in situ gamma-ray spectrometry
Visa övriga...
2009 (Engelska)Ingår i: Journal of Environmental Radioactivity, ISSN 0265-931X, E-ISSN 1879-1700, Vol. 100, nr 11, s. 935-940Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The aim of this work was to evaluate the use of Monte Carlo-based calibrations for in situ gamma-ray spectrometry. We have performed in situ measurements at five different sites in Sweden using HPGe detectors to determine ground deposition activity levels of (137)Cs from the 1986 Chernobyl accident. Monte Carlo-calculated efficiency calibration factors were compared with corresponding values calculated using a more traditional semi-empirical method. In addition, results for the activity ground deposition were also compared with activity densities found in soil samples. In order to facilitate meaningful comparisons between the different types of results, the combined standard uncertainty of in situ measurements was assessed for both calibration methods. Good agreement, both between the two calibration methods, and between in situ measurements and soil samples, was found at all five sites. Uncertainties in in situ measurements for the given measurement conditions, about 20 years after the fallout occurred, were found to be in the range 15-20% (with a coverage factor k=1, i.e. with a confidence interval of about 68%).

Nyckelord
Germanium detector, HPGe, uncertainty, gamma spectrometry, in situ measurements, Monte Carlo, GUM
Nationell ämneskategori
Fysik
Identifikatorer
urn:nbn:se:umu:diva-26103 (URN)10.1016/j.jenvrad.2009.06.006 (DOI)19604609 (PubMedID)2-s2.0-69849110505 (Scopus ID)
Tillgänglig från: 2009-09-24 Skapad: 2009-09-24 Senast uppdaterad: 2023-03-23Bibliografiskt granskad
5. In situ gamma-ray spectrometry: influence of ground curvature and activity in trees
Öppna denna publikation i ny flik eller fönster >>In situ gamma-ray spectrometry: influence of ground curvature and activity in trees
Visa övriga...
(Engelska)Manuskript (Övrigt vetenskapligt)
Identifikatorer
urn:nbn:se:umu:diva-3369 (URN)
Tillgänglig från: 2008-09-03 Skapad: 2008-09-03 Senast uppdaterad: 2010-01-13Bibliografiskt granskad

Open Access i DiVA

fulltext(804 kB)5038 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 804 kBChecksumma MD5
80df3986dd7b9f50345447eee988a3e1710f374ea433a2c6ef1d39477a7d700de67ee96a
Typ fulltextMimetyp application/pdf

Av organisationen
Radiofysik
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 5054 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
Totalt: 1859 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf