Digitala Vetenskapliga Arkivet

Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Effect of formation depth on the performance of high-temperature aquifer thermal energy storage (HT-ATES)
Chengdu Univ Technol, Coll Energy, Chengdu 610059, Peoples R China;.
Chengdu Univ Technol, Coll Energy, Chengdu 610059, Peoples R China;;Chengdu Univ Technol, State Key Lab Oil & Gas Reservoir Geol & Exploitat, Chengdu 610059, Peoples R China;;Tianfu Yongxing Lab, Chengdu 610213, Peoples R China;.
Tianfu Yongxing Lab, Chengdu 610213, Peoples R China;.
Chengdu Univ Technol, Coll Energy, Chengdu 610059, Peoples R China;;Chengdu Univ Technol, State Key Lab Oil & Gas Reservoir Geol & Exploitat, Chengdu 610059, Peoples R China;;Tianfu Yongxing Lab, Chengdu 610213, Peoples R China;.
Vise andre og tillknytning
2026 (engelsk)Inngår i: Journal of Renewable and Sustainable Energy, E-ISSN 1941-7012, Vol. 18, nr 4, artikkel-id 043901Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

High-temperature aquifer thermal energy storage (HT-ATES) is regarded as a promising technology for mitigating the mismatch between renewable energy supply and demand, and its performance is strongly governed by formation depth. This study employed three-dimensional thermo-hydro-mechanical coupled simulation and spatial moment quantification to examine depth (600-1400 m) effects on a conventional doublet HT-ATES system. The results show that formation depth significantly affected the extent of energy dispersion: the horizontal dispersion range of thermal and cold plumes at 1400 m was 3.5%-4.0% greater than that at 600 m, with vertical dispersion constrained by thickness. The injection/production pressure difference decreased with formation depth and gradually converged after long-term cycling. The production temperature exhibited the characteristic that deep formations provided superior heat storage capacity, whereas shallow formations demonstrated better cold storage performance. The influence of formation depth on cold well temperature was markedly stronger than that on the hot well, and this disparity intensified progressively with increasing depth. Energy recovery efficiency increased with cycling but decreased with depth, with depth-dependent gaps narrowing. Depth governed system operation via fluid properties, providing a quantitative basis for HT-ATES depth selection, optimization, and long-term stability.

sted, utgiver, år, opplag, sider
American Institute of Physics (AIP), 2026. Vol. 18, nr 4, artikkel-id 043901
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-596115DOI: 10.1063/5.0325626ISI: 001837884200001Scopus ID: 2-s2.0-105046726073OAI: oai:DiVA.org:uu-596115DiVA, id: diva2:2094124
Tilgjengelig fra: 2026-08-21 Laget: 2026-08-21 Sist oppdatert: 2026-08-21bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Søk i DiVA

Av forfatter/redaktør
Jiang, Chuanyin
Av organisasjonen
I samme tidsskrift
Journal of Renewable and Sustainable Energy

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 14 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf