Digitala Vetenskapliga Arkivet

Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Biomechanical Strategies for Minimizing Force Plate Targeting Effects during Running: Efficacy of Masked Force Plate Integration with Augmented Visual Feedback
Ningbo Univ, Fac Sports Sci, Ningbo, Peoples R China.
Ningbo Univ, Fac Sports Sci, Ningbo, Peoples R China; Ningbo 2 Hosp, Zhejiang Engn Res Ctr New Technol & Applicat Heliu, Ningbo, Peoples R China.
Ningbo Univ, Fac Sports Sci, Ningbo, Peoples R China.
Ningbo Univ, Fac Sports Sci, Ningbo, Peoples R China.
Vise andre og tillknytning
2026 (engelsk)Inngår i: Journal of Human Kinetics, ISSN 1640-5544, E-ISSN 1899-7562, Vol. 102, s. 5-21Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This study aimed to investigate the targeting effect on the gait induced by the visual presence of a force plate during running and to develop a step guidance strategy (SGS) to minimize this effect and improve data acquisition success. Thirty-two healthy male participants were tested under three conditions: when the force plate was masked (MASK), when it was masked with the SGS implemented, and when it was visible (UNMASK). Kinematic, kinetic, and surface electromyography (sEMG) data were collected. The success rates for data acquisition were 30% for the MASK, 65.75% for the UNMASK, and 84.21% for the SGS condition. The UNMASK condition resulted in increased stride time, decreased stance time, and a lower coefficient of variation (CV) for the heel-to-force-plate distance. This condition also showed temporal variations in joint angles, an increased CV of the ankle joint angle waveform, significant alterations in ground reaction forces (GRF)-including greater peak braking force and impulses-and increased activation of the Vastus Medialis. The findings conclude that the visual presence of a force plate induces a targeting effect that undermines result reliability, and the proposed SGS effectively reduces this effect while significantly improving the success rate of data acquisition.

sted, utgiver, år, opplag, sider
Termedia Sp. z.o.o. , 2026. Vol. 102, s. 5-21
Emneord [en]
gait analysis, targeting effect, step guidance strategy, joint kinematics, GRF, sEMG
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-386291DOI: 10.5114/jhk/212382ISI: 001783702600001PubMedID: 42211801Scopus ID: 2-s2.0-105038038824OAI: oai:DiVA.org:kth-386291DiVA, id: diva2:2088854
Merknad

QC 20260730

Tilgjengelig fra: 2026-07-30 Laget: 2026-07-30 Sist oppdatert: 2026-07-30bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Søk i DiVA

Av forfatter/redaktør
Xiang, Liangliang
Av organisasjonen
I samme tidsskrift
Journal of Human Kinetics

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 11 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf