Endre søk
Begrens søket
123456 1 - 50 of 282
RefereraExporteraLink til resultatlisten
Permanent link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Treff pr side
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sortering
  • Standard (Relevans)
  • Forfatter A-Ø
  • Forfatter Ø-A
  • Tittel A-Ø
  • Tittel Ø-A
  • Type publikasjon A-Ø
  • Type publikasjon Ø-A
  • Eldste først
  • Nyeste først
  • Skapad (Eldste først)
  • Skapad (Nyeste først)
  • Senast uppdaterad (Eldste først)
  • Senast uppdaterad (Nyeste først)
  • Standard (Relevans)
  • Forfatter A-Ø
  • Forfatter Ø-A
  • Tittel A-Ø
  • Tittel Ø-A
  • Type publikasjon A-Ø
  • Type publikasjon Ø-A
  • Eldste først
  • Nyeste først
  • Skapad (Eldste først)
  • Skapad (Nyeste først)
  • Senast uppdaterad (Eldste først)
  • Senast uppdaterad (Nyeste først)
Merk
Maxantalet träffar du kan exportera från sökgränssnittet är 250. Vid större uttag använd dig av utsökningar.
  • 1.
    Aarstad, Olav
    et al.
    NTNU Norwegian University of Science and Technology, Norway.
    Heggset, Ellinor B.
    RISE - Research Institutes of Sweden, Bioekonomi, PFI.
    Pedersen, Ina Sander
    NTNU Norwegian University of Science and Technology, Norway.
    Björnöy, Sindre H.
    NOBIPOL,NTNU Norwegian University of Science and Technology, Norway.
    Syverud, Kristin
    RISE - Research Institutes of Sweden, Bioekonomi, PFI.
    Strand, Berit L.
    NTNU Norwegian University of Science and Technology, Norway.
    Mechanical properties of composite hydrogels of alginate and cellulose nanofibrils2017Inngår i: Polymers, ISSN 2073-4360, E-ISSN 2073-4360, Vol. 9, nr 8, 378Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Alginate and cellulose nanofibrils (CNF) are attractive materials for tissue engineering and regenerative medicine. CNF gels are generally weaker and more brittle than alginate gels, while alginate gels are elastic and have high rupture strength. Alginate properties depend on their guluronan and mannuronan content and their sequence pattern and molecular weight. Likewise, CNF exists in various qualities with properties depending on, e.g., morphology and charge density. In this study combinations of three types of alginate with different composition and two types of CNF with different charge and degree of fibrillation have been studied. Assessments of the composite gels revealed that attractive properties like high rupture strength, high compressibility, high gel rigidity at small deformations (Young’s modulus), and low syneresis was obtained compared to the pure gels. The effects varied with relative amounts of CNF and alginate, alginate type, and CNF quality. The largest effects were obtained by combining oxidized CNF with the alginates. Hence, by combining the two biopolymers in composite gels, it is possible to tune the rupture strength, Young’s modulus, syneresis, as well as stability in physiological saline solution, which are all important properties for the use as scaffolds in tissue engineering.

  • 2.
    Addi, Simon
    et al.
    Umeå universitet, Medicinsk fakultet, Odontologi, Odontologisk materialvetenskap.
    Hedayati-Khams, Arjang
    Umeå universitet, Medicinsk fakultet, Odontologi, Odontologisk materialvetenskap.
    Poya, Amin
    Umeå universitet, Medicinsk fakultet, Odontologi, Odontologisk materialvetenskap.
    Sjögren, Göran
    Umeå universitet, Medicinsk fakultet, Odontologi, Odontologisk materialvetenskap.
    Interface gap size of manually and CAD/CAM-manufactured ceramic inlays/onlays in vitro.2002Inngår i: Journal of Dentistry, ISSN 0300-5712, Vol. 30, nr 1, 53-58 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Objectives : To determine the fit of ceramic inlays manufactured using a recently introduced CAD/CAM-system (Decim) and of two types of laboratory-made heat-pressed ceramics (IPS Empress and Opc).

    Materials and methods : Extracted human premolars were prepared to receive mesio-occlusodistal (MOD) ceramic inlays, for which 10 Denzir, 10 IPS Empress, and 10 Opc were fabricated. The Denzir restorations were produced by the manufacturer of the CAD/CAM-system, and the IPS Empress and Opc by student dental technicians. Before luting the internal fit on the diestone models and on the premolars was determined using replicas. After luting on the premolars with a resin composite the marginal and internal fit were measured. The values were analyzed statistically using ANOVA and Scheffe's test at a significance level of p<0.05.

    Results : Before luting there were no significant differences ( p>0.05) in the internal gap width between the three systems studied when placed on their matching diestone models. When placed on the premolars a significant difference ( p<0.01) in the internal fit was seen between Empress and Opc before luting, whereas there were no significant differences ( p>0.05) between Empress and Denzir and between Opc and Denzir. Between the diestone models and the premolars there were significant differences ( p<0.01) in the internal fit, except for IPS Empress. After luting there were no significant differences ( p>0.05) between IPS Empress and Denzir, whereas the marginal gap width was significantly wider ( p<0.001) for Opc than for IPS Empress and Denzir. The internal fit was significantly ( p<0.001) wider for Opc than for IPS Empress, whereas there were no significant differences ( p>0.05) between IPS Empress and Denzir or between Opc and Denzir.

    Conclusion : After luting there were only slight differences in the fit between the restorations fabricated using the three different manufacturing techniques and ceramics. Therefore, long-term follow-up studies are needed to assess the clinical significance of the slight differences between the three systems.

  • 3.
    Ajalloueian, Fatemeh
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Kemiska sektionen, Institutionen för kemi - Ångström, Polymerkemi. Uppsala universitet, Science for Life Laboratory, SciLifeLab.
    Zeiai, Said
    Fossum, Magdalena
    Hilborn, Jöns G.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Kemiska sektionen, Institutionen för kemi - Ångström, Polymerkemi. Uppsala universitet, Science for Life Laboratory, SciLifeLab.
    Constructs of electrospun PLGA, compressed collagen and minced urothelium for minimally manipulated autologous bladder tissue expansion2014Inngår i: Biomaterials, ISSN 0142-9612, E-ISSN 1878-5905, Vol. 35, nr 22, 5741-5748 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Bladder regeneration based on minced bladder mucosa in vivo expansion is an alternative to in vitro culturing of urothelial cells. Here, we present the design of a hybrid, electrospun poly(lactic-co-glycolide) (PLGA) - plastically compressed (PC) collagen scaffold that could allow in vivo bladder mucosa expansion. Optimisation of electrospinning was performed in order to obtain increased pore sizes and porosity to consolidate the construct and to support neovascularisation and tissue ingrowth. Tensile tests showed an increase in average tensile strength from 0.6 MPa for PC collagen to 3.57 MPa for the hybrid construct. The optimised PLGA support scaffold was placed between two collagen gels, and the minced tissue was distributed either on top or both on top and inside the construct prior to PC; this was then cultured for up to four weeks. Morphology, histology and SEM demonstrated that the construct maintained its integrity throughout cell culture. Cells from minced tissue migrated, expanded and re-organised to a confluent cell layer on the top of the construct after two weeks and formed a multilayered urothelium after four weeks. Cell morphology and phenotype was typical for urothelial mucosa during tissue culture. (C) 2014 Elsevier Ltd. All rights reserved.

  • 4.
    Ajaxon, Ingrid
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Can Bone Void Fillers Carry Load?: Behaviour of Calcium Phosphate Cements Under Different Loading Scenarios2017Doktoravhandling, med artikler (Annet vitenskapelig)
    Abstract [en]

    Calcium phosphate cements (CPCs) are used as bone void fillers and as complements to hardware in fracture fixation. The aim of this thesis was to investigate the possibilities and limitations of the CPCs’ mechanical properties, and find out if these ceramic bone cements can carry application-specific loads, alone or as part of a construct. Recently developed experimental brushite and apatite cements were found to have a significantly higher strength in compression, tension and flexion compared to the commercially available CPCs chronOS™ Inject and Norian® SRS®. By using a high-resolution measurement technique the elastic moduli of the CPCs were determined and found to be at least twice as high compared to earlier measurements, and closer to cortical bone than trabecular bone. Using the same method, Poisson's ratio for pure CPCs was determined for the first time. A non-destructive porosity measurement method for wet brushite cements was developed, and subsequently used to study the porosity increase during in vitro degradation. The compressive strength of the experimental brushite cement was still higher than that of trabecular bone after 25 weeks of degradation, showing that the cement can carry high loads over a time span sufficiently long for a fracture to heal. This thesis also presents the first ever fatigue results for acidic CPCs, and confirms the importance of testing the materials under cyclic loading as the cements may fail at stress levels much lower than the material’s quasi-static compressive strength. A decrease in fatigue life was found for brushite cements containing higher amounts of monetite. Increasing porosity and testing in a physiological buffer solution (PBS), rather than air, also decreased the fatigue life. However, the experimental brushite cement had a high probability of surviving loads found in the spine when tested in PBS, which has previously never been accomplished for acidic CPCs. In conclusion, available brushite cements may be able to carry the load alone in scenarios where the cortical shell is intact, the loading is mainly compressive, and the expected maximum stress is below 10 MPa. Under such circumstances this CPC may be the preferred choice over less biocompatible and non-degradable materials.

  • 5.
    Ajaxon, Ingrid
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Acciaioli, Alice
    Istituto Ortopedico Rizzoli, Laboratorio di Tecnologia Medica.
    Lionello, Giacomo
    Istituto Ortopedico Rizzoli, Laboratorio di Tecnologia Medica.
    Ginebra, Maria-Pau
    Biomaterials, Biomechanics and Tissue Engineering Group, Dept. of Materials Science and Metallurgy, Technical University of Catalonia (UPC).
    Öhman, Caroline
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Baleani, Massimilliano
    Istituto Ortopedico Rizzoli, Laboratorio di Tecnologia Medica.
    Persson, Cecilia
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Elastic properties and strain-to-crack-initation of calcium phosphate bone cements: revelations of a high-resolution measurement technique2017Inngår i: Journal of The Mechanical Behavior of Biomedical Materials, ISSN 1751-6161, E-ISSN 1878-0180, Vol. 74, 428-437 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Calcium phosphate cements (CPCs) should ideally have mechanical properties similar to those of the bone tissue the material is used to replace or repair. Usually, the compressive strength of the CPCs is reported and, more rarely, the elastic modulus. Conversely, scarce or no data are available on Poisson's ratio and strain-to-crack-initiation. This is unfortunate, as data on the elastic response is key to, e.g., numerical model accuracy. In this study, the compressive behaviour of brushite, monetite and apatite cements was fully characterised. Measurement of the surface strains was done using a digital image correlation (DIC) technique, and compared to results obtained with the commonly used built-in displacement measurement of the materials testers. The collected data showed that the use of fixed compression platens, as opposed to spherically seated ones, may in some cases underestimate the compressive strength by up to 40%. Also, the built-in measurements may underestimate the elastic modulus by up to 62% as compared to DIC measurements. Using DIC, the brushite cement was found to be much stiffer (24.3 ± 2.3 GPa) than the apatite (13.5 ± 1.6 GPa) and monetite (7.1 ± 1.0 GPa) cements, and elastic moduli were inversely related to the porosity of the materials. Poisson's ratio was determined to be 0.26 ± 0.02 for brushite, 0.21 ± 0.02 for apatite and 0.20 ± 0.03 for monetite. All investigated CPCs showed low strain-to-crack-initiation (0.17–0.19%). In summary, the elastic modulus of CPCs is substantially higher than previously reported and it is concluded that an accurate procedure is a prerequisite in order to properly compare the mechanical properties of different CPC formulations. It is recommended to use spherically seated platens and measuring the strain at a relevant resolution and on the specimen surface.

  • 6.
    Ajaxon, Ingrid
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Acciaioli, Alice
    Lionello, Giacomo
    Ginebra, Maria-Pau
    Öhman, Caroline
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Persson, Cecilia
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Baleani, Massimiliano
    Compressive strength increase of calcium phosphate bone cements is accompanied by a stiffness increase2016Konferansepaper (Annet vitenskapelig)
  • 7.
    Ajaxon, Ingrid
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Holmberg, Anders
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Öhman Mägi, Caroline
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Persson, Cecilia
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    The influence of porosity on the fatigue properties of brushite cement2016Inngår i: Biomaterials for tissue engineering models, 2016Konferansepaper (Annet vitenskapelig)
  • 8.
    Ajaxon, Ingrid
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Holmberg, Anders
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Öhman-Mägi, Caroline
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Persson, Cecilia
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Compressive fatigue properties of a high-strength, degradable calcium phosphate bone cement – influence of porosity and environmentManuskript (preprint) (Annet vitenskapelig)
  • 9.
    Ajaxon, Ingrid
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Maazouz, Yassine
    Ginebra, Maria-Pau
    Öhman, Caroline
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Persson, Cecilia
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Evaluation of a porosity measurement method for wet calcium phosphate cements2015Inngår i: Journal of biomaterials applications, ISSN 0885-3282, E-ISSN 1530-8022, Vol. 30, nr 5, 526-536 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    The porosity of a calcium phosphate cement is a key parameter as it affects several important properties of the cement. However, a successful, non-destructive porosity measurement method that does not include drying has not yet been reported for calcium phosphate cements. The aim of this study was to evaluate isopropanol solvent exchange as such a method. Two different types of calcium phosphate cements were used, one basic (hydroxyapatite) and one acidic (brushite). The cements were allowed to set in an aqueous environment and then immersed in isopropanol and stored under three different conditions: at room temperature, at room temperature under vacuum (300 mbar) or at 37􏰀C. The specimen mass was monitored regularly. Solvent exchange took much longer time to reach steady state in hydroxyapatite cements compared to brushite cements, 350 and 18 h, respectively. Furthermore, the immersion affected the quasi-static compressive strength of the hydroxyapatite cements. However, the strength and phase composition of the brushite cements were not affected by isopropanol immersion, suggesting that isopropanol solvent exchange can be used for brushite calcium phosphate cements. The main advantages with this method are that it is non-destructive, fast, easy and the porosity can be evaluated while the cements remain wet, allowing for further analysis on the same specimen. 

  • 10.
    Ajaxon, Ingrid
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Persson, Cecilia
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Mechanical Properties of Brushite Calcium Phosphate Cements2017Inngår i: The World Scientific Encyclopedia of Nanomedicine and Bioengineering II: Bioimplants, Regenerative Medicine, and Nano-Cancer Diagnosis and Phototherapy: Volume 3: Design of Bioactive Materials for Bone Repair and Regeneration / [ed] Shi, D., Singapore: World Scientific Pte Ltd. , 2017Kapittel i bok, del av antologi (Fagfellevurdert)
  • 11.
    Ajaxon, Ingrid
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Öhman, Caroline
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Persson, Cecilia
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Long-term in vitro degradation of a high-strength brushite cement in water, PBS, and serum solution2015Inngår i: BioMed Research International, ISSN 2314-6133, E-ISSN 2314-6141, 575079Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Bone loss and fractures may call for the use of bone substituting materials, such as calcium phosphate cements (CPCs). CPCs can be degradable, and, to determine their limitations in terms of applications, their mechanical as well as chemical properties need to be evaluated over longer periods of time, under physiological conditions. However, there is lack of data on how the in vitro degradation affects high-strength brushite CPCs over longer periods of time, that is, longer than it takes for a bone fracture to heal. This study aimed at evaluating the long-term in vitro degradation properties of a high-strength brushite CPC in three different solutions: water, phosphate buffered saline, and a serum solution. Microcomputed tomography was used to evaluate the degradation nondestructively, complemented with gravimetric analysis. The compressive strength, chemical composition, and microstructure were also evaluated. Major changes from 10 weeks onwards were seen, in terms of formation of a porous outer layer of octacalcium phosphate on the specimens with a concomitant change in phase composition, increased porosity, decrease in object volume, and mechanical properties. This study illustrates the importance of long-term evaluation of similar cement compositions to be able to predict the material’s physical changes over a relevant time frame. 

  • 12.
    Ajaxon, Ingrid
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Öhman Mägi, Caroline
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Persson, Cecilia
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Compressive fatigue properties of an acidic calcium phosphate cement—effect of phase composition2017Inngår i: Journal of materials science. Materials in medicine, ISSN 0957-4530, E-ISSN 1573-4838, Vol. 28, nr 3, 41Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Calcium phosphate cements (CPCs) are synthetic bone grafting materials that can be used in fracture stabilization and to fill bone voids after, e.g., bone tumour excision. Currently there are several calcium phosphate-based formulations available, but their use is partly limited by a lack of knowledge of their mechanical properties, in particular their resistance to mechanical loading over longer periods of time. Furthermore, depending on, e.g., setting conditions, the end product of acidic CPCs may be mainly brushite or monetite, which have been found to behave differently under quasi-static loading. The objectives of this study were to evaluate the compressive fatigue properties of acidic CPCs, as well as the effect of phase composition on these properties. Hence, brushite cements stored for different lengths of time and with different amounts of monetite were investigated under quasi-static and dynamic compression. Both storage and brushite-to-monetite phase transformation was found to have a pronounced effect both on quasi-static compressive strength and fatigue performance of the cements, whereby a substantial phase transformation gave rise to a lower mechanical resistance. The brushite cements investigated in this study had the potential to survive 5 million cycles at a maximum compressive stress of 13 MPa. Given the limited amount of published data on fatigue properties of CPCs, this study provides an important insight into the compressive fatigue behaviour of such materials. 

  • 13.
    Alarcon, E I
    et al.
    Bio-nanomaterials Chemistry and Engineering Laboratory, Division of Cardiac Surgery, University of Ottawa Heart Institute, 40 Ruskin Street, Rm H5229, Ottawa, Canada.
    Vulesevic, B
    Bio-nanomaterials Chemistry and Engineering Laboratory, Division of Cardiac Surgery, University of Ottawa Heart Institute, 40 Ruskin Street, Rm H5229, Ottawa, Canada.
    Argawal, A
    Bio-nanomaterials Chemistry and Engineering Laboratory, Division of Cardiac Surgery, University of Ottawa Heart Institute, 40 Ruskin Street, Rm H5229, Ottawa, Canada.
    Ross, A
    Bio-nanomaterials Chemistry and Engineering Laboratory, Division of Cardiac Surgery, University of Ottawa Heart Institute, 40 Ruskin Street, Rm H5229, Ottawa, Canada.
    Bejjani, P
    Bio-nanomaterials Chemistry and Engineering Laboratory, Division of Cardiac Surgery, University of Ottawa Heart Institute, 40 Ruskin Street, Rm H5229, Ottawa, Canada.
    Podrebarac, J
    Bio-nanomaterials Chemistry and Engineering Laboratory, Division of Cardiac Surgery, University of Ottawa Heart Institute, 40 Ruskin Street, Rm H5229, Ottawa, Canada.
    Ravichandran, Ranjithkumar
    Linköpings universitet, Institutionen för fysik, kemi och biologi, Molekylär fysik. Linköpings universitet, Tekniska fakulteten.
    Phopase, Jaywant
    Linköpings universitet, Institutionen för fysik, kemi och biologi, Molekylär fysik. Linköpings universitet, Tekniska fakulteten.
    Suuronen, E J
    Bio-nanomaterials Chemistry and Engineering Laboratory, Division of Cardiac Surgery, University of Ottawa Heart Institute, 40 Ruskin Street, Rm H5229, Ottawa, Canada.
    Griffith, May
    Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för cellbiologi. Linköpings universitet, Medicinska fakulteten.
    Coloured cornea replacements with anti-infective properties: expanding the safe use of silver nanoparticles in regenerative medicine.2016Inngår i: Nanoscale, ISSN 2040-3364, E-ISSN 2040-3372, Vol. 8, nr 12, 6484-6489 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Despite the broad anti-microbial and anti-inflammatory properties of silver nanoparticles (AgNPs), their use in bioengineered corneal replacements or bandage contact lenses has been hindered due to their intense yellow coloration. In this communication, we report the development of a new strategy to pre-stabilize and incorporate AgNPs with different colours into collagen matrices for fabrication of corneal implants and lenses, and assessed their in vitro and in vivo activity.

  • 14.
    Allardyce, Benjamin J.
    et al.
    Deakin Univ, Inst Frontier Mat, Geelong, Vic, Australia..
    Rajkhowa, Rangam
    Deakin Univ, Inst Frontier Mat, Geelong, Vic, Australia..
    Dilley, Rodney J.
    Univ Western Australia, Sch Surg, Ear Sci Inst Australia, Nedlands, WA 6009, Australia.;Univ Western Australia, Sch Surg, Ear Sci Ctr, Nedlands, WA 6009, Australia..
    Xie, Zhigang
    Deakin Univ, Inst Frontier Mat, Geelong, Vic, Australia..
    Campbell, Luke
    Univ Melbourne, Dept Otolaryngol, Melbourne, Vic 3010, Australia..
    Keating, Adrian
    Univ Western Australia, Sch Mech & Chem Engn, Nedlands, WA 6009, Australia..
    Atlas, Marcus D.
    Univ Western Australia, Sch Surg, Ear Sci Inst Australia, Nedlands, WA 6009, Australia.;Univ Western Australia, Sch Surg, Ear Sci Ctr, Nedlands, WA 6009, Australia..
    von Unge, Magnus
    Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska och farmaceutiska vetenskapsområdet, centrumbildningar mm, Centrum för klinisk forskning, Västerås. Akershus Univ Hosp, Dept ENT, Oslo, Norway.;Univ Oslo, Oslo, Norway..
    Wang, Xungai
    Deakin Univ, Inst Frontier Mat, Geelong, Vic, Australia..
    Comparative acoustic performance and mechanical properties of silk membranes for the repair of chronic tympanic membrane perforations2016Inngår i: Journal of The Mechanical Behavior of Biomedical Materials, ISSN 1751-6161, E-ISSN 1878-0180, Vol. 64, 65-74 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    The acoustic and mechanical properties of silk membranes of different thicknesses were tested to determine their suitability as a repair material for tympanic membrane perforations. Membranes of different thickness (10-100 mu m) were tested to determine their frequency response and their resistance to pressure loads in a simulated ear canal model. Their mechanical rigidity to pressure loads was confirmed by tensile testing. These membranes were tested alongside animal cartilage, currently the strongest available myringoplasty graft as well as paper, which is commonly used for simpler procedures. Silk membranes showed resonant frequencies within the human hearing range and a higher vibrational amplitude than cartilage, suggesting that silk may offer good acoustic energy transfer characteristics. Silk membranes were also highly resistant to simulated pressure changes in the middle ear, suggesting they can resist retraction, a common cause of graft failure resulting from chronic negative pressures in the middle ear. Part of this strength can be explained by the substantially higher modulus of silk films compared with cartilage. This allows for the production of films that are much thinner than cartilage, with superior acoustic properties, but that still provide the same level of mechanical support as thicker cartilage. Together, these in vitro results suggest that silk membranes may provide good hearing outcomes while offering similar levels of mechanical support to the reconstructed middle ear.

  • 15.
    Aminlashgari, Nina
    et al.
    KTH, Skolan för kemivetenskap (CHE), Fiber- och polymerteknik, Polymerteknologi.
    Höglund, Odd V
    Borg, Niklas
    Hakkarainen, Minna
    KTH, Skolan för kemivetenskap (CHE), Fiber- och polymerteknik, Polymerteknologi.
    Degradation profile and preliminary clinical testing of a resorbable device for ligation of blood vessels2013Inngår i: Acta Biomaterialia, ISSN 1742-7061, E-ISSN 1878-7568, Vol. 9, nr 6, 6898-904 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    A resorbable device for ligation of blood vessels was developed and tested in vitro to reveal the degradation profile of the device and to predict the clinical performance in terms of adequate mechanical support during a healing period of I week. In addition, preliminary clinical testing was performed that showed complete hemostasis and good tissue grip of renal arteries in five pigs. The device was made by injection molding of poly(glycolide-co-trimethylene carbonate) triblock copolymer, and it consisted of a case with a locking mechanism connected to a partly perforated flexible band. A hydrolytic degradation study was carried out for 7, 30 and 60 days in water and buffer medium, following the changes in mass, water absorption, pH and mechanical properties. A new rapid matrix-free laser desorption ionization-mass spectrometry (LDI-MS) method was developed for direct screening of degradation products released into the degradation medium. The combination of LDI-MS and electrospray ionization-mass spectrometry analyses enabled the comparison of the degradation product patterns in water and buffer medium. The identified degradation products were rich in trimethylene carbonate units, indicating preferential hydrolysis of amorphous regions where trimethylene units are located. The crystallinity of the material was doubled after 60 days of hydrolysis, additionally confirming the preferential hydrolysis of trimethylene carbonate units and the enrichment of glycolide units in the remaining solid matrix. The mechanical performance of the perforated band was followed for the first week of hydrolysis and the results suggest that sufficient strength is retained during the healing time of the blood vessels.

  • 16.
    Andersson, Marlene
    et al.
    Department of Anatomy, Physiology and Biochemistry, Swedish University of Agricultural Sciences, Uppsala, Sweden..
    Jia, Qiupin
    Institute of Biological Sciences and Biotechnology, Donghua University, Shanghai, P.R. China..
    Abella, Ana
    ETSI de Caminos and Center for Biomedical Technology, Universidad Politécnica de Madrid, Madrid, Spain..
    Lee, Xiau-Yeen
    ETSI de Caminos and Center for Biomedical Technology, Universidad Politécnica de Madrid, Madrid, Spain..
    Landreh, Michael
    Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, Oxford, UK..
    Purhonen, Pasi
    Department of Biosciences and Nutrition, Karolinska Institutet, Stockholm, Sweden.; School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden..
    Hebert, Hans
    Department of Biosciences and Nutrition, Karolinska Institutet, Stockholm, Sweden.; School of Technology and Health, KTH Royal Institute of Technology, Stockholm, Sweden..
    Tenje, Maria
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Mikrosystemteknik. Uppsala universitet, Science for Life Laboratory, SciLifeLab. Department of Biomedical Engineering, Lund University, Lund, Sweden..
    Robinson, Carol V.
    Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, Oxford, UK..
    Meng, Qing
    Institute of Biological Sciences and Biotechnology, Donghua University, Shanghai, P.R. China..
    Plaza, Gustavo R.
    ETSI de Caminos and Center for Biomedical Technology, Universidad Politécnica de Madrid, Madrid, Spain..
    Johansson, Jan
    Department of Anatomy, Physiology and Biochemistry, Swedish University of Agricultural Sciences, Uppsala, Sweden.; Department of Neurobiology, Care Sciences and Society (NVS), Karolinska Institutet, Stockholm, Sweden.; Karolinska Institutet.
    Rising, Anna
    Department of Anatomy, Physiology and Biochemistry, Swedish University of Agricultural Sciences, Uppsala, Sweden.;Department of Neurobiology, Care Sciences and Society (NVS), Karolinska Institutet, Stockholm, Sweden.; Karolinska Institutet.
    Biomimetic spinning of artificial spider silk from a chimeric minispidroin2017Inngår i: Nature Chemical Biology, ISSN 1552-4450, E-ISSN 1552-4469, Vol. 13, nr 3, 262-264 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Herein we present a chimeric recombinant spider silk protein (spidroin) whose aqueous solubility equals that of native spider silk dope and a spinning device that is based solely on aqueous buffers, shear forces and lowered pH. The process recapitulates the complex molecular mechanisms that dictate native spider silk spinning and is highly efficient; spidroin from one liter of bacterial shake-flask culture is enough to spin a kilometer of the hitherto toughest as-spun artificial spider silk fiber.

  • 17.
    Aronsson, Christopher
    Linköpings universitet, Institutionen för fysik, kemi och biologi, Molekylär fysik. Linköpings universitet, Tekniska fakulteten.
    Tunable and modular assembly of polypeptides and polypeptide-hybrid biomaterials2016Doktoravhandling, med artikler (Annet vitenskapelig)
    Abstract [en]

    Biomaterials are materials that are specifically designed to be in contact with biological systems and have for a long time been used in medicine. Examples of biomaterials range from sophisticated prostheses used for replacing outworn body parts to ordinary contact lenses. Currently it is possible to create biomaterials that can e.g. specifically interact with cells or respond to certain stimuli. Peptides, the shorter version of proteins, are excellent molecules for fabrication of such biomaterials. By following and developing design rules it is possible to obtain peptides that can self-assemble into well-defined nanostructures and biomaterials.

    The aim of this thesis is to create ”smart” and tunable biomaterials by molecular self-assembly using dimerizing –helical polypeptides. Two different, but structurally related, polypeptide-systems have been used in this thesis. The EKIV-polypeptide system was developed in this thesis and consists of four 28-residue polypeptides that can be mixed-and-matched to self-assemble into four different coiled coil heterodimers. The dissociation constant of the different heterodimers range from μM to < nM. Due to the large difference in affinities, the polypeptides are prone to thermodynamic social self-sorting. The JR-polypeptide system, on the other hand, consists of several 42-residue de novo designed helix-loop-helix polypeptides that can dimerize into four-helix bundles. In this work, primarily the glutamic acid-rich polypeptide JR2E has been explored as a component in supramolecular materials. Dimerization was induced by exposing the polypeptide to either Zn2+, acidic conditions or the complementary polypeptide JR2K.

    By conjugating JR2E to hyaluronic acid and the EKIV-polypeptides to star-shaped poly(ethylene glycol), respectively, highly tunable hydrogels that can be self-assembled in a modular fashion have been created. In addition, self-assembly of spherical superstructures has been investigated and were obtained by linking two thiol-modified JR2E polypeptides via a disulfide bridge in the loop region. ŒThe thesis also demonstrates that the polypeptides and the polypeptide-hybrids can be used for encapsulation and release of molecules and nanoparticles. In addition, some of the hydrogels have been explored for 3D cell culture. By using supramolecular interactions combined with bio-orthogonal covalent crosslinking reactions, hydrogels were obtained that enabled facile encapsulation of cells that retained high viability.

    The results of the work presented in this thesis show that dimerizing α–helical polypeptides can be used to create modular biomaterials with properties that can be tuned by specific molecular interactions. The modularity and the tunable properties of these smart biomaterials are conceptually very interesting andmake them useful in many emerging biomedical applications, such as 3D cell culture, cell therapy, and drug delivery

    .

  • 18.
    Aronsson, Henrik
    Linköpings universitet, Institutionen för fysik, kemi och biologi.
    Local Delivery of Bisphosphonates from FibMat Matrix2008Independent thesis Basic level (professional degree), 20 poäng / 30 hpOppgave
    Abstract [en]

    Improving the functionality and reducing revision rates are important driving forces in the development of orthopaedic implants. FibMat is a fibrinogen based matrix developed towards commercialisation by the company Optovent AB. This matrix can be coated on implants and act as a local drug delivery system for bisphosphonates (BPs). BPs are drugs inhibiting bone resorption, and applied with FibMat to improve stability of implants in bone, e.g. when fixing bone fractures. In this thesis, FibMat loaded with BP (FibMat/BP) was coated on stainless-steel screws and titanium screws in order to investigate some technology properties relevant to its clinical applicability. Bone-mimicking materials were used to study scrape-off effect upon insertion. The coagulation properties of fibrinogen as well as the structural properties of BPs were studied after exposure to gamma radiation.

    The screws were coated with FibMat and BP (alendronate and 14C-alendronate) using standard coupling techniques. The total amount and distribution of BP after insertion was measured by liquid scintillation and autoradiography. Coagulation assays were performed in order to determine the coagulation properties of fibrinogen, exposed to doses up to 35 kGy, mixed with thrombin. The structural properties of four different BPs (alendronate, pamidronate, zoledronate and ibandronate), exposed to doses up to 35 kGy were analysed by transmission infrared spectroscopy.

    The results show that FibMat/BP coating on porous stainless-steel screws is virtually unaffected by insertion into bone materials. The anodised, planar titanium screws are more affected by the insertion process, but an even BP distribution in the cancellous material is indicated. The coagulation assays show that gamma-irradiated fibrinogen has a slower coagulation process compared to non-irradiated fibrinogen and form interrupted network unable to clot. The chemical structures of the BPs seem unaffected by exposure to gamma irradiation. In conclusion, the FibMat/BP is a promising technology for local distribution of BP in conjunction with bone implants.

  • 19.
    Asif, Sana
    et al.
    Uppsala University.
    Nilsson Ekdahl, Kristina
    Linnéuniversitetet, Fakulteten för Hälso- och livsvetenskap (FHL), Institutionen för kemi och biomedicin (KOB). Uppsala University.
    Fromell, Karin
    Uppsala University.
    Gustafson, Elisabet
    Uppsala University Hospital.
    Barbu, Andreea
    Uppsala University.
    Le Blanc, Katarina
    Karolinska Institutet ; Karolinska University Hospital.
    Nilsson, Bo
    Uppsala University.
    Teramura, Yuji
    Uppsala University ; The University of Tokyo, Japan.
    Heparinization of cell surfaces with short peptide-conjugated PEG-lipid regulates thromboinflammation in transplantation of human MSCs and hepatocytes2016Inngår i: Acta Biomaterialia, ISSN 1742-7061, E-ISSN 1878-7568, Vol. 35, 194-205 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Infusion of therapeutic cells into humans is associated with immune responses, including thromboinflammation, which result in a large loss of transplanted cells\ To address these problems, heparinization of the cell surfaces was achieved by a cell-surface modification technique using polyethylene glycol conjugated phospholipid (PEG-lipid) derivatives. A short heparin-binding peptide was conjugated to the PEG-lipid for immobilization of heparin conjugates on the surface of human mesenchymal stem cells (hMSCs) and human hepatocytes. Here three kinds of heparin-binding peptides were used for immobilizing heparin conjugates and examined for the antithrombogenic effects on the cell surface. The heparinized cells were incubated in human whole blood to evaluate their hemocompatibility by measuring blood parameters such as platelet count, coagulation markers, complement markers, and Factor Xa activity. We found that one of the heparin-binding peptides did not show cytotoxicity after the immobilization with heparin conjugates. The degree of binding of the heparin conjugates on the cell surface (analyzed by flow cytometer) depended on the ratio of the active peptide to control peptide. For both human MSCs and hepatocytes in whole-blood experiments, no platelet aggregation was seen in the heparin conjugate-immobilized cell group vs. the controls (non-coated cells or control peptide). Also, the levels of thrombin-antithrombin complex (TAT), C3a, and sC5b-9 were significantly lower than those of the controls, indicating a lower activation of coagulation and complement. Factor Xa analysis indicated that the heparin conjugate was still active on the cell surface at 24 h post-coating. It is possible to immobilize heparin conjugates onto hMSC and human hepatocyte surfaces and thereby protect the cell surfaces from damaging thromboinflammation. Statement of Signigficance We present a promising approach to enhance the biocompatibility of therapeutic cells. Here we used short peptide-conjugated PEG-lipid for cell surface modification and heparin conjugates for the coating of human hepatocytes and MSCs. We screened the short peptides to find higher affinity for heparinization of cell surface and performed hemocompatibility assay of heparinized human hepatocytes and human MSCs in human whole blood. Using heparin-binding peptide with higher affinity, not only coagulation activation but also complement activation was significantly suppressed. Thus, it was possible to protect human hepatocytes and human MSCs from the attack of thromboinflammatory activation, which can contribute to the improvement graft survival. (C) 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  • 20.
    Aulin, Cecilia
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Kemiska sektionen, Institutionen för materialkemi.
    Extracellular Matrix Based Materials for Tissue Engineering2010Doktoravhandling, med artikler (Annet vitenskapelig)
    Abstract [en]

    The extracellular matrix is (ECM) is a network of large, structural proteins and polysaccharides, important for cellular behavior, tissue development and maintenance. Present thesis describes work exploring ECM as scaffolds for tissue engineering by manipulating cells cultured in vitro or by influencing ECM expression in vivo. By culturing cells on polymer meshes under dynamic culture conditions, deposition of a complex ECM could be achieved, but with low yields. Since the major part of synthesized ECM diffused into the medium the rate limiting step of deposition was investigated. This quantitative analysis showed that the real rate limiting factor is the low proportion of new proteins which are deposited as functional ECM. It is suggested that cells are pre-embedded in for example collagen gels to increase the steric retention and hence functional deposition.

    The possibility to induce endogenous ECM formation and tissue regeneration by implantation of growth factors in a carrier material was investigated. Bone morphogenetic protein-2 (BMP-2) is a growth factor known to be involved in growth and differentiation of bone and cartilage tissue. The BMP-2 processing and secretion was examined in two cell systems representing endochondral (chondrocytes) and intramembranous (mesenchymal stem cells) bone formation. It was discovered that chondrocytes are more efficient in producing BMP-2 compared to MSC. The role of the antagonist noggin was also investigated and was found to affect the stability of BMP-2 and modulate its effect. Finally, an injectable gel of the ECM component hyaluronan has been evaluated as delivery vehicle in cartilage regeneration. The hyaluronan hydrogel system showed promising results as a versatile biomaterial for cartilage regeneration, could easily be placed intraarticulary and can be used for both cell based and cell free therapies.

  • 21.
    Ballo, Ahmed
    et al.
    Gothenburg University.
    Omar, Omar
    Gothenburg Univerity.
    Xia, Wei
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Palmquist, Anders
    Gothenburg University.
    Dental Implant Surfaces Implant Dentistry - A Rapidly Evolving Practic: Physicochemical Properties, Biological Performance, and Trends2011Inngår i: Implant Dentistry: A Rapidly Evolving Practice / [ed] Ilser Turkyilmaz, INTECH , 2011Kapittel i bok, del av antologi (Fagfellevurdert)
  • 22.
    Beaussant Törne, Karin
    et al.
    KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik.
    Khan, Fareed Ashraf
    Örnberg, A.
    Weissenrieder, Jonas
    KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik.
    Zn-Mg and Zn-Ag degradation mechanism under biologically relevant conditionsManuskript (preprint) (Annet vitenskapelig)
    Abstract [en]

    Zinc alloys form a promising new class of biodegradable metals that combine suitable mechanical properties with the favorable degradation properties of pure zinc. However, the current understanding of the influence of alloying elements on the corrosion of zinc alloys, in biologically relevant media, is limited. We studied the degradation of three alloys, Zn 4 wt% Ag, Zn 0.5 wt% Mg and Zn 3 wt% Mg by in situ electrochemical impedance spectroscopy (EIS). After exposure for 1h or 30 days the samples were characterized by infrared spectroscopy and scanning electron microscopy (SEM). The presence of secondary phases in the alloy microstructure induced selective corrosion and increased degradation rate. An increase in surface inhomogeneity was evident by EIS analysis both at short (hours) as well as long immersion times (days). The microgalvanic corrosion of the Zn-Ag alloy resulted in enrichment of the AgZn3 phase at the sample surface. The enrichment of Ag and potential release of AgZn3 particles may result in complications during the tissue regeneration. The Zn-Mg alloy surface was depleted of the Mg-rich phase after 8-12 days. The selective dissolution caused local precipitation of2corrosion products and a thicker corrosion layer with larger pore size consistent with increased corrosion rate.

    Fulltekst tilgjengelig fra 2018-10-01 14:30
  • 23.
    Beaussant Törne, Karin
    et al.
    KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik.
    Örnberg, A.
    Weissenrieder, Jonas
    KTH, Skolan för teknikvetenskap (SCI), Tillämpad fysik.
    Characterization of the Protective Layer Formed on Zinc in Whole BloodManuskript (preprint) (Annet vitenskapelig)
    Abstract [en]

    The advantageous degradation properties of zinc in a biological environment are related to the presence of a protective corrosion layer composed of both organic and inorganic components. However, the mechanisms governing its formation and how the organic species influence its properties have not been established. Here we study the protective layer formation during anodic polarization in whole blood by in situ electrochemical impedance spectroscopy (EIS) as well as infrared spectroscopy and scanning electron microscopy. Simulated body fluid (m-SBF) was used as a reference media to discern the influence of the organic species present in whole blood. Protective zinc phosphate layers form on the Zn surface in both solutions, but of different nature and through diverse mechanisms. In m-SBF the passivating thin film formation occur already at open circuit potential, reducing the corrosion current compared to exposure in whole blood by a factor of 103. The high corrosion current in whole blood can be explained by a process including rapid protein adsorption preventing the initial formation of a protective phosphate layer. EIS analysis detected an inductive arc in whole blood at low overpotentials, before the onset of protective film formation, indicating the presence of adsorbed Zn2ions. The coverage of Zn ions approach 100% of the active surface at 110 mV. At this critical surface coverage a reaction between the adsorbed Zn ions and PO42- takes place which results in formation of a protective, porous, film of ~1 μm thickness. The inorganic component of the protective film formed in whole blood was characterized as Zn(PO4)2(OH)2·3H2O.

    Fulltekst tilgjengelig fra 2018-10-01 14:26
  • 24.
    Berts, Ida
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Kemiska sektionen, Institutionen för kemi - Ångström. Uppsala universitet, Science for Life Laboratory, SciLifeLab.
    Ossipov, Dmitri
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Kemiska sektionen, Institutionen för kemi - Ångström. Uppsala universitet, Science for Life Laboratory, SciLifeLab.
    Fragneto, Giovanna
    Institut Laue-Langevin.
    Frisk, Andreas
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Fysiska sektionen, Institutionen för fysik och astronomi, Materialfysik.
    Rennie, Adrian. R
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Fysiska sektionen, Institutionen för fysik och astronomi, Materialfysik.
    Polymeric Smart Coating Strategy for Titanium Implants2014Inngår i: Advanced Engineering Materials, ISSN 1438-1656, E-ISSN 1527-2648, Vol. 16, nr 11, 1340-1350 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Hyaluronan based hydrogel coatings can mimic extracellular matrix components and incorporate growth factors that can be released during a progressive degradation while new tissue regenerates. This paper describes a structural characterization of a hydrogel coating made of modified hyaluronan polymers and how these coatings interact with bone morphogenetic protein-2 (BMP-2). Quartz crystal microbalance and neutron reflectivity measurements were used for in-situ, real-time measurements of the adsorption properties of polymers and proteins on smooth titanium oxide surfaces that mimic implant products in orthopedics. The adsorption of BMP-2 on a bare titanium oxide surface is compared to that on titanium oxide coated with different chemically modified hyaluronan, the most important being hyaluronan with bisphosphonate groups (HA-BP). The subsequent release of the BMP-2 from these hydrogel coatings could be triggered by calcium ions. The amount of adsorbed protein on the surfaces as well as the amount of released protein both depend on the type of hyaluronan coating. We conclude that HA-BP coated titanium oxide surfaces provide an excellent material for growth factor delivery in-vivo.

  • 25.
    Bjurhager, Ingela
    et al.
    KTH, Skolan för kemivetenskap (CHE), Fiber- och polymerteknik.
    Gamstedt, E. Kristofer
    Keunecke, Daniel
    Niemz, Peter
    Berglund, Lars A.
    KTH, Skolan för kemivetenskap (CHE), Fiber- och polymerteknik, Biokompositer. KTH, Skolan för kemivetenskap (CHE), Centra, Wallenberg Wood Science Center.
    Mechanical performance of yew (Taxus baccata L.) from a longbow perspective2013Inngår i: Holzforschung, ISSN 0018-3830, Vol. 67, nr 7, 763-770 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Yew (Taxus baccata L.) longbow was the preferred weapon in the Middle Ages until the emergence of guns. In this study, the tensile, compression, and bending properties of yew were investigated. The advantage of yew over the other species in the study was also confirmed by a simple beam model. The superior toughness of yew has the effect that a yew longbow has a higher range compared with bows made from other species. Unexpectedly, the mechanical performance of a bow made from yew is influenced by the juvenile-to-mature wood ratio rather than by the heartwood-to-sapwood ratio. A yew bow is predicted to have maximized performance at a juvenile wood content of 30-50%, and located at the concave side (the compressive side facing the bowyer). Here, the stiffness and yield stress in compression should be as high as possible.

  • 26. Blau, Axel
    et al.
    Murr, Angelika
    Wolff, Sandra
    Sernagor, Evelyne
    Medini, Paolo
    Iurilli, Giuliano
    Ziegler, Christiane
    Benfenati, Fabio
    Flexible, all-polymer microelectrode arrays for the capture of cardiac and neuronal signals2011Inngår i: Biomaterials, ISSN 0142-9612, E-ISSN 1878-5905, Vol. 32, nr 7, 1778-1786 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Microelectrode electrophysiology has become a widespread technique for the extracellular recording of bioelectrical signals. To date, electrodes are made of metals or inorganic semiconductors, or hybrids thereof. We demonstrate that these traditional conductors can be completely substituted by highly flexible electroconductive polymers. Pursuing a two-level replica-forming strategy, conductive areas for electrodes, leads and contact pads are defined as microchannels in poly(dimethylsiloxane) (PDMS) as a plastic carrier and track insulation material. These channels are coated by films of organic conductors such as polystyrenesulfonate-doped poly(3,4-ethylenedioxy-thiophene) (PEDOT:PSS) or filled with a graphite-PDMS (gPDMS) composite, either alone or in combination. The bendable, somewhat stretchable, non-cytotoxic and biostable all-polymer microelectrode arrays (polyMEAs) with a thickness below 500 μm and up to 60 electrodes reliably capture action potentials (APs) and local field potentials (LFPs) from acute preparations of heart muscle cells and retinal whole mounts, in vivo epicortical and epidural recordings as well as during long-term in vitro recordings from cortico-hippocampal co-cultures.

  • 27.
    Blomgran, Parmis
    et al.
    Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för Kirurgi, Ortopedi och Onkologi. Linköpings universitet, Medicinska fakulteten.
    Hammerman, Malin
    Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för Kirurgi, Ortopedi och Onkologi. Linköpings universitet, Medicinska fakulteten.
    Aspenberg, Per
    Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för Kirurgi, Ortopedi och Onkologi. Linköpings universitet, Medicinska fakulteten. Region Östergötland, Centrum för kirurgi, ortopedi och cancervård, Ortopedkliniken i Linköping.
    Systemic corticosteroids improve tendon healing when given after the early inflammatory phase2017Inngår i: Scientific Reports, ISSN 2045-2322, E-ISSN 2045-2322, Vol. 7, 12468Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Inflammation initiates tendon healing and then normally resolves more or less completely. Unresolved inflammation might disturb the remodeling process. We hypothesized that suppression of inflammation during the early remodeling phase by systemic dexamethasone treatment can improve healing. 36 rats underwent Achilles tendon transection and were randomized to dexamethasone or saline on days 0-4 after surgery (early inflammatory phase), and euthanasia day 7. Another 54 rats received injections days 5-9 (early remodeling phase) and were euthanized day 12 for mechanical, histological and flow cytometric evaluation. Dexamethasone treatment days 0-4 reduced the cross-sectional area, peak force and stiffness by day 7 to less than half (p amp;lt; 0.001 for all), while material properties (peak stress and elastic modulus) were not significantly affected. In contrast, dexamethasone treatment days 5-9 increased peak force by 39% (p = 0.002) and stiffness by 58% (p amp;lt; 0.001). The cross-sectional area was reduced by 42% (p amp;lt; 0.001). Peak stress and elastic modulus were more than doubled (p amp;lt; 0.001 for both). Semi-quantitative histology at day 12 showed that late dexamethasone treatment improved collagen alignment, and flow cytometry revealed reduced numbers of CD8a(+) cytotoxic T cells in the tendon callus. These results suggest that downregulation of lingering inflammation during the early remodeling phase can improve healing.

  • 28. Bou-Francis, Antony
    et al.
    Lopez, Alejandro
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Persson, Cecilia
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Hall, Richard M.
    Kapur, Nikil
    Assessing cement injection behaviour in cancellous bone: An in vitro study using flow models2014Inngår i: Journal of biomaterials applications, ISSN 0885-3282, E-ISSN 1530-8022, Vol. 29, nr 4, 582-594 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Understanding the cement injection behaviour during vertebroplasty and accurately predicting the cement placement within the vertebral body is extremely challenging. As there is no standardized methodology, we propose a novel method using reproducible and pathologically representative flow models to study the influence of cement properties on injection behaviour. The models, confined between an upper glass window and a lower aluminium plate, were filled with bone marrow substitute and then injected (4, 6 and 8min after cement mixing) with commercially available bone cements (SimplexP, Opacity+, OsteopalV and Parallax) at a constant flow rate (3mL/min). A load cell was used to measure the force applied on the syringe plunger and calculate the peak pressure. A camera was used to monitor the cement flow during injection and calculate the following parameters when the cement had reached the boundary of the models: the time to reach the boundary, the filled area and the roundness. The peak pressure was comparable to that reported during clinical vertebroplasty and showed a similar increase with injection time. The study highlighted the influence of cement formulations and model structure on the injection behaviour and showed that cements with similar composition/particle size had similar flow behaviour, while the introduction of defects reduced the time to reach the boundary, the filled area and the roundness. The proposed method provides a novel tool for quick, robust differentiation between various cement formulations through the visualization and quantitative analysis of the cement spreading at various time intervals.

  • 29.
    Broitman, Esteban
    et al.
    Linköpings universitet, Institutionen för fysik, kemi och biologi, Tunnfilmsfysik. Linköpings universitet, Tekniska högskolan.
    Bojorge, C
    CINSO, Argentina.
    Elhordoy, F
    Instituto de Física & CINQUIFIMA, Uruguay.
    Kent, V.
    Instituto de Física & CINQUIFIMA, Uruguay.
    Zanini Gadioli, G
    Instituto de Física Gleb Wataghin, Brazil.
    Marotti, R.
    Instituto de Física & CINQUIFIMA, Uruguay.
    Canepa, H
    CINSO, Argentina.
    Dalchiele, E. A.
    Instituto de Física & CINQUIFIMA, Uruguay.
    Comparative study on the properties of ZnO nanowires and nanocrystalline thin films2012Inngår i: Surface & Coatings Technology, ISSN 0257-8972, E-ISSN 1879-3347, Vol. 213, 59-64 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    The microstructural, morphological, optical and water-adsorption properties of nanocrystalline ZnO thin films and ZnO nanowires were studied and compared. The ZnO thin films were obtained by a sol–gel process, while the ZnO nanowires were electrochemically grown onto a ZnO sol–gel spin-coated seed layer. Thin films and nanowire samples were deposited onto crystalline quartz substrates covered by an Au electrode, able to be used in a quartz crystal microbalance. X-ray diffraction measurements reveal in both cases a typical diffraction pattern of ZnO wurtzite structure. Scanning electron microscopic images of nanowire samples show the presence of nanowires with hexagonal sections, with diameters ranging from 30 to 90 nm. Optical characterization reveals a bandgap energy of 3.29 eV for the nanowires and 3.35 eV for the thin films. A quartz crystal microbalance placed in a vacuum chamber was used to quantify the amount and kinetics of water adsorption onto the samples. Nanowire samples, which have higher surface areas than the thin films, adsorb significantly more water.

  • 30.
    Brunette, Isabelle
    et al.
    University of Montreal, Canada.
    Alarcon, Emilio
    University of Ottawa Heart Institute, Canada.
    Griffith, May
    Linköpings universitet, Institutionen för klinisk och experimentell medicin, Avdelningen för cellbiologi. Linköpings universitet, Medicinska fakulteten.
    Cornea Regeneration as an Alternative to Human Donor Transplantation2015Inngår i: European Ophthalmic Review, ISSN 1756-1795, Vol. 9, nr 2, 111-114 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    There is a need for an alternative to human donor corneas as the availability of good-quality tissues remains limited, with this situation potentially worsening as the population in many countries is progressively ageing. There have been numerous attempts to develop corneal equivalent as alternatives to donated human corneas as well as prostheses. In this short review, we focus on the efforts in bioengineering implants that promote regeneration by Canadian researchers, including our current team of authors. The examples of technologies developed that we describe include biomaterials that allow for partial regeneration of corneal tissue, self-assembled cornea constructs and cell-free corneal implants that promoted regeneration when evaluated in clinical trials in Europe.

  • 31.
    Bäcklund, Fredrik G.
    et al.
    Linköpings universitet, Institutionen för fysik, kemi och biologi, Biomolekylär och Organisk Elektronik. Linköpings universitet, Tekniska fakulteten.
    Pallbo, Jon
    Linköpings universitet, Institutionen för fysik, kemi och biologi, Biomolekylär och Organisk Elektronik. Linköpings universitet, Tekniska fakulteten.
    Solin, Niclas
    Linköpings universitet, Institutionen för fysik, kemi och biologi, Biomolekylär och Organisk Elektronik. Linköpings universitet, Tekniska fakulteten.
    Controlling Amyloid Fibril Formation by Partial Stirring2016Inngår i: Biopolymers, ISSN 0006-3525, E-ISSN 1097-0282, Vol. 105, nr 5, 249-259 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Many proteins undergoes self-assembly into fibrillar structures known as amyloid fibrils. During the self-assembly process related structures, known as spherulites, can be formed. Herein we report a facile method where the balance between amyloid fibrils and spherulites can be controlled by stirring of the reaction mixture during the initial stages of the self-assembly process. Moreover, we report how this methodology can be used to prepare non-covalently functionalized amyloid fibrils. By stirring the reaction mixture continuously or for a limited time during the lag phase the fibril length, and hence the propensity to form liquid crystalline phases, can be influenced. This phenomena is utilized by preparing films consisting of aligned protein fibrils incorporating the laser dye Nile red. The resulting films display polarized Nile red fluorescence.

  • 32.
    Bäcklund, Fredrik G.
    et al.
    Linköpings universitet, Institutionen för fysik, kemi och biologi, Biomolekylär och Organisk Elektronik. Linköpings universitet, Tekniska fakulteten.
    Solin, Niclas
    Linköpings universitet, Institutionen för fysik, kemi och biologi, Biomolekylär och Organisk Elektronik. Linköpings universitet, Tekniska fakulteten.
    Tuning the aqueous self-assembly process of insulin by a hydrophobic additive2015Inngår i: RSC ADVANCES, ISSN 2046-2069, Vol. 5, nr 112, 92254-92262 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Biomolecular self-assembly is an efficient way of preparing soft-matter based materials. Herein we report a novel method, based on the use of insoluble additives in aqueous media, for influencing the self-assembly process. Due to their low solubility, the use of hydrophobic additives in aqueous media is problematic; however, by mixing the additive with the biomolecule in the solid state, prior to solvation, this problem can be circumvented. In the investigated self-assembly system, where bovine insulin self-assembles into spherical structures, the inclusion of the hydrophobic material α-sexithiophene (6T) results in significant changes in the self-assembly process. Under our reaction conditions, in the case of materials prepared from insulin-only the growth of spherulites typically stops at a diameter of 150μm. However, by adding 2 weight % of hydrophobic material, spherulite growth continues up to diameters in the mm-range. The spherulites incorporate 6T and are thus fluorescent. The method reported herein should be of interest to all scientists working in the field of self-assembly as the flexible materials preparation, based simply on co-grinding of commercially available materials, adds another option to influence the structure and properties of products formed by  self-assembly reactions.

  • 33.
    Bäcklund, Fredrik Gustaf
    et al.
    Linköpings universitet, Institutionen för fysik, kemi och biologi, Biomolekylär och Organisk Elektronik. Linköpings universitet, Tekniska fakulteten.
    Ajjan, Fátima Nadia
    Linköpings universitet, Institutionen för fysik, kemi och biologi, Biomolekylär och Organisk Elektronik. Linköpings universitet, Tekniska fakulteten.
    Solin, Niclas
    Linköpings universitet, Institutionen för fysik, kemi och biologi, Biomolekylär och Organisk Elektronik. Linköpings universitet, Tekniska fakulteten.
    Convection Induced Air-Water Interface Assembly of Amyloid FibrilsManuskript (preprint) (Annet vitenskapelig)
    Abstract [en]

    We report that hydrophobically modified amyloid fibrils form macroscopic films at the air-water interface. The hydrophobically modified fibrils are prepared in a two step process. First bovine insulin is ground with a hydrophobic compound. The resulting material is dissolved in acidic water and heated to induce assembly into fibrils incorporating the hydrophobic compounds. Upon dilution followed by asymmetric heating, resulting in convection flow, the fibrills form highly ordered films with thicknesses from 80 nm and up. The thickness of the film can be controlled by the fibril concentration and/or reaction time. The films contain anisotropic domains spanning several square centimeters. In addition, the films contains ordered assemblies of dyes that display emission of polarized light.

  • 34.
    Cai, Bing
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Ceramic Materials for Administration of Potent Drugs2015Doktoravhandling, med artikler (Annet vitenskapelig)
    Abstract [en]

    This thesis aimed to investigate and document the potential of applying ceramics in two specific drug delivery applications: tamper-resistant opioid formulations and transdermal enhancement protrusions.

    Geopolymers were developed into the matrix for a tamper-resistant formulation, aiming to protect drug substances from non-medical abuse. The synthesis conditions and excipients composition of the geopolymer-based formulation were modified in this work to facilitate a stable and extended drug delivery. Results showed that 37ºC 100% humidity for 48 hours were applicable conditions to obtain geopolymer with suitable mechanical strength and porosity. Moreover, it was found that the integration of poly(methyl acrylate) into the geopolymer-based formulation could reduce the drug release at low pH and, meanwhile, maintain the mechanical strength. Therefore, the geopolymer-based drug formulations concluded from these studies were applied in oral and transdermal delivery systems. Evidence of the tamper-resistance of geopolymer-based oral and transdermal formulations was documented and compared to the corresponding commercial opioid formulations. The results provided experimental support for the positive effects of geopolymers as drug carriers for the tamper-resistance of oral and transdermal delivery systems.

    Self-setting bioceramics, calcium phosphate and calcium sulfate were fabricated into transdermal enhancement protrusions in this work for the first time. Results showed that, under mild conditions, both bioceramics could form pyramid-shaped needles in the micron size. The drug release from these needles could be controlled by the bulk surface area, porosity and degradation of the bioceramics. An in vitro insertion test showed that the bioceramic microneedles had enough mechanical strength to insert into skin. Further optimization on the geometry of needles and the substrate material was also performed. The higher aspect-ratio needles with a flexible and self-swellable substrate could release most of the drug content within 4 hours and could penetrate through the stratum corneum by manual insertion. This study explored the potential application of bioceramics in transdermal enhancement protrusions and showed promising indication of their future developments.

  • 35.
    Cai, Bing
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Engqvist, Håkan
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Bredenberg, Susanne
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Aluminum release from geopolymer-based opioid formulation2014Konferansepaper (Fagfellevurdert)
  • 36.
    Cai, Bing
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Engqvist, Håkan
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Bredenberg, Susanne
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Evaluation of the effect of polymer content on drug release and mechanical strength of a geopolymer ER formulation for opioid drugs2014Konferansepaper (Fagfellevurdert)
  • 37.
    Cai, Bing
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Söderkvist, Karin
    Engqvist, Håkan
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Bredenberg, Susanne
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    A new screening in-vitro method to study drug release in early development of transdermal drug delivery systems2012Inngår i: European Cells and Materials, ISSN 1473-2262, Vol. 23, nr Suppl. 5, 22- s.Artikkel i tidsskrift (Fagfellevurdert)
  • 38.
    Cai, Bing
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Xia, Wei
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Bredenberg, Susanne
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Engqvist, Håkan
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Development and evaluation of self-setting bioceramic microneedles2014Konferansepaper (Fagfellevurdert)
  • 39.
    Cai, Bing
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Xia, Wei
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Bredenberg, Susanne
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Li, Hao
    Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Öron-, näs- och halssjukdomar.
    Engqvist, Håkan
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Bioceramic microneedles with flexible and self-swelling substrate2015Inngår i: European journal of pharmaceutics and biopharmaceutics, ISSN 0939-6411, E-ISSN 1873-3441, Vol. 94, 404-410 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    To reduce the effort required to penetrate the skin and optimize drug release profiles, bioceramic microneedle arrays with higher-aspect-ratio needles and a flexible and self-swelling substrate have been developed. Swelling of the substrate can assist in separating it from the needles and leave them in the skin as a drug depot. The preparation procedures for this bioceramic microneedle are described in the paper. Clonidine hydrochloride, the model drug, was released in a controlled manner by the microneedle device in vitro. Results showed that the microneedle array with a flexible and self-swelling substrate released the drug content faster than the array with a rigid substrate. Disintegration of the needle material and diffusion of the drug molecules are believed as the main control mechanisms of the drug release from these microneedle arrays. Ex vivo skin penetration showed that they can effectively penetrate the stratum corneum without an extra device. This work represents a progression in the improvement of bioceramic microneedles for transdermal drug delivery.

  • 40.
    Cai, Bing
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Xia, Wei
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Engqvist, Håkan
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Bredenberg, Susanne
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Bioceramic microneedles with flexible and self-swelling substrateArtikkel i tidsskrift (Annet vitenskapelig)
  • 41.
    Cai, Yanling
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Nanoteknologi och funktionella material.
    Strömme, Maria
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Nanoteknologi och funktionella material.
    Melhus, Åsa
    Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för medicinska vetenskaper, Klinisk mikrobiologi och infektionsmedicin, Klinisk bakteriologi.
    Engqvist, Håkan
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Welch, Ken
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Nanoteknologi och funktionella material.
    Photocatalytic inactivation of biofilms on bioactive dental adhesives2014Inngår i: Journal of Biomedical Materials Research. Part B - Applied biomaterials, ISSN 1552-4973, E-ISSN 1552-4981, Vol. 102, nr 1, 62-67 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    Biofilms are the most prevalent mode of microbial life in nature and are 10-1000 times more resistant to antibiotics than planktonic bacteria. Persistent biofilm growth associated at the margin of a dental restoration often leads to secondary caries, which remains a challenge in restorative dentistry. In this work, we present the first in vitro evaluation of on-demand photocatalytic inactivation of biofilm on a novel dental adhesive containing TiO2 nanoparticles. Streptococcus mutans biofilm was cultured on this photocatalytic surface for 16 h before photocatalytic treatment with ultraviolet-A (UV-A) light. UV-A doses ranging from 3 to 43 J/cm(2) were applied to the surface and the resulting viability of biofilms was evaluated with a metabolic activity assay incorporating phenol red that provided a quantitative measure of the reduction in viability due to the photocatalytic treatments. We show that an UV-A irradiation dose of 8.4 J/cm(2) leads to one order of magnitude reduction in the number of biofilm bacteria on the surface of the dental adhesives while as much as 5-6 orders of magnitude reduction in the corresponding number can be achieved with a dose of 43 J/cm(2). This material maintains its functional properties as an adhesive in restorative dentistry while offering the possibility of a novel dental procedure in the treatment or prevention of bacterial infections via on-demand UV-A irradiation. Similar materials could be developed for the treatment of additional indications such as peri-implantits.

  • 42.
    Cai, Yanling
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Nanoteknologi och funktionella material.
    Strømme, Maria
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Nanoteknologi och funktionella material.
    Welch, Ken
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Nanoteknologi och funktionella material.
    Bacteria viability assessment after photocatalytic treatment2014Inngår i: 3 Biotech, ISSN 2190-5738, E-ISSN 2190-5738, Vol. 4, nr 2, 149-157 s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    The aim of the present work was to evaluate several methods for analyzing the viability of bacteria after antibacterial photocatalytic treatment. Colony-forming unit (CFU) counting, metabolic activity assays based on resazurin and phenol red and the Live/Dead® BacLight™ bacterial viability assay (Live/Dead staining) were employed to assess photocatalytically treated Staphylococcus epidermidis and Streptococcus mutans. The results showed conformity between CFU counting and the metabolic activity assays, while Live/Dead staining showed a significantly higher viability post-treatment. This indicates that the Live/Dead staining test may not be suitable for assessing bacterial viability after photocatalytic treatment and that, in general, care should be taken when selecting a method for determining the viability of bacteria subjected to photocatalysis. The present findings are expected to become valuable for the development and evaluation of photocatalytically based disinfection applications

  • 43.
    Cardemil, Carina
    Department of Biomaterials, Institute of Clinical Sciences, The Sahlgrenska Academy at the University of Gothenburg, Göteborg, Sweden.
    Effects of antiresorptive agents on inflammation and bone regeneration in different osseous sites - experimental and clinical studies2014Doktoravhandling, med artikler (Annet vitenskapelig)
    Abstract [en]

    The biological mechanisms involved in bone regeneration in osteoporotic bone and the effect of antiresorptive drugs in relation to surgically inserted biomaterials are not fully understood. Improved osseointegration of titanium implants but also adverse effects of antiresorptive therapies, such as osteonecrotic jaw have been described in the literature. The aims of this research project were, firstly, to investigate and to understand the biological events determining bone regeneration and implant integration, after administration of antiresorptive agents; secondly, to determine the cellular and molecular patterns of bone regeneration at implants and synthetic bone substitutes under osteoporotic conditions and, thirdly, to determine how different skeletal sites are affected. The present research included a study of jawbone morphology and gene expression in patients treated with systemic bisphosphonates. When compared to controls, higher gene expression levels of IL-1β was observed in bisphosphonate treated patients with osteonecrosis while bisphosphonate treated patients without necrosis showed lower expression levels of caspase 8, an apoptosis marker involved in the immune response. In ovariectomised rats, zoledronic acid resulted in site-specific differences in the rate of osseointegration and also of gene expression involved in bone healing and regeneration. Strontium-doped calcium phosphate inserted in the rat femur induced lower expression of osteoclastic markers compared to hydroxyapatite and higher bone formation in the periphery of the defects. Whereas major structural changes were demonstrated in the long bones of the ovariectomised rat, less structural alterations were shown in the mandible. However, ovariectomy resulted in lower expression of genes coding for bone formation and angiogenesis in the mandible. In conclusion, the present study shows that the mandible is differently affected by experimentally induced estrogen deficiency than the long bones. Bisphosphonates, administered systemically to estrogen deficient animals, impair osseointegration in the mandible, at least partly related to a downregulation of genes important for the osteogenic process. These observations may have implications for understanding the mechanisms involved in the deranged bone healing observed in the jawbone of bisphosphonate treated patients.

  • 44.
    Cardemil, Carina
    et al.
    University of Gothenburg.
    Elgali, Ibrahim
    University of Gothenburg.
    Xia, Wei
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Emanuelsson, Lena
    Gothenburg University.
    Norlindh, Birgitta
    University of Gothenburg.
    Omar, Omar
    University of Gothenburg.
    Thomsen, Peter
    Gothenburg University.
    Strontium-Doped Calcium Phosphate and Hydroxyapatite Granules Promote Different Inflammatory and Bone Remodelling Responses in Normal and Ovariectomised Rats2013Inngår i: PLoS ONE, ISSN 1932-6203, Vol. 8, nr 12, e84932- s.Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    The healing of bone defects may be hindered by systemic conditions such as osteoporosis. Calcium phosphates, with or without ion substitutions, may provide advantages for bone augmentation. However, the mechanism of bone formation with these materials is unclear. The aim of this study was to evaluate the healing process in bone defects implanted with hydroxyapatite (HA) or strontium-doped calcium phosphate (SCP) granules, in non-ovariectomised (non-OVX) and ovariectomised (OVX) rats. After 0 (baseline), six and 28d, bone samples were harvested for gene expression analysis, histology and histomorphometry. Tumour necrosis factor-alpha (TNF-alpha), at six days, was higher in the HA, in non-OVX and OVX, whereas interleukin-6 (IL-6), at six and 28d, was higher in SCP, but only in non-OVX. Both materials produced a similar expression of the receptor activator of nuclear factor kappa-B ligand (RANKL). Higher expression of osteoclastic markers, calcitonin receptor (CR) and cathepsin K (CatK), were detected in the HA group, irrespective of non-OVX or OVX. The overall bone formation was comparable between HA and SCP, but with topological differences. The bone area was higher in the defect centre of the HA group, mainly in the OVX, and in the defect periphery of the SCP group, in both non-OVX and OVX. It is concluded that HA and SCP granules result in comparable bone formation in trabecular bone defects. As judged by gene expression and histological analyses, the two materials induced different inflammatory and bone remodelling responses. The modulatory effects are associated with differences in the spatial distribution of the newly formed bone.

  • 45.
    Cardemil, Carina
    et al.
    Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden, Department of Oral and Maxillofacial Surgery, Örebro University Hospital, Örebro, Sweden, BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden .
    Elgali, Ibrahim
    Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden, BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden.
    Xia, Wei
    Applied Materials Science, Department of Engineering Sciences, Uppsala University, Uppsala, Sweden, BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden.
    Emanuelsson, Lena
    Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden, BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden.
    Norlindh, Birgitta
    Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden, BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden.
    Omar, Omar
    Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden, BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden.
    Thomsen, Peter
    Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy at University of Gothenburg, Gothenburg, Sweden, BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, Gothenburg, Sweden .
    Strontium-doped calcium phosphate and hydroxyapatite granules promote different inflammatory and bone remodelling responses in normal and ovariectomised rats2013Inngår i: PLoS ONE, ISSN 1932-6203, E-ISSN 1932-6203, Vol. 8, nr 12, e84932Artikkel i tidsskrift (Fagfellevurdert)
    Abstract [en]

    The healing of bone defects may be hindered by systemic conditions such as osteoporosis. Calcium phosphates, with or without ion substitutions, may provide advantages for bone augmentation. However, the mechanism of bone formation with these materials is unclear. The aim of this study was to evaluate the healing process in bone defects implanted with hydroxyapatite (HA) or strontium-doped calcium phosphate (SCP) granules, in non-ovariectomised (non-OVX) and ovariectomised (OVX) rats. After 0 (baseline), six and 28d, bone samples were harvested for gene expression analysis, histology and histomorphometry. Tumour necrosis factor-α (TNF-α), at six days, was higher in the HA, in non-OVX and OVX, whereas interleukin-6 (IL-6), at six and 28d, was higher in SCP, but only in non-OVX. Both materials produced a similar expression of the receptor activator of nuclear factor kappa-B ligand (RANKL). Higher expression of osteoclastic markers, calcitonin receptor (CR) and cathepsin K (CatK), were detected in the HA group, irrespective of non-OVX or OVX. The overall bone formation was comparable between HA and SCP, but with topological differences. The bone area was higher in the defect centre of the HA group, mainly in the OVX, and in the defect periphery of the SCP group, in both non-OVX and OVX. It is concluded that HA and SCP granules result in comparable bone formation in trabecular bone defects. As judged by gene expression and histological analyses, the two materials induced different inflammatory and bone remodelling responses. The modulatory effects are associated with differences in the spatial distribution of the newly formed bone.

  • 46. Carlsson, C.
    et al.
    Johansson, Carina B.
    Örebro universitet, Institutionen för klinisk medicin.
    Holmgren Peterson, K.
    Sul, Y. T.
    Comparisons of bone tissue formation around pure titanium implants using light- and fluorescence microscopically techniques2006Konferansepaper (Fagfellevurdert)
  • 47.
    Chen, Song
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Glass Ionomer Cements with Improved Bioactive and Antibacterial Properties2016Doktoravhandling, med artikler (Annet vitenskapelig)
    Abstract [en]

    Dental restorative cements are placed in a harsh oral environment where they are subjected to thermal shock, chemical degradation, and repeating masticatory force. The ideal restorative dental cements should have superior mechanical properties, chemical stability, aesthetic, good handling properties, biocompatibility, antibacterial properties, and preferably bioactivity. This thesis presents research on dental restorative cements with enhanced properties. The overall aim was to increase the bioactivity and antibacterial properties of dental restorative cements without affecting their other properties.

    The effect from adding calcium silicate to glass ionomer cement (GIC) was investigated. The results showed that calcium silicate could increase the bioactivity and reduce the cytotoxicity of conventional glass ionomer cement without compromising its setting and mechanical properties.

    Hydroxyapatite (HA) with a high aspect ratio and thin nacreous-layered monetite sheets were also synthesized. Nano HA particles with an aspect ratio of 50 can be synthesized by both precipitation and hydrothermal methods. The aspect ratio was controlled via the pH of reaction medium. Thin nacreous-layered monetite sheets were synthesized through a self-assembly process in the presence of an amine based cationic quaternary surfactant. Temperature, pH, and presence of surfactant played essential roles in forming the nacreous-layered monetite sheets. Then the effect from adding silver doped HA and monetite particles was investigated. The results showed that the antibacterial properties of GIC could be increased by incorporating silver doped HA and monetite particles. Further examination showed that the pH change, F- ion release, and concentration of released Ag+ ions were not responsible for the improved antibacterial properties.

    The quasi-static strengths and compressive fatigue limits of four types of the most commonly used dental restorations were evaluated. In our study, resin modified GIC and resin-based composite showed superior static compressive strength and fatigue limits compared to conventional GIC. The static compressive strength of dental cements increased with the aging time. However, aging had no effect on the compressive fatigue limit of resin modified GIC and resin-based composite. The compressive fatigue limit of conventional GIC even showed a drastic decrease after aging.

  • 48.
    Chen, Song
    et al.
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Pujari-Palmer, Shiuli
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Rubino, Stefano
    Univ Oslo, Dept Phys, Oslo, Norway; Simon Fraser Univ, Dept Chem, Burnaby, BC V5A 1S6, Canada.
    Westlund, Viktoria
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Ott, Marjam
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Engqvist, Håkan
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Xia, Wei
    Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad materialvetenskap.
    Highly repeatable synthesis of nHA with high aspect ratio2015Inngår i: Materials letters (General ed.), ISSN 0167-577X, E-ISSN 1873-4979, Vol. 159, 163-167 s.Artikkel i tidsskrift (Fagfellevurdert)
  • 49.
    Chinga-Carrasco, Gary
    et al.
    RISE, Innventia, PFI – Paper and Fiber Research Institute.
    Kirsebom, H.
    Syverud, Kristin
    RISE, Innventia, PFI – Paper and Fiber Research Institute.
    Designing nanocellulose qualities for wound dressings2013Konferansepaper (Fagfellevurdert)
  • 50.
    Chinga-Carrasco, Gary
    et al.
    RISE, Innventia, PFI – Paper and Fiber Research Institute.
    Powell, L.C
    Tissue Engineering and Reparative Dentistry, Cardiff University School of Dentistry, Cardiff, UK; Centre for NanoHealth, College of Engineering, Swansea University, Swansea, UK..
    Khan, S
    Tissue Engineering and Reparative Dentistry, Cardiff University School of Dentistry, Cardiff, UK..
    Hill, K.E
     Tissue Engineering and Reparative Dentistry, Cardiff University School of Dentistry, Cardiff, UK..
    Thomas, D.W
    Tissue Engineering and Reparative Dentistry, Cardiff University School of Dentistry, Cardiff, UK..
    Wood nanocellulose: Characterization and potential application as barrier against wound bacteria2014Konferansepaper (Fagfellevurdert)
    Abstract [en]

    Wood nanocellulose is a novel biomaterial for wound dressing applications. Wood nanocellulose was produced from never-dried P. radiata pulp fibres. The applied pre-treatment was 2,2,6,6-tetramethylpiperidinyl-1-oxyl  (TEMPO) mediated oxidation. To characterise bacterial growth, P. aeruginosa PAO1 biofilms were grown in Mueller Hinton broth on air-dried films. Various microscopy techniques, including atomic force microscopy (AFM), confocal laser scanning microscopy (CLSM) and field-emission scanning electron microscopy (FESEM), were applied to characterise the nanocellulose material and the bacterial-nanocellulose interactions.   Multiscale assessments, including FESEM and AFM, revealed the effective fibrillation of the fibre wall structure, yielding nanofibrils with diameters less than 20 nm and lengths in the micrometre-scale. Importantly, we have demonstrated that the growth of PAO1 was inhibited in the presence of the nanocellulose suspensions when compared to the control. Additionally, SEM imaging revealed distinct clusters of PAO1 cells growing on the surfaces of nanocellulose films. This work highlights the potential usefulness of novel nanocellulose materials in wound dressings with optimized characteristics.

123456 1 - 50 of 282
RefereraExporteraLink til resultatlisten
Permanent link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf