Change search
Refine search result
1 - 1 of 1
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Rows per page
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sort
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
Select
The maximal number of hits you can export is 250. When you want to export more records please use the 'Create feeds' function.
  • 1.
    Pedral, Jacques
    et al.
    KTH, School of Technology and Health (STH), Medical Engineering, Computer and Electronic Engineering.
    Abriren, Josef
    KTH, School of Technology and Health (STH), Medical Engineering, Computer and Electronic Engineering.
    Analys av lågspänningsfördelning till signalanläggningar2016Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesis
    Abstract [en]

    This report identifies how the system design of low voltage power distribution of the railway can be more cost effective. In the current situation there is a norm on the system design that tends to be replicated each year. This has brought a lack of innovation in the field.

    The purpose of the thesis was to come up with two model stations with the interlocking system M11 respectively M95, where the positioning and nominal size of the UPS:s would be determined to provide a cost effective solution. Furthermore, the cable dimensioning of the model stations was computed as well as the possibility of replacing UPS-systems with rectifier-systems. The model stations were based on two already existing operating sites, Fagersta C (M11) and Skänninge (M95). Lastly, different energy storage alternatives for UPS-systems were compared to acquire the most appropriate choice.

    Through simulations and calculations in, inter alia, the computer program El-Vis, the low voltage power distribution was dimensioned for the model stations. The thesis shows that a distributed UPS-system is preferred in an economical point of view compared to a centralized UPS-system. Furthermore, the thesis establishes that the rectifier system Rectiverter can replace UPS:s. It also states that accumulators are the most suitable alternative for energy storage.

1 - 1 of 1
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf