Change search
Refine search result
1 - 31 of 31
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Rows per page
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sort
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
Select
The maximal number of hits you can export is 250. When you want to export more records please use the 'Create feeds' function.
  • 1.
    Abtahi, Farhad
    et al.
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Berndtsson, Andreas
    Abtahi, Shirin
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Lindecrantz, Kaj
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Development and preliminary evaluation of an Android based heart rate variability biofeedback system2014In: Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE, IEEE conference proceedings, 2014, 3382-3385 p.Conference paper (Refereed)
    Abstract [en]

    The reduced Heart Rate Variability (HRV) is believed to be associated with several diseases such as congestive heart failure, diabetes and chronic kidney diseases (CKD). In these cases, HRV biofeedback may be a potential intervention method to increase HRV which in turn is beneficial to these patients. In this work, a real-time Android biofeedback application based on a Bluetooth enabled ECG and thoracic electrical bioimpedance (respiration) measurement device has been developed. The system performance and usability have been evaluated in a brief study with eight healthy volunteers. The result demonstrates real-time performance of system and positive effects of biofeedback training session by increased HRV and reduced heart rate. Further development of the application and training protocol is ongoing to investigate duration of training session to find an optimum length and interval of biofeedback sessions to use in potential interventions.

  • 2.
    Abtahi, Farhad
    et al.
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Ji, Guangchao
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Lu, Ke
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Rodby, Kristian
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    A knitted garment using intarsia technique for Heart Rate Variability biofeedback: Evaluation of initial prototype2015In: Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE, IEEE , 2015, Vol. 2015, 3121-3124 p.Conference paper (Refereed)
    Abstract [en]

    Heart rate variability (HRV) biofeedback is a method based on paced breathing at specific rate called resonance frequency by giving online feedbacks from user respiration and its effect on HRV. Since the HRV is also influence by different factors like stress and emotions, stress related to an unfamiliar measurement device, cables and skin electrodes may cover the underling effect of such kind of intervention. Wearable systems are usually considered as intuitive solutions which are more familiar to the end-user and can help to improve usability and hence reducing the stress. In this work, a prototype of a knitted garment using intarsia technique is developed and evaluated. Results show the satisfactory level of quality for Electrocardiogram and thoracic electrical bioimpedance i.e. for respiration monitoring as a part of HRV biofeedback system. Using intarsia technique and conductive yarn for making the connection instead of cables will reduce the complexity of fabrication in textile production and hence reduce the final costs in a final commercial product. Further development of garment and Android application is ongoing and usability and efficiency of final prototype will be evaluated in detail.

  • 3.
    Abtahi, Farhad
    et al.
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Lindecrantz, Kaj
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Aslamy, Benjamin
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Boujabir, Imaneh
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    An Affordable ECG and Respiration Monitoring System Based on Raspberry PI and ADAS1000: First Step towards Homecare Applications2015In: 16th Nordic-Baltic Conference on Biomedical Engineering: 16. NBC & 10. MTD 2014 joint conferences. October 14-16, 2014, Gothenburg, Sweden, Springer, 2015, 5-8 p.Conference paper (Refereed)
    Abstract [en]

    Homecare is a potential solution for problems associated with an aging population. This may involve several physiological measurements, and hence a flexible but affordable measurement device is needed. In this work, we have designed an ADAS1000-based four-lead electrocardiogram (ECG) and respiration monitoring system. It has been implemented using Raspberry PI as a platform for homecare applications. ADuM chips based on iCoupler technology have been used to achieve electrical isolation as required by IEC 60601 and IEC 60950 for patient safety. The result proved the potential of Raspberry PI for the design of a compact, affordable, and medically safe measurement device. Further work involves developing a more flexible software for collecting measurements from different devices (measuring, e.g., blood pressure, weight, impedance spectroscopy, blood glucose) through Bluetooth or user input and integrating them into a cloud-based homecare system.

  • 4.
    Abtahi, Farhad
    et al.
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Lindecrantz, Kaj
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Löfgren, Nils
    Elimination of ECG Artefacts in Foetal EEG Using Ensemble Average Subtraction and Wavelet Denoising Methods: A Simulation2014In: XIII Mediterranean Conference on Medical and Biological Engineering and Computing 2013, Springer, 2014, 551-554 p.Conference paper (Refereed)
    Abstract [en]

    Biological signals recorded from surface electrodes contain interference from other signals which are not desired and should be considered as noise. Heart activity is especially present in EEG and EMG recordings as a noise. In this work, two ECG elimination methods are implemented; ensemble average subtraction (EAS) and wavelet denoising methods. Comparison of these methods has been done by use of simulated signals achieved by adding ECG to neonates EEG. The result shows successful elimination of ECG artifacts by using both methods. In general EAS method which remove estimate of all ECG components from signal is more trustable but it is also harder for implementation due to sensitivity to noise. It is also concluded that EAS behaves like a high-pass filter while wavelet denoising method acts as low-pass filter and hence the choice of one method depends on application.

  • 5.
    Atefi, Seyed Reza
    et al.
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS) (Closed 20130701).
    Buendia, Ruben
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS) (Closed 20130701).
    Lindecrantz, Kaj
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS) (Closed 20130701).
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS) (Closed 20130701).
    Cole Function and Conductance-Based Parasitic Capacitance Compensation for Cerebral Electrical Bioimpedance Measurements2012In: Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE, San Diego: IEEE press , 2012, 3368-3371 p.Conference paper (Refereed)
    Abstract [en]

    One of the most common measurement artifacts present in Electrical Bioimpedance Spectroscopy measurements (EBIS) comes from the capacitive leakage effect resulting from parasitic stray capacitances. This artifact produces a deviation in the measured impedance spectrum that is most noticeable at higher frequencies. The artifact taints the spectroscopy measurement increasing the difficulty of producing reliable EBIS measurements at high frequencies. In this work, an approach for removing such capacitive influence from the spectral measurement is presented making use of a novel method to estimate the value of the parasitic capacitance equivalent that causes the measurement artifact. The proposed method has been tested and validated theoretically and experimentally and it gives a more accurate estimation of the value of the parasitic capacitance than the previous methods. Once a reliable value of parasitic capacitance has been estimated the capacitive influence can be easily compensated in the EBIS measured data. Thus enabling analysis of EBIS data at higher frequencies, i.e. in the range of 300-500 kHz like measurements intended for cerebral monitoring, where the characteristic frequency is remarkably higher than EBIS measurements i.e. within the range 30 to 50 kHz, intended for body composition assessment.

  • 6.
    Atefi, Seyed Reza
    et al.
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Lindecrantz, Kaj
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Electrical Bioimpedance cerebral monitoring. Preliminary results from measurements on stroke patients2012In: Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE, IEEE , 2012, 126-129 p.Conference paper (Refereed)
    Abstract [en]

    Electrical Bioimpedance Spectroscopy (EBIS) is currently used in different tissue characterization applications. In this work we aim to use EBIS to study changes in electrical properties of the cerebral tissues after an incident of hemorrhage/ischemic stroke. To do so a case-control study was conducted using six controls and three stroke cases. The preliminary results of this study show that by using Cole-based analysis on EBIS measurements and analyzing the Cole parameters R0 and R∞, it is possible to detect changes on electrical properties of cerebral tissue after stroke. 

  • 7.
    Atefi, Seyed Reza
    et al.
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Lindecrantz, Kaj
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Study of the dynamics of transcephalic cerebral impedance data during cardio-vascular surgery2013In: XV International Conference on Electrical Bio-Impedance (ICEBI) & XIV Conference on Electrical Impedance Tomography (EIT), Institute of Physics (IOP), 2013, Vol. 434, no 1, 012045- p.Conference paper (Refereed)
    Abstract [en]

    Postoperative neurological deficits are one of the risks associated with cardio vascular surgery, necessitating development of new techniques for cerebral monitoring. In this study an experimental observation regarding the dynamics of transcephalic Electrical Bioimpedance (EBI) in patients undergoing cardiac surgery with and without extracorporeal circulation (ECC) was conducted to investigate the potential use of electrical Bioimpedance for cerebral monitoring in cardio vascular surgery. Tetrapolar transcephalic EBI measurements at single frequency of 50 kHz were recorded prior to and during cardio vascular surgery. The obtained results show that the transcephalic impedance decreases in both groups of patients as operation starts, however slight differences in these two groups were also observed with the cerebral impedance reduction in patients having no ECC being less common and not as pronounced as in the ECC group. Changes in the cerebral impedance were in agreement with changes of haematocrit and temperature. The origin of EBI changes is still unexplained however these results encourage us to continue investigating the application of electrical bioimpedance cerebral monitoring clinically.

  • 8.
    Ayllon, David
    et al.
    Department of Signal Theory and Communications.
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Gil-Pita, Roberto
    Department of Signal Theory and Communications.
    Cole equation and parameter estimation from electrical bioimpedance spectroscopy measurements: A comparative study2009In: EMBC: 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, Buenos Aires: IEEE Engineering in Medicine and Biology , 2009, 3779-3782 p.Conference paper (Refereed)
    Abstract [en]

    Since there are several applications of Electrical Bioimpedance (EBI) that use the Cole parameters as base of the analysis, to fit EBI measured data onto the Cole equation is a very common practice within Multifrequency-EBI and spectroscopy. The aim of this paper is to compare different fitting methods for EBI data in order to evaluate their suitability to fit the Cole equation and estimate the Cole parameters. Three of the studied fittings are based on the use of Non-Linear Least Squares on the Cole model, one using the real part only, a second using the imaginary part and the third using the complex impedance. Furthermore, a novel fitting method done on the impedance plane, without using any frequency information has been implemented and included in the comparison. Results show that the four methods perform relatively well but the best fitting in terms of standard error of estimate is the fitting obtained from the resistance only. The results support the possibility of measuring only the resistive part of the bioimpedance to accurately fit Cole equation and estimate the Cole parameters, with entailed advantages.

  • 9. Brown, Shannon
    et al.
    Ortiz-Catalan, Max
    Petersson, Joel
    Rodby, Kristian
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical Engineering, Computer and Electronic Engineering. University of Borås, Sweden.
    Intarsia-Sensorized Band and Textrodes for Real-Time Myoelectric Pattern Recognition2016In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS / [ed] Patton, J Barbieri, R Ji, J Jabbari, E Dokos, S Mukkamala, R Guiraud, D Jovanov, E Dhaher, Y Panescu, D Vangils, M Wheeler, B Dhawan, AP, Institute of Electrical and Electronics Engineers (IEEE), 2016, 6074-6077 p., 7592114Conference paper (Refereed)
    Abstract [en]

    Surface Electromyography (sEMG) has applications in prosthetics, diagnostics and neuromuscular rehabilitation. Self-adhesive Ag/AgCl are the electrodes preferentially used to capture sEMG in short-term studies, however their long-term application is limited. In this study we designed and evaluated a fully integrated smart textile band with electrical connecting tracks knitted with intarsia techniques and knitted textile electrodes. Real-time myoelectric pattern recognition for motor volition and signal-to-noise ratio (SNR) were used to compare its sensing performance versus the conventional Ag-AgCl electrodes. After a comprehending measurement and performance comparison of the sEMG recordings, no significant differences were found between the textile and the Ag-AgCl electrodes in SNR and prediction accuracy obtained from pattern recognition classifiers.

  • 10.
    Brown, Shannon
    et al.
    Högskolan i Borås.
    Ortiz-Catalan, Max
    Chalmers University of Technology.
    Petersson, Joel
    Högskolan i Borås.
    Rödby, Kristian
    Högskolan i Borås.
    Seoane, Fernando
    KTH, School of Technology and Health (STH). Högskolan i Borås, Akademin för vård, arbetsliv och välfärd.
    Intarsia-sensorized band and textrodes for real-time myoelectric pattern recognition2016In: Engineering in Medicine and Biology Society (EMBC), 2016 IEEE 38th Annual International Conference of the, Institute of Electrical and Electronics Engineers (IEEE), 2016, 6074-6077 p.Conference paper (Refereed)
  • 11.
    Buendia, Ruben
    et al.
    School of Engineering, University of Borås.
    Gil-Pita, Roberto
    Department of Theory of the Signal and Communications, University of Alcala, Madrid, Spain.
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Cole parameter estimation from total right side electrical bioimpedance spectroscopy measurements: Influence of the number of frequencies and the upper limit2011In: 2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, 1843-1846 p.Conference paper (Refereed)
    Abstract [en]

    Applications based on measurements of Electrical Bioimpedance Spectroscopy (EBIS) analysis are proliferating. The most spread and known application of EBIS is the non-invasive assessment of body composition. Fitting to the Cole function to obtain the Cole parameters, R<sub>0</sub> and R<sub>&#x221E;</sub>, is the core of the EBIS analysis to obtain the body fluid distribution. An accurate estimation of the Cole parameters is essential for the Body Composition Assessment (BCA) and the estimation process depends on several factors. One of them is the upper frequency limit used for the estimation and the other is the number of measured frequencies in the measurement frequency range. Both of them impose requirements on the measurement hardware, influencing largely in the complexity of the bioimpedance spectrometer. In this work an analysis of the error obtained when estimating the Cole parameters with several frequency ranges and different number of frequencies has been performed. The study has been done on synthetic EBIS data obtained from experimental Total Right Side (TRS) measurements. The results suggest that accurate estimations of R<sub>0</sub> and R<sub>&#x221E;</sub> for BCA measurements can be achieved using much narrower frequency ranges and quite fewer frequencies than electrical bioimpedance spectrometers commercially available nowadays do.

  • 12.
    Buendia, Ruben
    et al.
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Harris, Matthew
    Phillips Research.
    Caffarel, Jeniffer
    Phillips Research.
    Gil-Pita, Roberto
    Department of Theory of the Signal and Communications, University of Alcala, Madrid, Spain.
    Hook Effect correction & resistance-based Cole fitting prior Cole model-based analysis: Experimental validation2010In: Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2010, IEEE Engineering in Medicine and Biology , 2010, 6563-6566 p.Conference paper (Refereed)
    Abstract [en]

    The analysis of measurements of Electrical Bioimpedance (EBI) is on the increase for performing non-invasive assessment of health status and monitoring of pathophysiological mechanisms. EBI measurements might contain measurements artefacts that must be carefully removed prior to any further analysis. Cole model-based analysis is often selected when analysing EBI data and might lead to miss-conclusion if it is applied on data contaminated with measurement artefacts. The recently proposed Correction Function to eliminate the influence of the Hook Effect from EBI data and the fitting to the real part of the Cole model to extract the Cole parameters have been validated on experimental measurements. The obtained results confirm the feasible experimental use of these promising pre-processing tools that might improve the outcome of EBI applications using Cole model-based analysis.

  • 13.
    Cuba-Gyllensten, Illapha
    et al.
    KTH, School of Technology and Health (STH). Philips Research Europe, High Tech. Campus 34, 5656AE, Eindhoven, Netherlands; ACTLab., Signal Processing Systems, TU Eindhoven, 5600MB Eindhoven, Netherlands.
    Abtahi, Farhad
    Philips Research Europe, High Tech. Campus 34, 5656AE, Eindhoven, Netherlands.
    Bonomi, Alberto G.
    KTH, School of Technology and Health (STH).
    Lindecrantz, Kaj
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems. University of Borås, Sweden.
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems. Karolinska Institute, Sweden.
    Amft, O.
    ACTLab., Signal Processing Systems, TU Eindhoven, 5600MB Eindhoven, Netherlands.
    Removing respiratory artefacts from transthoracic bioimpedance spectroscopy measurements2013In: XV International Conference on Electrical Bio-Impedance (ICEBI) & XIV Conference on Electrical Impedance Tomography (EIT), Institute of Physics Publishing (IOPP), 2013, Vol. 434, no 1Conference paper (Refereed)
    Abstract [en]

    Transthoracic impedance spectroscopy (TIS) measurements from wearable textile electrodes provide a tool to remotely and non-invasively monitor patient health. However, breathing and cardiac processes inevitably affect TIS measurements, since they are sensitive to changes in geometry and air or fluid volumes in the thorax. This study aimed at investigating the effect of respiration on Cole parameters extracted from TIS measurements and developing a method to suppress artifacts. TIS data were collected from 10 participants at 16 frequencies (range: 10 kHz - 1 MHz) using a textile electrode system (Philips Technologie Gmbh). Simultaneously, breathing volumes and frequency were logged using an electronic spirometer augmented with data from a breathing belt. The effect of respiration on TIS measurements was studied at paced (10 and 16 bpm) deep and shallow breathing. These measurements were repeated for each subject in three different postures (lying down, reclining and sitting). Cole parameter estimation was improved by assessing the tidal expiration point thus removing breathing artifacts. This leads to lower intra-subject variability between sessions and a need for less measurements points to accurately assess the spectra. Future work should explore algorithmic artifacts compensation models using breathing and posture or patient contextual information to improve ambulatory transthoracic impedance measurements.

  • 14. Cunico, F. J.
    et al.
    Marquez, Juan Carlos
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Hilke, H.
    Skrifvars, M.
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Studying the performance of conductive polymer films as textile electrodes for electrical bioimpedance measurements2013In: XV International Conference on Electrical Bio-Impedance (ICEBI) & XIV Conference on Electrical Impedance Tomography (EIT), 2013, Vol. 434, no 1, 012027- p.Conference paper (Refereed)
    Abstract [en]

    With the goal of finding novel biocompatible materials suitable to replace silver in the manufacturing of textile electrodes for medical applications of electrical bioimpedance spectroscopy, three different polymeric materials have been investigated. Films have been prepared from different polymeric materials and custom bracelets have been confectioned with them. Tetrapolar total right side electrical bioimpedance spectroscopy (EBIS) measurements have been performed with polymer and with standard gel electrodes. The performance of the polymer films was compared against the performance of the gel electrodes. The results indicated that only the polypropylene 1380 could produce EBIS measurements but remarkably tainted with high frequency artefacts. The influence of the electrode mismatch, stray capacitances and large electrode polarization impedance are unclear and they need to be clarified with further studies. If sensorized garments could be made with such biocompatible polymeric materials the burden of considering textrodes class III devices could be avoided.

  • 15. Ferreira, J.
    et al.
    Seoane, Fernando
    School of Engineering, University of Borås, Borås 501 90, Sweden .
    Lindecrantz, Kaj
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Portable bioimpedance monitor evaluation for continuous impedance measurements: Towards wearable plethysmography applications2013In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 2013, 559-562 p.Conference paper (Refereed)
    Abstract [en]

    Personalised Health Systems (PHS) that could benefit the life quality of the patients as well as decreasing the health care costs for society among other factors are arisen. The purpose of this paper is to study the capabilities of the System-on-Chip Impedance Network Analyser AD5933 performing high speed single frequency continuous bioimpedance measurements. From a theoretical analysis, the minimum continuous impedance estimation time was determined, and the AD5933 with a custom 4-Electrode Analog Front-End (AFE) was used to experimentally determine the maximum continuous impedance estimation frequency as well as the system impedance estimation error when measuring a 2R1C electrical circuit model. Transthoracic Electrical Bioimpedance (TEB) measurements in a healthy subject were obtained using 3M gel electrodes in a tetrapolar lateral spot electrode configuration. The obtained TEB raw signal was filtered in MATLAB to obtain the respiration and cardiogenic signals, and from the cardiogenic signal the impedance derivative signal (dZ/dt) was also calculated. The results have shown that the maximum continuous impedance estimation rate was approximately 550 measurements per second with a magnitude estimation error below 1% on 2R1C-parallel bridge measurements. The displayed respiration and cardiac signals exhibited good performance, and they could be used to obtain valuable information in some plethysmography monitoring applications. The obtained results suggest that the AD5933-based monitor could be used for the implementation of a portable and wearable Bioimpedance plethysmograph that could be used in applications such as Impedance Cardiography. These results combined with the research done in functional garments and textile electrodes might enable the implementation of PHS applications in a relatively short time from now.

  • 16.
    Ferreira, Javier
    et al.
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Lindecrantz, Kaj
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    AD5933-based electrical bioimpedance spectrometer: Towards textile-enabled applications2011In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 2011, Vol. 2011, 3282-3285 p.Conference paper (Refereed)
    Abstract [en]

    Advances on System-On-Chip and Textile technology allows the development of Textile-enabled measurement instrumentation. Textile Electrodes (Textrodes) have been proven reliable for performing Electrical Bioimpedance Spectroscopy (EBIS) measurements, and the availability of a integrated circuit impedance spectrometer, the AD5933, has allowed the implementation of small size EBIS spectrometers. In this work an AD5933-based spectrometer has been implemented, and its performance on 2R1C circuits and for tetrapolar total right side EBIS measurements has been compared against the commercially available spectrometer SFB7. The study has been focused on the working upper frequency range and the estimation of the Cole parameters required for assessment of body fluid distribution: R(0) and R(∞). The results indicate that AD5933-based spectrometer implemented in this work can perform accurate impedance measurements well above the upper limits recommended in the datasheet. The AD5933-EBIS presents a good performance compared with the SFB7 on the 2R1C circuit and the total right side measurements, showing a smaller error in the resistance spectrum and small deviation error in the reactance when measuring over 270 kHz. The comparison on the Cole parameters estimation obtained with the SFB7 and the AD5933-based spectrometer exhibit a difference below 1% for the estimation of R(0) and R(∞). Consequently the overall measurement performance shown by the implemented AD5933-based spectrometer suggests its feasible use for EBIS measurements using dry Textrodes. This is of special relevance for the proliferation of EBI-based personalized health monitoring systems for patients that require to monitor the distribution of body fluids, like in dialysis.

  • 17.
    Ferreira, Javier
    et al.
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Álvarez, L.
    Buendía, R.
    Ayllón, D.
    Llerena, C.
    Gil-Pita, R.
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Bioimpedance-based wearable measurement instrumentation for studying the autonomic nerve system response to stressful working conditions2013In: XV International Conference on Electrical Bio-Impedance (ICEBI) & XIV Conference on Electrical Impedance Tomography (EIT), 2013, Vol. 434, no 1, 012015- p.Conference paper (Refereed)
    Abstract [en]

    The assessment of mental stress on workers under hard and stressful conditions is critical to identify which workers are not ready to undertake a mission that might put in risk their own life and the life of others. The ATREC project aims to enable Real Time Assessment of Mental Stress of the Spanish Armed Forces during military activities. Integrating sensors with garments and using wearable measurement devices, the following physiological measurements were recorded: heart and respiration rate, skin galvanic response as well as peripheral temperature. The measuring garments are the following: a sensorized glove, an upper-arm strap and a repositionable textrode chest strap system with 6 textrodes. The implemented textile-enabled instrumentation contains: one skin galvanometer, two temperature sensors, for skin and environmental, and an Impedance Cardiographer/Pneumographer containing a 1 channel ECG amplifier to record cardiogenic biopotentials. The implemented wearable systems operated accordingly to the specifications and are ready to be used for the mental stress experiments that will be executed in the coming phases of the project in healthy volunteers.

  • 18.
    Marquez, Juan Carlos
    et al.
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Ferreira, Javier
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Buendia, Ruben
    Lindecrantz, Kaj
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Textile electrode straps for wrist-to-ankle bioimpedance measurements for Body Composition Analysis: Initial validation & experimental results2010In: 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), IEEE Engineering in Medicine and Biology Society , 2010, 6385-6388 p.Conference paper (Refereed)
    Abstract [en]

    Electrical Bioimpedance (EBI) is one of the non-invasive monitoring technologies that could benefit from the emerging textile based measurement systems. If reliable and reproducible EBI measurements could be done with textile electrodes, that would facilitate the utilization of EBI-based personalized healthcare monitoring applications. In this work the performance of a custom-made dry-textile electrode prototype is tested. Four-electrodes ankle-to-wrist EBI measurements have been taken on healthy subjects with the Impedimed spectrometer SFB7 in the frequency range 5 kHz to 1 MHz. The EBI spectroscopy measurements taken with dry electrodes were analyzed via the Cole and Body Composition Analysis (BCA) parameters, which were compared with EBI measurements obtained with standard electrolytic electrodes. The analysis of the obtained results indicate that even when dry textile electrodes may be used for EBI spectroscopy measurements, the measurements present remarkable differences that influence in the Cole parameter estimation process and in the final production of the BCA parameters. These initial results indicate that more research work must be done to in order to obtain a textile-based electrode that ensures reliable and reproducible EBI spectroscopy measurements.

  • 19.
    Marquez, Juan Carlos
    et al.
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Lindecrantz, Kaj
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Skin-electrode contact area in electrical bioimpedance spectroscopy. Influence in total body composition assessment2011In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, IEEE Engineering In Medicine and Biology Society , 2011, Vol. 2011, 1867-1870 p.Conference paper (Refereed)
    Abstract [en]

    Electrical Bioimpedance Spectroscopy (EBIS) has been widely used for assessment of total body composition and fluid distribution. (EBIS) measurements are commonly performed with electrolytic electrodes placed on the wrist and the ankle with a rather small skin-electrode contact area. The use of textile garments for EBI requires the integration of textrodes with a larger contact area surrounding the limbs in order to compensate the absence of electrolytic medium commonly present in traditional Ag/AgCl gel electrodes. Recently it has been shown that mismatch between the measurements electrodes might cause alterations on the EBIS measurements. When performing EBIS measurements with textrodes certain differences have been observed, especially at high frequencies, respect the same EBIS measurements using Ag/AgCl electrodes. In this work the influence of increasing the skin-electrode area on the estimation of body composition parameters has been studied performing experimental EBIS measurement. The results indicate that an increment on the area of the skin-electrode interface produced noticeable changes in the bioimpedance spectra as well as in the body composition parameters. Moreover, the area increment showed also an apparent reduction of electrode impedance mismatch effects. This influence must be taken into consideration when designing and testing textile-enable EBIS measurement systems.

  • 20. Marquez, Juan Carlos
    et al.
    Seoane, Fernando
    Välimäki, Elina
    University of Borås.
    Lindecrantz, Kaj
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Comparison of dry-textile electrodes for electrical bioimpedance spectroscopy measurements2010Conference paper (Refereed)
    Abstract [en]

    Textile Electrodes have been widely studied for biopotentials recordings, specially for monitoring the cardiac activity. Commercially available applications, such as Adistar T-shirt and Textronics Cardioshirt, have proved a good performance for heart rate monitoring and are available worldwide. Textile technology can also be used for Electrical Bioimpedance Spectroscopy measurements enabling home and personalized health monitoring applications however solid ground research about the measurement performance of the electrodes must be done prior to the development of any textile-enabled EBI application. In this work a comparison of the measurement performance of two different types of dry-textile electrodes and manufacturers has been performed against standardized RedDot 3M Ag/AgCl electrolytic electrodes. 4-Electrode, whole body, Ankle-to-Wrist EBI measurements have been taken with the Impedimed spectrometer SFB7 from healthy subjects in the frequency range of 3kHz to 500kHz. Measurements have been taken with dry electrodes at different times to study the influence of the interaction skin-electrode interface on the EBI measurements. The analysis of the obtained complex EBI spectra shows that the measurements performed with textile electrodes produce constant and reliable EBI spectra. Certain deviation can be observed at higher frequencies and the measurements obtained with Textronics and Ag/AgCl electrodes present a better resemblance. Textile technology, if successfully integrated it, may enable the performance of EBI measurements in new scenarios allowing the rising of novel wearable monitoring applications for home and personal care as well as car safety.

  • 21.
    Pau, Ivan
    et al.
    Universidad Politecnica de Madrid.
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS) (Closed 20130701).
    Lindecrantz, Kaj
    Valero, Miguel Angel
    Universidad Politecnica de Madrid.
    Carracedo, Justo
    Universidad Politecnica de Madrid.
    Home e-health system integration in the Smart Home through a common media server.2009In: EMBC: 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, Vol. 2009, 6171-6174 p.Conference paper (Refereed)
    Abstract [en]

    Home e-health systems and services are revealed as one of the most important challenges to promote Quality of Life related to Health in the Information Society. Leading companies have worked on e-health systems although the majority of them are addressed to hospital or primary care settings. The solution detailed in this paper offers a personal health system to be integrated with Smart Home services platform to support home based e-care. Thus, the home e-health system and architecture detailed in this research work is ready to supply a seamless personal care solution both from the biomedical data analysis, service provision, security guarantee and information management s point of view. The solution is ready to be integrated within the Accessible Digital Home, a living lab managed by Universidad Politécnica de Madrid for R&D activities.

  • 22.
    Seoane, Fernando
    et al.
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems. University of Boras, Sweden.
    Abtahi, Shirin
    Abtahi, Farhad
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems. Karolinska Institute, Sweden.
    Ellegard, L.
    Johannsson, G.
    Bosaeus, I.
    Ward, L C
    Slightly superior performance of bioimpedance spectroscopy over single frequency regression equations for assessment of total body water2015In: Engineering in Medicine and Biology Society (EMBC), 2015 37th Annual International Conference of the IEEE, IEEE conference proceedings, 2015, 3707-3710 p.Conference paper (Refereed)
    Abstract [en]

    Electrical bioimpedance has been used for several decades to assess body fluid distribution and body composition by using single frequency and bioimpedance spectroscopic (BIS) techniques. It remains uncertain whether BIS methods have better performance compare to single frequency regression equations. In this work the performance of two BIS methods and four different 50 kHz single frequency prediction equations was studied in a data set of wrist-to-ankle tetrapolar BIS measurements (5-1000 kHz) together with reference values of total body water obtained by tritium dilution in 92 patients. Data were compared using regression techniques and BlandAltman plots. The results of this study showed that all methods produced similarly high correlation and concordance coefficients, indicating good accuracy as a method. Limits of agreement analysis indicated that the population level performance of Sun’s prediction equations was very similar to the performance of both BIS methods. However, BIS methods in practice have slightly better predictive performance than the single-frequency equations as judged by higher correlation and the limits of agreement from the Bland-Altman analysis. In any case, the authors believe that an accurate evaluation of performance of the methods cannot be done as long as the evaluation is done using Bland-Altman analysis, the commonly accepted technique for this kind of performance comparisons.

  • 23.
    Seoane, Fernando
    et al.
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS) (Closed 20130701).
    Bragós, Ramon
    Technical University of Catalonia.
    Lindecrantz, Kaj
    Current Source for Wideband Electrical Bioimpedance Spectroscopy Based on a Single Operational Amplifier2006In: WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6 / [ed] Kim, SI; Suh, TS, 2006, 707-710 p.Conference paper (Refereed)
    Abstract [en]

    Traditionally, measurements of electrical bioimpedance for medical diagnostic purposes have used only low frequencies, usually below 100 kHz. The analysis focused only on the resistive part of the impedance; very often at low frequencies the reactive part of the impedance is negligible. Recent studies of the electrical bioimpedance spectrum, both real and imaginary parts, have indicated new potential applications e.g. detection of meningitis, skin cancer assessment and brain cellular edema detection. An important functional unit in a wideband impedance spectrometer is the current source used to inject the current into the tissue under study. A current source must provide an output current virtually constant over the frequency range of interest and independent of the load at the output. Several designs have been proposed over the years but the performance of them all degraded markedly near bellow 1 MHz e.g. Ackmann in 1993, Bragos et al in 1994 and Bertemes-Filho et al in 2000. The development of electronic technology has made available devices that allow us to obtain a current source with large output impedance, larger than 100 k Omega, above I MHz and based in a simple single Op-Amp circuit topology. Simulation results and experimental measurements are compared and the most important parameters of the VCCS are analytically studied and experimentally tested, including the dependency to changes in the circuit elements and the incidence of the Op-Amp parameters on the current source features.

  • 24.
    Seoane, Fernando
    et al.
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Buendia, Ruben
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Gil-Pita, Roberto
    Department of Theory of the Signal and Communications, University of Alcala, Madrid, Spain.
    Cole parameter estimation from electrical bioconductance spectroscopy measurements2010In: 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), IEEE Press, 2010, Vol. 2010, 3495-3498 p.Conference paper (Refereed)
    Abstract [en]

    Several applications of Electrical Bioimpedance (EBI) make use of Cole parameters as base of their analysis, therefore Cole parameters estimation has become a very common practice within Multifrequency- and EBI spectroscopy. EBI measurements are very often contaminated with the influence of parasitic capacitances, which contributes to cause a hook-alike measurement artifact at high frequencies in the EBI obtained data. Such measurement artifacts might cause wrong estimations of the Cole parameters, contaminating the whole analysis process and leading to wrong conclusions. In this work, a new approach to estimate the Cole parameters from the real part of the admittance, i.e. the conductance, is presented and its performance is compared with the results produced with the traditional fitting of complex impedance to a depressed semi-circle. The obtained results prove that is feasible to obtain the full Cole equation from only the conductance data and also that the estimation process is safe from the influence capacitive leakage.

  • 25.
    Seoane, Fernando
    et al.
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Ferreira, Javier
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Buendia, Ruben
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Lindecrantz, Kaj
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Adaptive frequency distribution for Electrical Bioimpedance Spectroscopy measurements2012In: Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE, IEEE , 2012, 562-565 p.Conference paper (Refereed)
    Abstract [en]

    This paper presents a novel frequency distribution scheme intended to provide more accurate estimations of Cole parameters. Nowadays a logarithmic frequency distribution is mostly used in Electrical Bioimpedance Spectroscopy (EBIS) applications. However it is not optimized following any criterion. Our hypothesis is that an EBIS signal contains more information where the variation of the measurement regarding the frequency is larger; and that there ought to be more measuring frequencies where there is more information. Results show that for EBIS data with characteristic frequencies up to 200 kHz the error obtained with both frequency distribution schemes is similar. However, for EBIS data with higher values of characteristic frequency the error produced when estimating the values from EBIS measurements using an adaptive frequency distribution is smaller. Thus it may useful for EBIS applications with high values of characteristic frequency, e.g. cerebral bioimpedance.

  • 26.
    Seoane, Fernando
    et al.
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Ferreira, Javier
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Marquez, Juan Carlos
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Skrifvars, Mikael
    University of Borås.
    Conductive Polymer Films as Textrodes for Biopotential Sensing2011Conference paper (Other academic)
    Abstract [en]

    Introduction: After several years of progresses in textile technology and wearable measurement instrumentation, applications of wearable textile-electronics systems are arising providing a stable background for commercial applications. So far, the available commercial solutions are centered on fitness applications and mostly based in the acquisition of heart rate through Textile Electrodes (Textrodes) based on metallic threads or on conductive rubber compounds. Methods and Materials: In this work a novel material approach is presented to produce Textrodes for acquisition of Electrocardiographic (ECG) signals using a conductive polypropylene (PP1386 from Premix, Finland) polymer material. The polymer was film extruded into thin films, and used as such in the Textrode. Conductive Polymer Films (CPF) have been used to produce Textrodes, and its measurement performance has been compared with the ECG signals obtained with commercial Textrode fabrics and conventional Ag/AgCl electrodes. In order to set up the same measurement conditions, a chest strap tailored to host the testing electrodes has been used. Results: The close resemblance of the ECG acquired with the textile fabric electrodes, the Ag/AgCl electrodes and the PP1386 CPF electrodes suggest that the Polymer Electrodes PP1386 are a feasible alternative to the current textile fabrics that use silver thread as conductive material and also to conductive rubber material. Discussion & Conclusion: The availability of the Conductive Polymer Electrode PP1386 in a film form allows the manufacturing of electrodes by conventional textile processes, like lamination or sewing, therefore facilitating the transition from lab prototyping to industrial manufacturing. Replacing the traditional silver thread as conductive element in the fabrication of Textrodes will definitely reduce the material cost per Textrode. Biocompatibility issues and manufacturability issues must be addressed but the exhibited functional performance is showing encouraging results.

  • 27.
    Seoane, Fernando
    et al.
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS) (Closed 20130701).
    Lindecrantz, Kaj
    Influence of the Skull and the Scalp on the Electrical Impedance of the Head and the Implications on Detection of Brain Cellular Edema2005In: IFMBE proceedings of the 12th International Conference on Biomedical Engineering, Singapore: Springer , 2005Conference paper (Refereed)
  • 28.
    Seoane, Fernando
    et al.
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Rempfer, Markus
    University of Borås.
    Marquez, Juan Carlos
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Lindecrantz, Kaj
    KTH, School of Technology and Health (STH), Medical sensors, signals and systems (MSSS).
    Textile-enabled Instrumentation for Impedance Cardiographic Signals2011Conference paper (Other academic)
  • 29.
    Vega-Barbas, Mario
    et al.
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Pau, Ivan
    Univerisdad Politecnica de Madrid.
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Confidence: dependencies and their critical role in fostering user acceptance in pervasive applications2014Conference paper (Refereed)
    Abstract [en]

    Pervasive computing offers new scenarios where users are surrounded by invisible and proactive technology making smart spaces. Although the utility and power of solutions developed using this computer paradigm are proved, there are unresolved problems that hinder their acceptance and inclusion in our private life. Users have problems understanding the operations of a pervasive computing solution, and therefore they should trust that the solution works properly and according to their expectations. Nevertheless, the concept of trust is already framed in a specific use within the ecosystem of applications that can populate a smart space. To take this concept of trust to the whole space, we propose to study and define the concept of confidence. In contrast to the concept of trust, confidence has deeper psychological implications.

  • 30.
    Xie, Li
    et al.
    KTH, School of Information and Communication Technology (ICT), Electronic Systems. KTH, School of Information and Communication Technology (ICT), Centres, VinnExcellence Center for Intelligence in Paper and Packaging, iPACK.
    Yang, Geng
    KTH, School of Information and Communication Technology (ICT), Electronic Systems. KTH, School of Information and Communication Technology (ICT), Centres, VinnExcellence Center for Intelligence in Paper and Packaging, iPACK.
    Xu, Linlin
    KTH, School of Information and Communication Technology (ICT), Centres, VinnExcellence Center for Intelligence in Paper and Packaging, iPACK.
    Seoane, Fernando
    KTH, School of Technology and Health (STH), Medical Engineering, Medical sensors, signals and systems.
    Chen, Qiang
    KTH, School of Information and Communication Technology (ICT), Electronic Systems. KTH, School of Information and Communication Technology (ICT), Centres, VinnExcellence Center for Intelligence in Paper and Packaging, iPACK.
    Zheng, Lirong
    KTH, School of Information and Communication Technology (ICT), Electronic Systems. KTH, School of Information and Communication Technology (ICT), Centres, VinnExcellence Center for Intelligence in Paper and Packaging, iPACK. State Key Laboratory of ASICs and Systems, Fudan University, 200433, Shanghai, China .
    Characterization of dry biopotential electrodes2013In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS, 2013, 1478-1481 p.Conference paper (Refereed)
    Abstract [en]

    Driven by the increased interest in wearable long-term healthcare monitoring systems, varieties of dry electrodes are proposed based on different materials with different patterns and structures. Most of the studies reported in the literature focus on proposing new electrodes and comparing its performance with commercial electrodes. Few papers are about detailed comparison among different dry electrodes. In this paper, printed metal-plate electrodes, textile based electrodes, and spiked electrodes are for the first time evaluated and compared under the same experimental setup. The contact impedance and noise characterization are measured. The in-vivo electrocardiogram (ECG) measurement is applied to evaluate the overall performance of different electrodes. Textile electrodes and printed electrodes gain comparable high-quality ECG signals. The ECG signal obtained by spiked electrodes is noisier. However, a clear ECG envelope can be observed and the signal quality can be easily improved by backend signal processing. The features of each type of electrodes are analyzed and the suitable application scenario is addressed.

  • 31.
    Zhang, Rui
    et al.
    University of Passau.
    Freund, Martin
    University of Passau.
    Amft, Oliver
    University of Passau.
    Cheng, Jingyuan
    DFKI.
    Zhou, Bo
    DFKI.
    Lukowicz, Paul
    DFKI.
    Seoane, Fernando
    KTH, School of Technology and Health (STH). Högskolan i Borås, Akademin för vård, arbetsliv och välfärd.
    Chabrecek, Peter
    Sefar AG.
    A generic sensor fabric for multi-modal swallowing sensing in regular upper-body shirts2016In: Proceedings of the 2016 ACM International Symposium on Wearable Computers, ACM Digital Library, 2016, 46-47 p.Conference paper (Refereed)
    Abstract [en]

    We investigate a generic fabric material as basis for resistive pressure and bio-impedance sensors and apply the fabric in a shirt collar for swallowing spotting. A pilot study confirmed the signal performance of both sensor types.

1 - 31 of 31
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf