Change search
ReferencesLink to record
Permanent link

Direct link
Installation effects and self diagnostics for ultrasonic flow measurement
2001 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

In the district heating industry, heat meters, consisting among other things of a flow meter, are used for billing purpose. The district heating industry desires accurate and low cost flow measurements. There are mainly two reasons. An under estimation of the flow rate leads to a loss of income for the district heating industry. Further, the total cost for measuring, including the cost for the heat meter, the reading and the maintenance, represents a relatively large part of the total energy cost. Therefore a project concerning measurement quality assurance in district heating systems is in progress at Luleå University of Technology. As a part of this project the possibility of self diagnostic techniques for flow meters is investigated. It is well known that installation effects greatly impair the flow measurement involved in heat metering. Thus this thesis focus on self diagnostics of different installation effects. The basic assumption is that the flow meter noise level is correlated to turbulence intensity. Since the turbulence intensity is effected by installation effects, the noise level can be used to detect conditions for which the flow meter shows erroneous results. In district heating applications the use of ultrasonic flow meters are becoming more and more frequent. The self diagnostic approach has therefore been investigated for a small size prototype ultrasonic flow meter. Single and double elbow pipe bends and pipe diameter reductions mounted in front of the meter and pulsating flow give rise to small but reproducible errors. The magnitude of the maximum errors were in the range of 2 to 4% of flow rate. At low flow rates with pulsating flow the errors were larger. Also small commercial ultrasonic flow meters were investigated. These commercial meters are commonly used in heat meters in small district heating subscriber stations. The results demonstrate that both temperature changes and installation effects introduce errors in the flow measurements. By studying the noise level of the signal from the prototype ultrasonic flow meter it is clear that all installation effects tested caused a clear increase in the flow signal noise level. It is clear that no tested disturbance causing measurement errors, larger than 1% of the flow rate, will pass undetected. Neither will normal conditions with a varying flow rate or single measurement outliers cause false alarms. It is anticipated that this increase in the future can be detected on-line by the flow meter itself giving it a self diagnostic capability.

Place, publisher, year, edition, pages
Luleå: Luleå tekniska universitet, 2001. , 86 p.
Series
Doctoral thesis / Luleå University of Technology 1 jan 1997 → …, ISSN 1402-1544 ; 2001:11
Research subject
Industrial Electronics
Identifiers
URN: urn:nbn:se:ltu:diva-17954Local ID: 607a0f70-74e0-11db-962b-000ea68e967bOAI: oai:DiVA.org:ltu-17954DiVA: diva2:990960
Note
Godkänd; 2001; 20061115 (haneit)Available from: 2016-09-29 Created: 2016-09-29Bibliographically approved

Open Access in DiVA

fulltext(56839 kB)2 downloads
File information
File name FULLTEXT01.pdfFile size 56839 kBChecksum SHA-512
96fff8dd189222f034246850cf9d2f540c5455cf232e1d0b544103f8cdae1f44d555f5a1ffeba258d7a69ec2a12505020a585767dd1fda26de8f03571a156a4b
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Carlander, Carl

Search outside of DiVA

GoogleGoogle Scholar
Total: 2 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 28 hits
ReferencesLink to record
Permanent link

Direct link