Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Structural and Construction Engineering.
2005 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

Rehabilitation and strengthening of concrete structures with externally bonded FRP (Fibre Reinforced Polymers) has been a viable technique for at least a decade. The most common way to strengthen a structure is in flexure where thedesign normally follows traditional concrete design, with exceptions for control of bond and anchorage related to the FRP. The method is also used for strengthening in shear and torsion, as well as for strengthening of columns. An interesting and useful application is strengthening of slabs or walls without or with openings. In the latter situation, FRP sheets or plates are very suitable; not only because of their strength, but also due to the simplicity in theexecution in comparison to traditional steel girders or other lintel systems. Even though many benefits have been shown in the use of FRP strengthening of openings in practical applications, not much research have been presented in the scientific literature. In this licentiate thesis, the results from laboratory tests on strengthened slabs loaded with a uniformly distributed load are analyzed with analytical and numerical methods. The slabs with openings have been strengthened with CFRP (Carbon Fibre Reinforced Polymers) sheets and are compared to traditionally steel reinforced slabs, both with and without openings. The results from the tests show that slabs with openings can be strengthened with externally bonded CFRP sheets. The performance is, in comparison, even better than for traditionally steel reinforced slabs if bond failure can be avoided. The numerical and analytical evaluations are in good agreement with the experimental results. The case study presented in chapter 5, shows a practical design application of a courtyard deck strengthened with CFRP using epoxy bonded plates. It also points out the difficulties in retrofitting of existing structures. Since the information was inadequate when the original design was performed, an active design approach was used i.e. the design was changed when the true site conditions was revealed during the reconstruction work.

Place, publisher, year, edition, pages
Luleå: Luleå tekniska universitet, 2005. , 154 p.
Series
Licentiate thesis / Luleå University of Technology, ISSN 1402-1757 ; 2005:87
Research subject
Structural Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-17854Local ID: 5888b4c0-8aa6-11db-8975-000ea68e967bOAI: oai:DiVA.org:ltu-17854DiVA: diva2:990860
Note
Godkänd; 2005; 20061213 (haneit)Available from: 2016-09-29 Created: 2016-09-29Bibliographically approved

Open Access in DiVA

fulltext(18040 kB)2 downloads
File information
File name FULLTEXT01.pdfFile size 18040 kBChecksum SHA-512
79211ac1b773cc6916807e3234118bd390c0e33fb4bd8ceeb6906ad0f89618df515e6c8be21f169347648380705c0349fb84e0db139d51ffebf3206f20576224
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Enochsson, Ola
By organisation
Structural and Construction Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 2 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 2 hits
ReferencesLink to record
Permanent link

Direct link