Fibre reinforced polymers in civil engineering: flexural strengthening of concrete structures with prestressed near surface mounted CFRP rods
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Structural and Construction Engineering.
2003 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

Repair and/or upgrading of concrete structures with bonded steel or FRP (Fiber Reinforced Polymers) materials or by use of external tendons have been used for some time. In most cases the bonded on FRP materials are unstressed. However if prestressing could be applied better utilization of the strengthening material and a better strengthening result would most likely be achieved. More research is carried out in the area of repair and upgrading of concrete structures with prestressed FRP materials. Bonding prestressed FRP laminates or sheets to a concrete surface has proven to be efficient and also gives a better utilization of the strengthening material used. External prestressed cables of FRP materials have shown to be an alternative to steel cables in, for example, upgrading concrete structures. Good durability properties and a first-rate behaviour in creep and relaxation have given very good results so far. One weak part for both external prestressed cables as well as bonded laminates has shown to be anchorage. For cables this is due to lower lateral properties of the cables compared to the axial properties and for laminates due to the high peeling stresses at the cut off end of the laminate. Often the anchorage device has problem to handle the high stresses that would justify the use of FRP materials in prestressing, i.e. the stress that can be achieved due to the anchorage is not high enough. However this is changing with a number of research projects around the world focusing on the anchorage issue where a number of anchorage details have been developed The research presented in this thesis is focused on strengthening concrete structures with prestressed CFRP rods bonded in slots in the concrete cover. The prestressing force was transferred to the concrete via adhesive bond only; no mechanical anchorage was used during the tests. Three factors were varied during the tests; prestressing force, bond length (i.e. length of the rod) and stiffness of the rod. The results from the tests show a increased concrete cracking load as well as a increased steel yielding load. The thesis consists of a main body and three papers. The main body covers a literature survey of some of the work done in the area. Paper A covers tests made with Glass fibre beams combined with concrete, Paper B is about strengthening with Near Surface Mounted Reinforcement with CFRP rods and Paper C covers strengthening with Near Surface Reinforcement CFRP rods where the rods have been prestressed.

Place, publisher, year, edition, pages
Luleå: Luleå tekniska universitet, 2003. , 57 p.
Series
Licentiate thesis / Luleå University of Technology, ISSN 1402-1757 ; 2003:25
Research subject
Structural Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-17561Local ID: 3f95aca0-be01-11db-9be7-000ea68e967bOAI: oai:DiVA.org:ltu-17561DiVA: diva2:990566
Note
Godkänd; 2003; 20070216 (ysko)Available from: 2016-09-29 Created: 2016-09-29Bibliographically approved

Open Access in DiVA

fulltext(4320 kB)11 downloads
File information
File name FULLTEXT01.pdfFile size 4320 kBChecksum SHA-512
affcb656a416fde2bb16b4e65d0fb1de86d6c705230ea33c9e470626daf7d66ba5e0b331311c60a55b0879836b9fb7e9a7d458fa485e6424085acfd0df4fe292
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Nordin, Håkan
By organisation
Structural and Construction Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 11 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 13 hits
ReferencesLink to record
Permanent link

Direct link