The importance of a correct dead time setting in isotope ratio mass spectrometry: implementation of an electronically determined dead time to reduce measurement uncertainty
FOI, Umeå.
FOI, Umeå.
Institute for Reference Materials and Measurements, Geel.
2006 (English)In: International Journal of Mass Spectrometry, ISSN 1387-3806, E-ISSN 1873-2798, Vol. 257, no 1-3, 12-15 p.Article in journal (Refereed) Published
Abstract [en]

Dead time determinations on a mass spectrometry system with ion counting detection can either be done using an isotope ratio measurement approach or via electronic examination of individual components, e.g., the pulse amplifier. Depending on the dead time of each component in the signal chain, the electronically determined result may not represent the true value for the total system, i.e., there might be a series of hardware related dead times. However, a hardware set artificial dead time in the pulse counting system that is long enough might yield a system dead time that can be represented by this set dead time solely. It is shown in this work that a carefully chosen, artificially introduced set dead time yields a system that may be characterized to a much lower uncertainty than is possible using ratio-based measurement approaches. Ultimately, the impact of the dead time on the combined uncertainty of an isotope abundance ratio measurement may be negligible even at very high count rates, i.e., >1 Mcps. In other words, incorporating the dead time contribution in a combined uncertainty calculation would no longer be necessary.

Place, publisher, year, edition, pages
2006. Vol. 257, no 1-3, 12-15 p.
National Category
Physical Chemistry
Research subject
Chemistry of Interfaces
Identifiers
URN: urn:nbn:se:ltu:diva-11982DOI: 10.1016/j.ijms.2006.05.011Local ID: b0957e50-cb24-11db-b3ed-000ea68e967bOAI: oai:DiVA.org:ltu-11982DiVA: diva2:984932
Note
Validerad; 2006; 20070130 (ysko)Available from: 2016-09-29 Created: 2016-09-29 Last updated: 2017-11-24Bibliographically approved

Open Access in DiVA

fulltext(242 kB)103 downloads
File information
File name FULLTEXT01.pdfFile size 242 kBChecksum SHA-512
6f329733039c4012556123d039f1ff181be44f31bc81e685ee0a8c6afea19ce6d1396646720bf2010ec2e8a0ee7abb72e1097d09e3710876b705d39b41ccd145
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Search in DiVA

By author/editor
Baxter, Douglas
In the same journal
International Journal of Mass Spectrometry
Physical Chemistry

Search outside of DiVA

GoogleGoogle Scholar
Total: 103 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 51 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf