Abstract [en]

Today, there is uncertainty about how much the results differ when drying concrete

at 20, 50 and 105 °C prior to saturation of concrete in order to determine the

degree of saturation and hydraulic conductivity. Micro-cracks occur when concrete is

dried at higher temperatures and causes increased hydraulic conductivity. Further, the

concrete is believed not to be completely saturated if not all the physically bound

water, so called free water, has been dried out prior to saturation.

This thesis compares the effect of three different drying temperatures on the

possibility to saturate concrete with water. The work was conducted at Vattenfall’s

concrete laboratory in Älvkarleby. The three drying temperatures were +20 °C

(room temperature), 50 °C and +105 °C. The objective was to determine if

differences on the degree of saturation and hydraulic conductivity were non-existent

or negligible. Vacuum saturation after drying at 105 °C is considered to be complete.

The results after drying at 20 °C and 50 °C were compared to those after drying at

105 °C. The results of the tests indicate that the concrete should be dried at +105°C

prior to saturation with water. Then the risk of frost damage to concrete in hydro

power structures can be assessed.

How determination of the hydraulic conductivity is affected by the drying

temperature gave more vague and dubious results. All specimens showed a maximum

hydraulic conductivity after drying at 50 °C, not after 105 °C as expected. It was

believed that the hydraulic conductivity theoretically would increase because of

(more) micro-cracks when being dried at 105 °C. Results from the concrete with vct

1.0 gave results that indicated that the specimens had been damaged by method 1. To

sum up, the results of the tests indicate that further studies on the effects of drying

temperatures should be made.

Place, publisher, year, edition, pages
2016. , 61 p.
National Category
Marine Engineering Engineering and Technology
Identifiers
URN: urn:nbn:se:uu:diva-302575ISRN: UTH-INGUTB-EX-B-2016/29-SEOAI: oai:DiVA.org:uu-302575DiVA: diva2:958221
Educational program
Bachelor Programme in Construction Engineering
Supervisors
Examiners
Available from: 2016-09-07 Created: 2016-09-06 Last updated: 2016-09-07Bibliographically approved

Open Access in DiVA

Inverkan av torktemperatur vid vattenmättning av bruk och betong(3591 kB)16 downloads
File information
File name FULLTEXT01.pdfFile size 3591 kBChecksum SHA-512
48cc966414de00877de27dcd3ec1fb9ff164110c445c43a21b59ae0563d9d0b91d43a5f4de623241d9d5a4096f119052046f7c1b590658cb3b9fca5ec14b237d
Type fulltextMimetype application/pdf

By organisation
Byggteknik
Marine EngineeringEngineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 16 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 64 hits
ReferencesLink to record
Permanent link

Direct link